Mechanical properties of trabecular bone. Dependency on strain rate
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
The effect of strain rate (epsilon) and apparent density (rho) on stiffness (E), strength (sigma u), and ultimate strain (epsilon u) was studied in 60 human trabecular bone specimens from the proximal tibia. Testing was performed by uniaxial compression to 5% specimen strain. Six different strain rates were used: 0.0001, 0.001, 0.01, 0.1, 1, and 10 s-1. Apparent density ranged between 0.23 and 0.59 g cm-3. Linear and non-linear regression analyses using strength, stiffness and ultimate strain as dependent variables (Y) and strain rate and apparent density as independent variables were performed using the following models: Y = a rho b epsilon c, Y = rho b(a + c epsilon; Y = (a + b rho)epsilon c, Y = a rho 2 epsilon c, E = a rho 3 epsilon c. The variations of strength and stiffness were explained equally well by the linear and the power function relationship to strain rate. The exponent was 0.07 in the power function relationship between strength and strain rate and 0.05 between stiffness and strain rate. The variation of ultimate strain was explained best using a power function relationship to strain rate (exponent = 0.03). The variation of strength and stiffness was explained equally well by the linear, power function and quadratic relationship to apparent density. The cubic relationship between stiffness and apparent density showed a less good fit. Ultimate strain varied independently of apparent density.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [100]
Citations
Cites
(1962) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(62)91145-6 · Cited by 4,391
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical properties of cellular solids
Ashby, M. F., & Medalist, R. F. M. (1983) · Metallurgical Transactions A · doi:10.1007/bf02645546 · Cited by 1,137
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Dynamic response of bone and muscle tissue.
McElhaney, J. H. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1231 · Cited by 509
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
The fabric dependence of the orthotropic elastic constants of cancellous bone
Turner, C. H., Cowin, S. C., Rho, J. Y., Ashman, R. B., & Rice, J. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90048-8 · Cited by 346
Research works printed but not linked: 4
- Cassidy, 1985, Mechanical and architectural properties in bovine cancellous bone, Trans. ORS, 10, 354
- Downey, 1987, Compressive loading raises intraosseous pressure in the femoral head, Trans. ORS, 12, 496
- Harrigan, 1981, The influence of apparent density and trabecular orientation on the elastic modulus of cancellous bone, Trans. ORS, 6, 277
- McElhaney, 1970, A Porous Block Model for Cancellous Bone
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Misch, C. E., Qu, Z., & Bidez, M. W. (1999) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(99)90437-8 · Cited by 509
Load transfer across the pelvic bone
Dalstra, M., & Huiskes, R. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00125-n · Cited by 396
Augat, P., Reeb, H., & Claes, L. E. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110921 · Cited by 328
A 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens
Linde, F., Hvid, I., & Madsen, F. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90255-y · Cited by 233
Self-citationAn Application of Nanoindentation Technique to Measure Bone Tissue Lamellae Properties
Hoffler, C. E., Guo, X. E., Zysset, P. K., & Goldstein, S. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2073671 · Cited by 222
McCALDEN, R. W., McGEOUGH, J. A., & COURT-BROWN, C. M. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199703000-00016 · Cited by 221
Bouxsein, M. L., & Radloff, S. E. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.5.839 · Cited by 200
Age variations in the properties of human tibial travecular bone
Ding, M. L., Dalstra, M., Danielsen, C. C., Kabel, J., Hvid, I., & Linde, F. (1997) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.79b6.7538 · Cited by 181
Self-citationYosibash, Z., Trabelsi, N., & Milgrom, C. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.06.017 · Cited by 170
“1⁄4 2003r1:56 app Linde et al. (1991)”
Oreopithecus was a bipedal ape after all: Evidence from the iliac cancellous architecture
Rook, L., Bondioli, L., Köhler, M., Moyà‐Solà, S., & Macchiarelli, R. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.15.8795 · Cited by 164
Teo, J. C. M., Si-Hoe, K. M., Keh, J. E. L., & Teoh, S. H. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.11.001 · Cited by 161
“01 s 1 (Linde et al., 1991).”
