Cyclic mechanical property degradation during fatigue loading of cortical bone
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Fatigue damage accumulation has been demonstrated in living bone and postulated as a stimulus to the bone modeling and remodeling response. Mechanical property degradation is one manifestation of fatigue damage accumulation. This study examines changes in secant modulus and cyclic energy dissipation behavior during axial load-controlled fatigue loading of cortical bone specimens. The findings suggest that secant modulus degradation and cyclic energy dissipation are greatly increased at loading levels above critical damage strain thresholds of 2500 and 4000 mu epsilon in tensile and compressive fatigue, respectively. Tensile and compressive fatigue loading also caused different forms of modulus degradation at loading levels above these thresholds. Bone behaves as a linear viscoelastic material below these thresholds, even after prior property degradation at higher loading levels. Cyclic energy dissipation was proportional to the 2.1 power of the applied effective strain range for all loadings below 2500 mu epsilon. Above 2500 mu epsilon, tensile fatigue loading caused cyclic energy dissipation proportional to the 5.8 power of the applied effective strain range. Compressive fatigue loading dissipated cyclic energy proportional to the 4.9 power of applied effective strain range over 4000 mu epsilon. Lifetime energy dissipation over all fatigue tests to fracture at a single loading level was well fitted by the same power law in the number of cycles to failure raised to the 0.6 power. Loading levels of 2500 mu epsilon in tension and 4000 mu epsilon in compression are within the ranges observed in living animals, and thus these phenomena may play a role in initiating the remodeling response in live bone tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Fatigue loading results in progressive degradation of mechanical properties such as fracture toughness, modulus, and strength (20, 21).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [20]
Citations
Cites
The Mechanical Adaptations of Bones
Currey, J. D. (1984) · Princeton University Press eBooks · doi:10.1515/9781400853724 · Cited by 896 · cited 1×
“This increased energy dissipation in tensile fatigue may aid in stimulating the preferential remodeling response of bone to tensile loading (Currey, 1984).”
BackgroundStatic vs dynamic loads as an influence on bone remodelling
Lanyon, L. E., & Rubin, C. T. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90003-4 · Cited by 887
Humeral hypertrophy in response to exercise
Jones, H., Priest, J., Hayes, W., Tichenor, C., & Nagel, D. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759020-00012 · Cited by 824
Bone remodeling in response to in vivo fatigue microdamage
Burr, D. B., Martin, R. B., Schaffler, M. B., & Radin, E. L. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90204-0 · Cited by 765 · cited 3×
“Since compact bone is capable of responding to damage accumulation well before specimen fracture (Burr et al., 1985; Martin and Burr, 1982), the prefailure response of compact bone to applied fatigue loading may be of greater clinical relevance than the factors affecting fatigue life.”
BackgroundThe mechanical properties of bone.
Evans, F. G. (1969) · PubMed · Cited by 587
Rubin, C. T., & Lanyon, L. E. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050217 · Cited by 519 · cited 1×
“…correspond well to hypothesized thresholds for remodeling responses in living bone (Burr et al., 1989; Carter, 1987; Cowin, 1986; Frost, 1986; Lanyon, 1987; Lanyon and Rubin, 1984; Rubin and Lanyon 1987) and to the highest strain levels seen in living bone (Bieweiner, 1991; Nunamaker et al., 1990).”
BackgroundMechanical loading history and skeletal biology
Carter, D. R. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90027-3 · Cited by 511 · cited 3×
“In order to model these results, many investigators have advanced the view that mechanical loading is crucial to the maintenance and development of the skeleton (Carter, 1987; Frast.”
BackgroundResultSelf-citationLanyon, L. E. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90026-1 · Cited by 446 · cited 3×
“Peak strains of 1500-2500~ have been commonly observed in a variety of studies (Carter et al., 1981; Lanyon, 1987).”
BackgroundWolff’s Law of Trabecular Architecture at Remodeling Equilibrium
Cowin, S. C. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138584 · Cited by 425 · cited 2×
“…observed in this study correspond well to hypothesized thresholds for remodeling responses in living bone (Burr et al., 1989; Carter, 1987; Cowin, 1986; Frost, 1986; Lanyon, 1987; Lanyon and Rubin, 1984; Rubin and Lanyon 1987) and to the highest strain levels seen in living bone…”
ResultThe effect of prolonged physical training on the properties of long bone: a study of Wolff's Law.
