Mechanical properties of trabecular bone. Dependency on strain rate
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
The effect of strain rate (epsilon) and apparent density (rho) on stiffness (E), strength (sigma u), and ultimate strain (epsilon u) was studied in 60 human trabecular bone specimens from the proximal tibia. Testing was performed by uniaxial compression to 5% specimen strain. Six different strain rates were used: 0.0001, 0.001, 0.01, 0.1, 1, and 10 s-1. Apparent density ranged between 0.23 and 0.59 g cm-3. Linear and non-linear regression analyses using strength, stiffness and ultimate strain as dependent variables (Y) and strain rate and apparent density as independent variables were performed using the following models: Y = a rho b epsilon c, Y = rho b(a + c epsilon; Y = (a + b rho)epsilon c, Y = a rho 2 epsilon c, E = a rho 3 epsilon c. The variations of strength and stiffness were explained equally well by the linear and the power function relationship to strain rate. The exponent was 0.07 in the power function relationship between strength and strain rate and 0.05 between stiffness and strain rate. The variation of ultimate strain was explained best using a power function relationship to strain rate (exponent = 0.03). The variation of strength and stiffness was explained equally well by the linear, power function and quadratic relationship to apparent density. The cubic relationship between stiffness and apparent density showed a less good fit. Ultimate strain varied independently of apparent density.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [100]
Citations
Cites
(1962) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(62)91145-6 · Cited by 4,391
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical properties of cellular solids
Ashby, M. F., & Medalist, R. F. M. (1983) · Metallurgical Transactions A · doi:10.1007/bf02645546 · Cited by 1,137
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Dynamic response of bone and muscle tissue.
McElhaney, J. H. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1231 · Cited by 509
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
The fabric dependence of the orthotropic elastic constants of cancellous bone
Turner, C. H., Cowin, S. C., Rho, J. Y., Ashman, R. B., & Rice, J. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90048-8 · Cited by 346
Limitations of the continuum assumption in cancellous bone
Harrigan, T. P., Jasty, M., Mann, R. W., & Harris, W. H. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90257-6 · Cited by 305
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
Mechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Brown, T. D., & Ferguson, A. B. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990819 · Cited by 282
Elastic properties of cancellous bone: Measurement by an ultrasonic technique
Ashman, R. B., Corin, J. D., & Turner, C. H. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90327-7 · Cited by 227
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Self-citationAnatomical variation of orthotropic elastic moduli of the proximal human tibia
Ashman, R. B., Rho, J. Y., & Turner, C. H. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90073-0 · Cited by 184
The effect of constraint on the mechanical behaviour of trabecular bone specimens
Linde, F., & Hvid, I. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90209-1 · Cited by 181
Self-citationIV. On the elastic equilibrium of circular cylinders under certain practical systems of load
Filon, L. N. G. (1902) · Philosophical Transactions of the Royal Society of London Series A Containing Papers of a Mathematical or Physical Character · doi:10.1098/rsta.1902.0004 · Cited by 179
Elastic and viscoelastic properties of trabecular bone: Dependence on structure
Pugh, J. W., Rose, R. M., & Radin, E. L. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90006-7 · Cited by 177
Variations in strength and structure of cancellous bone at the knee
Behrens, J. C., Walker, P. S., & Shoji, H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90010-4 · Cited by 171
Mechanical properties of human cancellous bone in the femoral head
Schoenfeld, C. M., Lautenschlager, E. P., & Meyer, P. R. (1974) · Medical & Biological Engineering & Computing · doi:10.1007/bf02477797 · Cited by 167
Biomechanics: Current Interdisciplinary Research
Perren, S. M., & Schneider, E. (1985) · Springer eBooks · doi:10.1007/978-94-011-7432-9 · Cited by 150
Hvid, I., Bentzen, S. M., Linde, F., Mosekilde, L., & Pongsoipetch, B. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90067-5 · Cited by 144
Self-citationBiomechanical Studies of the Musculo‐Skeletal System
(1962) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1962.tb20236.x · Cited by 126
The mechanical behaviour of intracondylar cancellous bone of the femur at different loading rates