BackgroundStandardizing compression testing for measuring the stiffness of human bone
Zhao, S., Arnold, M. C. A., Ma, S., Abel, R. L., Cobb, J. P., Hansen, U. N., & Boughton, O. R. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.78.bjr-2018-0025.r1 · Cited by 151
Role of Trabecular Microarchitecture in Whole-Vertebral Body Biomechanical Behavior
Fields, A. J., Eswaran, S. K., Jekir, M. G., & Keaveny, T. M. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090317 · Cited by 145
(2005) · PubMed · Cited by 135
Nonlinear Behavior of Trabecular Bone at Small Strains
Morgan, E. F., Yeh, O. C., Chang, W. C., & Keaveny, T. M. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1338122 · Cited by 107
Wilcox, R. K., Allen, D. J., Hall, R. M., Limb, D., Barton, D. C., & Dickson, R. A. (2004) · European Spine Journal · doi:10.1007/s00586-003-0625-9 · Cited by 124
Sevilla, P., Aparicio, C., Planell, J. A., & Gil, F. J. (2006) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2006.08.069 · Cited by 123
Comparison of mechanical properties of human, bovine bone and a new processed bone xenograft
Poumarat, G., & Squire, P. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90051-3 · Cited by 122
Fundamental Biomechanics in Bone Tissue Engineering
Wang, X., Nyman, J. S., Dong, X., Leng, H., & Reyes, M. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02579-2 · Cited by 121
Fu, Q., Rahaman, M. N., Dogan, F., & Bal, B. S. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31051 · Cited by 111
Finite element analysis of the implanted proximal tibia
Taylor, M., Tanner, K. E., & Freeman, M. A. R. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00022-0 · Cited by 111
Jiang, Y., Zhao, J., Augat, P., Ouyang, X., Lü, Y., Majumdar, S., & Genant, H. K. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.11.1783 · Cited by 111
Rubin, P., Rakotomanana, L. R., Leyvraz, P. F., Zysset, P. K., Curnier, A., & Heegaard, J. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90035-d · Cited by 106
Age variations in the properties of human tibial trabecular bone and cartilage
Ding, M. L. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700753749791 · Cited by 102
Vastel, L., Meunier, A., Siney, H., Sedel, L., & Courpied, J.-P. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.067 · Cited by 97
Hay, R., Li, J., & Çelik, K. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2020.106088 · Cited by 96
Novitskaya, E. E., Chen, P., Hamed, E., Jun, L., Lubarda, V. A., Jasiuk, I., & McKittrick, J. M. (2011) · Theoretical and Applied Mechanics · doi:10.2298/tam1103209n · Cited by 93
“Lorenzo and Caffarena (2005) performed steered molecular dynamics (SMD) simulations to obtain the mechanical properties of collagen.”
BackgroundInfluentialPerillo‐Marcone, A., & Taylor, M. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2401177 · Cited by 87
Kelly, N., & McGarry, P. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.11.013 · Cited by 88
“Although not investigated, strain rate effects have been shown to influence on trabecular bone compressive behaviour (Galante et al., 1970; Linde et al., 1991).”