Woo, S. L., Kuei, S. C., Amiel, D., Gomez, M. A., Hayes, W. C., White, F. C., & Akeson, W. H. (1981) · PubMed · Cited by 421
Research works printed but not linked: 2
- Akhter, 1993, Demonstration of fatigue damage effects in rat tibiae, Vol. 18, 197
- Dabastani, 1990, Effect of orientation, strain rate, and temperature on anelasticity of human compact bone, Vol. 2, 104
Cited by
Items 101–200 of 487
Multiple scale modeling for cortical bone fracture in tension using X-FEM
Budyn, É., & Hoc, T. (2007) · European Journal of Computational Mechanics · doi:10.3166/remn.16.213-236 · Cited by 66
Bone stress in runners with tibial stress fracture
Meardon, S. A., Willson, J. D., Gries, S. R., Kernozek, T. W., & Derrick, T. R. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.07.012 · Cited by 65
“demonstrated a threshold of 2500 με for tension and 4000 με for compression before human cortical bone of the femur begins to show signs of microdamage accumulation (Pattin et al., 1996).”
BackgroundA bone remodelling model including the directional activity of BMUs
Martínez‐Reina, J., García‐Aznar, J. M., Domínguez, J., & Doblaré, M. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0122-5 · Cited by 64
“where ∆dA is calculated by means of the experimental curves obtained by Pattin et al. (1996) in uniaxial fatigue tests.”
MethodMechanical behavior of bovine periodontal ligament under tension‐compression cyclic displacements
Shibata, T., Botsis, J., Bergomi, M., Mellal, A., & Komatsu, K. (2006) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2006.00269.x · Cited by 63
Fatigue of Bovine Trabecular Bone
Moore, T. L. A., & Gibson, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1631583 · Cited by 56
The resistance of cortical bone tissue to failure under cyclic loading is reduced with alendronate
Bajaj, D., Geissler, J. R., Allen, M. R., Burr, D. B., & Fritton, J. C. (2014) · Bone · doi:10.1016/j.bone.2014.03.045 · Cited by 54
“[31–35] Further, in a well-controlled dog model, increases in the average length of micro-cracks with bisphosphonate treatment versus saline control were evident within cortical bone after three years.”
Chang, T.-W., Yang, C., Liu, Y., Chen, W., Lin, K., Lai, Y., Huang, C., Lu, Y., & Cheng, C. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.05.007 · Cited by 59
Arndt, T., Westblad, P., Ekenman, I., & Lundberg, A. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00191-1 · Cited by 59
“In vitro simulations of gait [1,2,13] and model calculations of MTII bending [14] have concentrated upon dorsal compression strain, although secant modulus degradation in cortical bone has been found to occur both at tensile strains over 2500 mo and compressive strains greater than 4000 mo [15].”
BackgroundFleck, C., & Eifler, D. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00364-0 · Cited by 59
“The property changes observed during fatigue loading are caused by the accumulation of internal microdamage (Burr et al., 1998; Carter and Caler, 1985; Fleck and Eifler, 1994; Fleck, 1996; Pattin et al., 1996; Zioupos and Currey, 1994).”
BackgroundWong, J., Steklov, N., Patil, S. S., Flores‐Hernandez, C., KESTER, M. A., Colwell, C. W., & DʼLima, D. D. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21221 · Cited by 57
“4% strain.(21) We therefore computed the volume of cortical bone above this damage threshold, which reflected the variation among the specimens (Fig.”
BackgroundMethodHambli, R. (2011) · Finite Elements in Analysis and Design · doi:10.1016/j.finel.2011.02.014 · Cited by 57
“Bone fatigue damage of trabecular bone was investigated experimentally by several authors with negligible observed effects of heat dissipation [26–29].”
BackgroundScaling of maximum net force output by motors used for locomotion
Marden, J. H. (2005) · Journal of Experimental Biology · doi:10.1242/jeb.01483 · Cited by 57
“The most thoroughly tested biological material is bone, which in uniaxial tensile or compression shows a b of about 11 (calculated from data in Pattin et al., 1996).”
BackgroundSchaffler, M. B. (2000) · International Journal of Fatigue · doi:10.1016/s0142-1123(00)00053-0 · Cited by 58
Experimental investigation of bone remodelling using composite femurs
Waide, V., Cristofolini, L., Stolk, J. N., Verdonschot, N. J. J., & Toni, A. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(03)00072-x · Cited by 55
“to a degradation of the mechanical properties of cortical bone, a possible stimulus for bone remodelling (Pattin et al., 1996).”