Ducheyne, P., Heymans, L., Martens, M. A., Aernoudt, E., Meester, P. J. D., & Mulier, J. C. (1977) · Journal of Biomechanics · doi:10.1016/0021-9290(77)90089-6 · Cited by 104
The limitations of canine trabecular bone as a model for human: A biomechanical study
Kuhn, J. L., Goldstein, S. A., Ciarelli, M. J., & Matthews, L. S. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90032-8 · Cited by 104
Energy absorptive properties of human trabecular bone specimens during axial compression
Linde, F., Hvid, I., & Pongsoipetch, B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070316 · Cited by 103
Self-citationMechanical Properties of Trabecular Bone by a Non-Destructive Compression Testing Approach
Linde, F., Gøosthgen, C. B., Hvid, I., Pongsoipetch, B., & Bentzen, S. (1988) · Engineering in Medicine · doi:10.1243/emed_jour_1988_017_008_02 · Cited by 100
Self-citationMaterial properties of femoral cancellous bone in axial loading: Part II: Time dependent properties
Zilch, H., Rohlmann, A., Bergmann, G., & K�lbel, R. (1980) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00380706 · Cited by 91
Effects of Structural Variation on Young's Modulus of Non-Human Cancellous Bone
Hodgskinson, R., & Currey, J. D. (1990) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/pime_proc_1990_204_227_02 · Cited by 88
Resistance of copper and copper alloys to homogeneous deformation in compression
Cook, M. M., & Larke, E. C. (1945) · Cited by 75
Density and Temperature Effects on Some Mechanical Properties of Cancellous Bone
Brear, K., Currey, J. D., Raines, S. A., & Smith, K. (1988) · Engineering in Medicine · doi:10.1243/emed_jour_1988_017_043_02 · Cited by 55
Regional differences in some physical properties of human spongy bone
Evans, F. G., & King, A. I. (1961) · Cited by 52
Is bone hydraulically strengthened?
Swanson, S. A. V., & Freeman, M. A. R. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476165 · Cited by 51
Power Law Models for the Mechanical Properties of Cancellous Bone
Currey, J. D. (1986) · Engineering in Medicine · doi:10.1243/emed_jour_1986_015_039_02 · Cited by 47
Material Properties of Cancellous Bone in Repetitive Axial Loading
Linde, F., Hvid, I., & Jensen, N. C. (1985) · Engineering in Medicine · doi:10.1243/emed_jour_1985_014_042_02 · Cited by 32
Self-citationOn the interaction between specimen and testing machine in mechanical testing procedures
Vrijhoef, M. M. A., & Driessens, F. C. M. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90029-7 · Cited by 19
Klever, F. J., Klumpert, R., Horenberg, J., Grootenboer, H. J., van Campen, D. H., & Pauly, T. (1985) · Springer eBooks · doi:10.1007/978-94-011-7432-9_19 · Cited by 13
The effect of specimen size and geometry on the mechanical behaviour of trabecular bone specimens
Linde, F., Hvid, I., & Madsen, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90046-p · Cited by 10
Self-citationMicrocomputer-based period and amplitude analysis of the electroencephalogram
Salb, J. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443385 · Cited by 9
Predicting the mechanical behavior of bone
Keller, T. S., & Spengler, D. M. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90045-o · Cited by 6
Research works printed but not linked: 4
- Cassidy, 1985, Mechanical and architectural properties in bovine cancellous bone, Trans. ORS, 10, 354
- Downey, 1987, Compressive loading raises intraosseous pressure in the femoral head, Trans. ORS, 12, 496
- Harrigan, 1981, The influence of apparent density and trabecular orientation on the elastic modulus of cancellous bone, Trans. ORS, 6, 277
- McElhaney, 1970, A Porous Block Model for Cancellous Bone
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Misch, C. E., Qu, Z., & Bidez, M. W. (1999) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(99)90437-8 · Cited by 509
Load transfer across the pelvic bone
Dalstra, M., & Huiskes, R. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00125-n · Cited by 396
Augat, P., Reeb, H., & Claes, L. E. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110921 · Cited by 328
Metadata
- Authors
- Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K.
- Affiliations
- Aarhus University Hospital (DK)
- ORCID
- Odgaard, Anders
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 24
- Issue
- 9
- Pages
- 803-809
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2143367764
- Cited by
- 171
- References
- 41
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 5 · 2021: 3 · 2020: 9 · 2019: 9 · 2018: 3 · 2017: 3 · 2016: 4 · 2015: 7 · 2014: 9 · 2013: 6 · 2012: 6
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, strain rate, apparent density, stiffness, ultimate strength, ultimate strain, uniaxial compression, power function relationship, proximal tibia
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Epiphyses, Humans, Knee Joint, Male, Tensile Strength, Tibia, Bone Density, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.