BackgroundEmpirical relationships between bone density and ultimate strength: A literature review
Fleps, I., Bahaloo, H., Zysset, P. K., Ferguson, S. J., Pálsson, H., & Helgason, B. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103866 · Cited by 85
Teo, J. C. M., Si-Hoe, K. M., Keh, J. E. L., & Teoh, S. H. (2006) · Materials Science and Engineering C · doi:10.1016/j.msec.2006.05.003 · Cited by 82
Microarchitectural adaptations in aging and osteoarthrotic subchondral bone issues
Ding, M. L. (2010) · Acta Orthopaedica · doi:10.3109/17453671003619037 · Cited by 76
Garo, A., Arnoux, P., Wagnac, É., & Aubin, C. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0826-z · Cited by 70
Zysset, P. K., Pahr, D. H., Engelke, K., Genant, H. K., McClung, M. R., Kendler, D. L., Recknor, C. P., Kinzl, M., Schwiedrzik, J. J., Museyko, O., et al. (2015) · Bone · doi:10.1016/j.bone.2015.06.025 · Cited by 63
Perillo‐Marcone, A., Alonso-Vázquez, A., & Taylor, M. (2003) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/1025584031000064470 · Cited by 61
“[12] was considered more accurate, as it was generated from experimental tests performed on specimens obtained from proximal tibiae.”
MethodMechanical characterization in shear of human femoral cancellous bone: torsion and shear tests
Bruyère-Garnier, K., Dumas, R., Rumelhart, C., & ARLOT, M. E. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00096-x · Cited by 60
Al-Mahmud, M. R., Shishir, M. K. H., Ahmed, S., Tabassum, S., Sadia, S. I., Sachchu, M. M. H., Tama, R. T., Miah, A. R., & Alam, M. A. (2024) · Journal of Crystal Growth · doi:10.1016/j.jcrysgro.2024.127815 · Cited by 59
Gilchrist, S., Guy, P., & Cripton, P. A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025390 · Cited by 59
Development of the fetal ilium – challenging concepts of bipedality
Cunningham, C. A., & Black, S. M. (2008) · Journal of Anatomy · doi:10.1111/j.1469-7580.2008.01005.x · Cited by 59
“As bone is highly responsive to biomechanical forces (Lanyon, 1974; Currey, 1986; Linde et al. 1991; Turner, 1992; Huiskes et al. 2000), the patterns that are observed passing in welldefined trajectories through the ilium may represent some element of force distribution from these sources.”
BackgroundBlecha, L. D., Zambelli, P., Ramaniraka, N. A., Bourban, P. ‐., Månson, J.-A., & Pioletti, D. P. (2005) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840500322433 · Cited by 59
Review Micromechanical testing of bone trabeculae - potentials and limitations
Lucchinetti, E., Thomann, D., & Danuser, G. M. (2000) · Journal of Materials Science · doi:10.1023/a:1026748913553 · Cited by 59
Failure criterion of collagen fiber: Viscoelastic behavior simulated by using load control data
Wang, J., Parnianpour, M., Shirazi-Adl, A., & Engin, A. E. (1997) · Theoretical and Applied Fracture Mechanics · doi:10.1016/s0167-8442(97)00002-5 · Cited by 55
Ariza, O., Gilchrist, S. E., Widmer, R. P., Guy, P., Ferguson, S. J., Cripton, P. A., & Helgason, B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.11.042 · Cited by 53
Perillo‐Marcone, A., Ryd, L., Johnsson, K., & Taylor, M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.004 · Cited by 53
Boehm, H. F., Raeth, C. W., Monetti, R., Müeller, D., Newitt, D. C., Majumdar, S., Rummeny, E. J., Morfill, G. E., & Link, T. M. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000064782.94757.0f · Cited by 52
Biomechanical characteristics of human trabecular bone
Ouyang, J., Yang, G., Wu, W., Zhu, Q., & Zhong, S. Z. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00035-1 · Cited by 51
Mapping anisotropy of the proximal femur for enhanced image based finite element analysis
Enns-Bray, W. S., Owoc, J. S., Nishiyama, K. K., & Boyd, S. K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.020 · Cited by 52
Design and implementation of a novel mechanical testing system for cellular solids
Nazarian, A., Stauber, M., & Müller, R. (2005) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30232 · Cited by 49
Bone material properties and fracture analysis: Needle insertion for spinal surgery
Teoh, S. H., & Chui, C. K. (2007) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2007.06.004 · Cited by 48
Gravitational and Space Biology
Landis, W. J. (2005) · Cited by 49
Fatigue Microdamage in Bovine Trabecular Bone
Moore, T. L. A., & Gibson, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1631584 · Cited by 47