BackgroundBurr-like, laser-made 3D microscaffolds for tissue spheroid encagement
Danilevičius, P., Rezende, R. A., Pereira, F. D. A. S., Selimis, A., Kasyanov, V. A., Noritomi, P. Y., da Silva, J. V. L., Chatzinikolaidou, Μ., Farsari, M., & Mironov, V. A. (2015) · Biointerphases · doi:10.1116/1.4922646 · Cited by 52
On the role of bone damage in calcium homeostasis
Martínez‐Reina, J., García‐Aznar, J. M., Domínguez, J., & Doblaré, M. (2008) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2008.06.007 · Cited by 53
Shah, S. S., Gentile, J. M., Chen, X., Kontaxis, A., Dines, D. M., Warren, R. F., Taylor, S. A., Jahandar, A., & Gulotta, L. V. (2020) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2020.04.004 · Cited by 51
Structural and mechanical effects of in vivo fatigue damage induction on murine tendon
Sereysky, J. B., Andarawis‐Puri, N., Jepsen, K. J., & Flatow, E. L. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.22012 · Cited by 49
“The maintenance of function despite significant changes to structure is similar to the behavior of other musculoskeletal tissue, such as bone.(12) However, the cells within bone respond to changes in structure(13) while those of tendon may not,(1) allowing tendinosis to develop.”
BackgroundAbdel-Sayed, P., Darwiche, S., Kettenberger, U., & Pioletti, D. P. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.048 · Cited by 49
“Actually, the latter consider tensile and compressive strains identically, while dissipative formulations gave a better fitting of the experimental data in tension, which were different than in compression [41].”
BackgroundExperimental investigation of Poisson's ratio as a damage parameter for bone fatigue
Pidaparti, R. M. V., & Vogt, A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1243 · Cited by 50
Fatigue characterization of a hydroxyapatite-reinforced polyethylene composite. I. Uniaxial fatigue
That, P. T. T., Tanner, K. E., & Bonfield, W. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<453::aid-jbm20>3.0.co;2-q · Cited by 50
Jerban, S., Ma, Y., Nazaran, A., Dorthé, E. W., Cory, E., Carl, M., DʼLima, D. D., Sah, R. L., Chang, E. Y., & Du, J. (2018) · NMR in Biomedicine · doi:10.1002/nbm.3994 · Cited by 48
Fatigue Microdamage in Bovine Trabecular Bone
Moore, T. L. A., & Gibson, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1631584 · Cited by 47
Cortical bone fracture analysis using XFEM – case study
Idkaidek, A., & Jasiuk, I. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2809 · Cited by 47
“4% is used as a failure criterion [18, 19] as described in Equation 2.”
MethodInelastic Strain Accumulation in Cortical Bone During Rapid Transient Tensile Loading
Fondrk, M. T., Bahniuk, E., & Davy, D. T. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800862 · Cited by 48
An energy dissipation-based model for damage stimulated bone adaptation
Levenston, M. E., & Carter, D. R. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00039-6 · Cited by 48
Self-citationMechanical properties of open-cell foam synthetic thoracic vertebrae
Johnson, A. E., & Keller, T. S. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3158-7 · Cited by 46
Model of flexural fatigue damage accumulation for cortical bone
Griffin, L. V., Gibeling, J. C., Martin, R. B., Gibson, V. A., & Stover, S. M. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150418 · Cited by 42
“on uniaxial tension and compression fatigue for human femoral tissue (17).”
BackgroundMethodInfluentialPalissery, V., Taylor, M., & Browne, M. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/b:jmsm.0000010098.65572.3b · Cited by 45
Hambli, R. (2010) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.1413 · Cited by 44
Taylor, S. A., Shah, S. S., Chen, X., Gentile, J. M., Gulotta, L. V., Dines, J. S., Dines, D. M., Cordasco, F. A., Warren, R. F., & Kontaxis, A. (2020) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.19.01118 · Cited by 44
Finite Element Simulation of the Fatigue Behaviour of Cancellous Bone*
Taylor, M., Cotton, J. R., & Zioupos, P. (2002) · Meccanica · doi:10.1023/a:1020848007201 · Cited by 44
“In previous experimental studies reporting modulus degradation of cortical bone [2, 4 ], uniaxial loading was used to perform their fatigue tests.”