Ignatius, A. A., Wolf, S., Augat, P., & Claes, L. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200110)57:1<126::aid-jbm1151>3.0.co;2-m · Cited by 45
Kasra, M., & Grynpas, M. D. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.03.008 · Cited by 42
Varga, P., Schwiedrzik, J. J., Zysset, P. K., Hofmann‐Fliri, L., Widmer, D., Gueorguiev, B. G., Blauth, M., & Windolf, M. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.11.026 · Cited by 41
Volpato, V. S., Viola, T. B., Nakatsukasa, M., Bondioli, L., & Macchiarelli, R. (2007) · Primates · doi:10.1007/s10329-007-0053-2 · Cited by 40
“…load magnitude and orientations (e.g., Ruimerman et al. 2005) and that peak principal stress directions align with trabecular trajectories (Linde et al. 1991; Odgaard et al. 1997), the structural reinforcement and the specific cancellous mesh properties detected in Sansuke along the…”
BackgroundStress relaxation of bone significantly affects the pull‐out behavior of pedicle screws
İnceoğlu, S., McLain, R. F., Cayli, S., Kılınçer, C., & Ferrara, L. (2004) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.03.007 · Cited by 40
Gilchrist, S. E., Nishiyama, K. K., de Bakker, P., Guy, P., Boyd, S. K., Oxland, T. R., & Cripton, P. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.06.040 · Cited by 39
“During the fall, the instantaneous value of a femur's compliance influences its displacement rate (in mm/s) and loading rate (in N/s), which in turn alters the bone's mechanical behaviour in a rapid and complex way (Carter and Hayes, 1977; Linde et al., 1991).”
BackgroundOveraker, D. W., Langrana, N. A., & Cuitiño, A. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835085 · Cited by 39
Low elastic modulus metals for joint prosthesis: Tantalum and nickel–titanium foams
Arciniegas, M. P., Aparicio, C., Manero, J. M., & Gil, F. J. (2007) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2007.02.184 · Cited by 38
Prot, M., Cloete, T. J., Saletti, D., & Laporte, S. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.02.021 · Cited by 38
“…studies on the mechanical response of cancellous bone at intermediate strain rates (from 1/s (Halgrin, 2009) to 10/s (Carter and Hayes, 1977; Linde et al., 1991)), there is a general lack of data for this range, which is mainly due to experimental difficulties experienced with traditional…”
BackgroundResultHydraulic Strengthening Affects the Stiffness and Strength of Cortical Bone
Liebschner, M. A. K., & Keller, T. S. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8960-0 · Cited by 38
Effective mechanical properties of diaphyseal cortical bone in the canine femur
Autefage, A., Palierne, S., Charron, C., & Swider, P. (2012) · The Veterinary Journal · doi:10.1016/j.tvjl.2012.04.001 · Cited by 37
Prot, M., Saletti, D., Pattofatto, S., Bousson, V., & Laporte, S. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.002 · Cited by 38
“…with a variation depending, among others, on age (Follet et al., 2011), anatomic localization (Morgan and Keaveny, 2001), and geometry (Linde et al., 1992), studies have recently demonstrated that the characterization of cancellous bone architecture was a good predictor of low strain…”
Low elastic modulus titanium–nickel scaffolds for bone implants
Li, J., Yang, H., Wang, H., & Ruan, J. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.08.043 · Cited by 37
Zhai, X., Gao, J., Nie, Y., Guo, Z., Kedir, N., Claus, B., Sun, T., Fezzaa, K., Xiao, X., & Chen, W. W. (2019) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2019.07.010 · Cited by 36
A multiscale modeling approach to scaffold design and property prediction
Chan, K. S., Liang, W., Francis, W. L., & Nicolella, D. P. (2010) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2010.07.006 · Cited by 34
Amini, M., Nazemi, S. M., Lanovaz, J. L., Kontulainen, S. A., Masri, B. A., Wilson, D. R., Szyszkowski, W., & Johnston, J. D. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.05.011 · Cited by 34
Axial-shear interaction effects on microdamage in bovine tibial trabecular bone
Wang, X., Guyette, J. P., Liu, X., Roeder, R. K., & Niebur, G. L. (2005) · European Journal of Morphology · doi:10.1080/09243860500095570 · Cited by 34
“However, the strain rate used in this study was only 0.2% per second, compared to 0.5% in previous studies (Ford & Keaveny 1996; Keaveny et al. 1994b), which may affect the stiffness (Linde et al. 1991).”