BackgroundMethodPeriprosthetic fractures after medial unicompartmental knee arthroplasty: a narrative review
Thoreau, L., Marfil, D. M., & Thienpont, E. (2021) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-021-04063-z · Cited by 43
Wong, C., Hu, H., Hsieh, M.-P., & Huang, K. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00154 · Cited by 43
“On the other hand, cyclic strain energy during repetitive motion is related to fatigue of the material and therefore the strain energy of the IVD may be interpreted as the susceptibility to chronic disc degeneration (Pattin et al., 1996).”
BackgroundCreep Does Not Contribute to Fatigue in Bovine Trabecular Bone
Moore, T. L. A., O’Brien, F. J., & Gibson, L. J. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1762892 · Cited by 37
Age and gender effects on bone mass density variation: finite elements simulation
Barkaoui, A., Kahla, R. B., Merzouki, T., & Hambli, R. (2016) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-016-0834-x · Cited by 43
“The damage can reach a maximum value of up to 1, corresponding to material failure, and can be described using failure cycle’s number N f given by the following equation (Pattin et al. 1996; Martin et al. 1998; Martin 2003):”
BackgroundExternal bone remodeling through boundary elements and damage mechanics
Martínez, G., García‐Aznar, J. M., Doblaré, M., & Cerrolaza, M. (2006) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2006.06.014 · Cited by 43
“[27] showed that the micro-strain range that makes this variable activate itself is between 2500 and 3200 micro-strain in traction and 2500 and 4000 in compression.”
BackgroundOn the modelling bone tissue fracture and healing of the bone tissue.
Doblaré, M., & García, J. M. (2003) · PubMed · Cited by 43
Winwood, K. L., Zioupos, P., Currey, J. D., Cotton, J. R., & Taylor, M. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30796 · Cited by 42
Bone Material Properties and Skeletal Fragility
Fyhrie, D. P., & Christiansen, B. (2015) · Calcified Tissue International · doi:10.1007/s00223-015-9997-1 · Cited by 41
A coupled mechano-biochemical model for bone adaptation
Klika, V., Pérez, M. Á., García‐Aznar, J. M., Maršík, F., & Doblaré, M. (2013) · Journal of Mathematical Biology · doi:10.1007/s00285-013-0736-9 · Cited by 40
“Pattin et al. (1996) measured also the loss of stiffness [or equivalently dam through its definition (10)] as a function of strain applied and of the number of cycles.”
BackgroundMethodInfluentialAnalysis of creep strain during tensile fatigue of cortical bone
Cotton, J. R., Zioupos, P., Winwood, K. L., & Taylor, M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00063-0 · Cited by 40
“This has been depicted in reports of tensile fatigue studies and called, in various reports, ‘‘strain drift’’ (Pattin et al., 1996), ‘‘plastic strain’’ (Taylor et al.”
Silva, M. J., & Touhey, D. C. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20320 · Cited by 35
“In general, the shapes of the degradation curves were similar to those reported for compressive fatigue of human cortical bone.(28) BONE FORMATION AFTER DAMAGING IN VIVO FATIGUE LOADING 257”
ResultIntegrated remodeling-to-fracture finite element model of human proximal femur behavior
Hambli, R., Lespessailles, É., & Benhamou, C.-L. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.08.011 · Cited by 39
Modeling Linear Vibration of Cell Nucleus in Low Intensity Ultrasound Field
Or, M., & Kimmel, E. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.11.011 · Cited by 38
Haider, I. T., Baggaley, M., & Edwards, W. B. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4044034 · Cited by 37
Agcaoglu, S., & Akkuş, O. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4024134 · Cited by 37
“Monitoring the degradation in compliance-derived secant modulus may be another way to assess the state of damage during fatigue [20].”
BackgroundThe aging cortex: to crack or not to crack
Jepsen, K. J. (2003) · Osteoporosis International · doi:10.1007/s00198-003-1475-3 · Cited by 37
“001%/s (tension)* 150 [31] Rate = 1%/sec (tension)* 220 [31] Fatigue strength (compression) 89 [32] Fatigue strength (tension) 55 [32] Creep 63 [33] Age: 35 year old (tension) 170 [6] Age: 85 year old (tension) 144 [6]”
Numerical modelling of impact fracture of cortical bone tissue using X-FEM
Abdelwahab, A. A., & Silberschmidt, V. V. (2011) · University of Birmingham Research Portal (University of Birmingham) · Cited by 36
Two-time scale fatigue modelling: application to damage
Devulder, A., Aubry, D., & Puel, G. (2010) · Computational Mechanics · doi:10.1007/s00466-010-0476-2 · Cited by 37
“Other authors, like Pattin [3] and Kachanov [16], have proposed different evolution models, which could be used with the following method of time homogenization as well.”
BackgroundMartínez‐Reina, J., Calvo‐Gallego, J. L., & Pivonka, P. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.635056 · Cited by 36
“Experimental fatigue tests provide the evolution of d with the strain or the stress level and the number of cycles (Pattin et al., 1996), as well as fatigue life, Nf , which is typically given by expressions such as:”
BackgroundThe red-eared slider turtle carapace under fatigue loading: The effect of rib–suture arrangement
Achrai, B., & Wagner, H. D. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.04.040 · Cited by 35
Mulvihill, B. M., & Prendergast, P. J. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.01.006 · Cited by 35
Osteoporoses: A Rationale for Further Definitions?
Frost, H. M. (1998) · Calcified Tissue International · doi:10.1007/s002239900399 · Cited by 35
“As strains only double in that range, microdamage increases well over 400 times [15].”
BackgroundHip resurfacing increases bone strains associated with short‐term femoral neck fracture
Long, J. P., Santner, T. J., & Bartel, D. L. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20884 · Cited by 35
Kim, D., Shertok, D., Tee, B. C., & Yeni, Y. N. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.03.025 · Cited by 34
“Pattin et al. (1996) suggested that 4000 με in compression is within a strain range to trigger bone remodeling (Pattin et al.”
InfluentialWinwood, K. L., Zioupos, P., Currey, J. D., Cotton, J. R., & Taylor, M. (2006) · PubMed · Cited by 34
Miller, R. H., & Hamill, J. (2009) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802695437 · Cited by 34
“It is therefore unknown how these estimated loads compare to the strength of cortical bone in cyclical loading (Carter et al. 1981; Pattin et al. 1996).”
BackgroundThe effect of osteoporosis treatments on fatigue properties of cortical bone tissue
Brock, G. R., Chen, J. T., Ingraffea, A. R., MacLeay, J., Pluhar, G. E., Boskey, A. L., & van der Meulen, M. C. H. (2015) · Bone Reports · doi:10.1016/j.bonr.2014.10.004 · Cited by 33
“In laboratory fatigue conditions in bending, damage creation starts at 2500 με in regions under tension; however, greater than 4000 με is necessary in the regions under compression (Pattin et al., 1996).”
BackgroundInfluentialDamage analysis of human cortical bone under compressive and tensile loadings
Maghami, E., Moore, J. P., Josephson, T. O., & Najafi, A. R. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.2023135 · Cited by 33
“It was observed that cortical bone shows a higher critical damage threshold in compression than in tension (Pattin et al. 1996; Vashishth et al. 2001).”
BackgroundThe Role of Lower-Limb Geometry in the Pathophysiology of Atypical Femoral Fracture
Haider, I. T., Schneider, P., & Edwards, W. B. (2019) · Current Osteoporosis Reports · doi:10.1007/s11914-019-00525-x · Cited by 33
Age-related differences in the morphology of microdamage propagation in trabecular bone
Green, J. O., Wang, J., Diab, T., Vidaković, B., & Guldberg, R. E. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.08.006 · Cited by 33
“005 and frequency of 2 Hz (Caler and Carter, 1989; Pattin et al., 1996; Moore and Gibson, 2003).”
Ojanen, X., Tanska, P., Malo, M. K. H., Isaksson, H., Väänänen, S. P., Koistinen, A. P., Grassi, L., Magnusson, S. P., Ribel-Madsen, S. M., Korhonen, R. K., et al. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.10.002 · Cited by 32
“However, repeated loading over time may cause cumulative damage or micro cracks in the bone (Pattin et al., 1996).”
BackgroundJoo, W., Jepsen, K. J., & Davy, D. T. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.01.005 · Cited by 33
“To address these issues conducted an experimental study using a protocol based on previous studies to observe tensile damage effects on cortical bone, in terms of changes of stiffness, viscous relaxation and energy dissipation (Jepsen and Davy, 1997; Jepsen et al., 2001; Pattin et al., 1996).”