ResultInfluentialAnatomic and Directional Variation in the Mechanical Properties of the Mandibular Condyle in Pigs
Teng, S., & Herring, S. W. (1996) · Journal of Dental Research · doi:10.1177/00220345960750110501 · Cited by 33
Effect of long-term ovariectomy on bone mechanical properties in young female cynomolgus monkeys
Kasra, M., & Grynpas, M. D. (1994) · Bone · doi:10.1016/8756-3282(94)90281-x · Cited by 33
McCarty, C. A., Thomason, J. J., Gordon, K., Burkhart, T. A., Milner, J. S., & Holdsworth, D. W. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159541 · Cited by 32
“The viscoelastic response of bone suggests that the stiffness is also related to the loading rate, in that an increased loading rate has been shown to increase the stiffness of trabecular bone [43].”
BackgroundFracture Stiffness in Callotasis Determined by Dual-Energy X-Ray Absorptiometry Scanning
Tselentakis, G., Owen, P. J., Richardson, J. B., Kuiper, J. H., Haddaway, M. J., Dwyer, J. S. M., & Evans, G. A. (2001) · Journal of Pediatric Orthopaedics B · doi:10.1097/01202412-200107000-00016 · Cited by 31
Keaveny, T. M. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5801-9_2 · Cited by 31
Nazemi, S. M., Amini, M., Kontulainen, S. A., Milner, J. S., Holdsworth, D. W., Masri, B. A., Wilson, D. R., & Johnston, J. D. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.05.002 · Cited by 30
“Fourth, the 2 mm/min experimental testing rate (equivalent to a strain rate of ~0.01/s) was slow and thus viscoelastic effects of bone's fluid phase were ignored (Linde et al., 1991).”
BackgroundInfluentialHigh-speed X-ray visualization of dynamic crack initiation and propagation in bone
Zhai, X., Guo, Z., Gao, J., Kedir, N., Nie, Y., Claus, B., Sun, T., Xiao, X., Fezzaa, K., & Chen, W. W. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.045 · Cited by 27
Huang, H., Tsai, M.-T., Lin, D., Chien, C., & Hsu, J. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2010.02.011 · Cited by 27
Follet, H., Peyrin, F., Vidal-Sallé, E., Bonnassie, A., Rumelhart, C., & Meunier, P. J. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.10.032 · Cited by 27
Dong, X., Yeni, Y. N., Les, C. M., & Fyhrie, D. P. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20108 · Cited by 27
Campbell‐Malone, R. (2007) · Woods Hole Open Access Server (WHOAS) · doi:10.1575/1912/1817 · Cited by 29
Estimation of bone material properties using an inverse finite element method
Garo, A., Arnoux, P., & Aubin, C. (2009) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840903080851 · Cited by 26
“The displacement rate thus influences the material properties of vertebral bones, as it was also found in related published experimental studies (Linde et al. 1991; Kopperdahl and Keaveny 1998; Shim et al. 2005; Hansen et al. 2008).”
ResultIn Vivo Observations of Hydraulic Stiffening in the Canine Femoral Head
Ochoa, J. A., Sanders, A. P., Kiesler, T. W., Heck, D. A., Toombs, J. P., Brandt, K. D., & Hillberry, B. M. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2796051 · Cited by 25
Flexural and Creep Properties of Human Jaw Compact Bone for FEA Studies
Vitins, V., Dobelis, M., Middleton, J., Limbert, G., & Knēts, I. (2003) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840310001637257 · Cited by 25
Ercan, B., & Webster, T. J. (2014) · CRC Press eBooks · doi:10.1201/b17444-8 · Cited by 25
Kasra, M., & Grynpas, M. D. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798311 · Cited by 23
Røhl, L., Linde, F., Odgaard, A., & Hvid, I. (1997) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411971534368 · Cited by 22
Self-citationEffects of loading rate on the of mechanical behavior of the femur in falling condition
Askarinejad, S., Johnson, J. E., Rahbar, N., & Troy, K. L. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.04.038 · Cited by 22
Development of a crushable foam model for human trabecular bone
Soltanihafshejani, N., Bitter, T., Janssen, D. W., & Verdonschot, N. J. J. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.08.009 · Cited by 21
Mechanical Properties of Human Mineralized Connective Tissues
Santis, R. D., Ambrosio, L., Mollica, F., Netti, P. A., & Nicolais, L. (2007) · Birkhäuser Boston eBooks · doi:10.1007/978-0-8176-4411-6_6 · Cited by 21
Bone properties of the humeral head and resistance to screw cutout
Frich, L. H., & Jensen, N. C. (2014) · International Journal of Shoulder Surgery · doi:10.4103/0973-6042.131851 · Cited by 19
“We used the principles of biomechanical testing reported by Linde et al . in the Journal of Biomechanics [12] eliminating as many restraints and biases as possible.”
Jazinizadeh, F., Mohammadi, H., & Quenneville, C. E. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103593 · Cited by 18
Wu, Z. X., Liu, D., Wan, S. Y., Zhang, Y., Lei, W., & Cui, G. (2011) · Journal of Orthopaedic Science · doi:10.1007/s00776-010-0019-x · Cited by 18
“intact within the trabecular spaces [21].”
Waletzko‐Hellwig, J., Saemann, M., Schulze, M., Frerich, B., Bader, R., & Dau, M. (2021) · Materials · doi:10.3390/ma14051069 · Cited by 17
(1997) · Cellular Solids · doi:10.1017/cbo9781139878326.013 · Cited by 16
Tian, T., Huang, H., Wang, Z., Shi, B., Zheng, Q., & Li, C. (2022) · BioMedical Engineering OnLine · doi:10.1186/s12938-022-01000-y · Cited by 16
The Effect of Damage on the Viscoelastic Behavior of Human Vertebral Trabecular Bone
Bredbenner, T. L., & Davy, D. T. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2205370 · Cited by 16
Strain rate dependency of bovine trabecular bone under impact loading at sideways fall velocity
Enns-Bray, W. S., Ferguson, S. J., & Helgason, B. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.04.042 · Cited by 15
Developments in Modelling Bone Screwing
Wilkie, J. A., Docherty, P. D., & Möller, K. (2020) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2020-3029 · Cited by 15
“In contrast, bone has shown significant strain rate dependence [12].”
Metadata
- Authors
- Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K.
- Affiliations
- Aarhus University Hospital (DK)
- ORCID
- Odgaard, Anders
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 24
- Issue
- 9
- Pages
- 803-809
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2143367764
- Semantic Scholar
- 72af2a7e4a64ff6fc5f5338e1d8643c10f9addaa
- Cited by
- 171
- References
- 41
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 5 · 2021: 3 · 2020: 9 · 2019: 9 · 2018: 3 · 2017: 3 · 2016: 4 · 2015: 7 · 2014: 9 · 2013: 6 · 2012: 6
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, strain rate, apparent density, stiffness, ultimate strength, ultimate strain, uniaxial compression, power function relationship, proximal tibia
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Epiphyses, Humans, Knee Joint, Male, Tensile Strength, Tibia, Bone Density, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.