BackgroundMethodSensitivity of Multiple Damage Parameters to Compressive Overload in Cortical Bone
Morgan, E. F., Lee, J. J., & Keaveny, T. M. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1933916 · Cited by 34
Kondo, T., & Wakabayashi, N. (2009) · Journal of Dentistry · doi:10.1016/j.jdent.2009.03.015 · Cited by 32
Biocomposites: micromechanics of biological hard tissues
Currey, J. D. (1996) · Current Opinion in Solid State and Materials Science · doi:10.1016/s1359-0286(96)80038-6 · Cited by 31
Bone Fatigue and Remodeling in the Development of Stress Fractures
Schaffler, M. B. (2000) · Exercise physiology/CRC series in exercise physiology · doi:10.1201/9781420042191.ch11 · Cited by 32
Influence of phase angle between axial and torsional loadings on fatigue fractures of bone
George, W. T., & Vashishth, D. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.008 · Cited by 30
“Use of bovine bone instead of human is not expected to be a major limitation of this study because both human and bovine bone display similar ratios of monotonic strength under torsional, tensile and compressive loads (1:2:3) which, in turn, are known to influence damage threshold and fatigue life of cortical bone (Ce…”
BackgroundGeissler, J. R., Bajaj, D., & Fritton, J. C. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.01.032 · Cited by 30
“…compromise mechanical integrity, tend to be restricted to more densely-mineralized older-bone tissue and are capable of signaling the remodeling process (Burr et al., 1998; Carter et al., 1976; Hoshaw et al., 1997; Parfitt, 2002; Pattin et al., 1996; Qiu et al., 2005; Schaffler et al., 1990).”
BackgroundFracture analysis of multi-osteon cortical bone using XFEM
Idkaidek, A., Korić, S., & Jasiuk, I. (2017) · Computational Mechanics · doi:10.1007/s00466-017-1491-3 · Cited by 30
Januddi, F., Harun, M. N., Kadir, M. R. A., Abdullah, J., Kamarul, T., Öchsner, A. Ö., & Syahrom, A. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1305-8 · Cited by 30
Turnbull, T. L., Gargac, J. A., Niebur, G. L., & Roeder, R. K. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.06.032 · Cited by 31
“The accumulation of microdamage in machined specimens in vitro has been shown to adversely affect mechanical properties, including the elastic modulus (Schaffler et al., 1989; Pattin et al., 1996) and fracture toughness (Norman et al.”
BackgroundMartínez‐Reina, J., Calvo‐Gallego, J. L., Martin, M., & Pivonka, P. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.886579 · Cited by 29
“The experimental tests perfomed by Pattin et al. (Pattin et al., 1996) included an estimation of fatigue life, N f , which was related to the deformation by the following expression: where K f was assumed constant and equal to 1.445 · 10 53 in tension.”
InfluentialRavandi, M. R. M., Dezianian, S., Talati-Ahmad, M., Ghoddosian, A., & Azadi, M. (2023) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2023.127515 · Cited by 29
Maruyama, N., Shibata, Y., Mochizuki, A., Yamada, A., Maki, K., Inoue, T., Kamijo, R., & Miyazaki, T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.01.004 · Cited by 29
Parkinson, R., & Callaghan, J. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.007 · Cited by 29
“The fatigue behaviour of isolated bone has been studied under both tensile and compressive cyclic loading (Bowman et al., 1998; Caler and Carter, 1989; Carter and Caler, 1983, 1985; Carter and Hayes, 1976; Ganguly et al., 2004; Haddock et al., 2004; Lu et al., 2004; Michel et al., 1993; Moore et al., 2004; Moore and G…”
BackgroundMethodRitchie, R. O., Kinney, J. H., Kruzic, J. J., & Nalla, R. K. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs0505 · Cited by 29
“(88) suggest a higher critical threshold exists for damage accumulation during fatigue under compressive loading (4000 me vs.”
BackgroundA computational insight on damage-based constitutive modelling in femur mechanics
Gaziano, P., Falcinelli, C., & Vairo, G. (2022) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2022.104538 · Cited by 28
Bone Aging by Advanced Glycation End Products: A Multiscale Mechanical Analysis
Ganeko, K., Masaki, C., Shibata, Y., Mukaibo, T., Kondo, Y., Nakamoto, T., Miyazaki, T., & Hosokawa, R. (2015) · Journal of Dental Research · doi:10.1177/0022034515602214 · Cited by 28
“(B) Stress relaxation during the constant strain displacementcontrolled indentation test. time-dependent viscoelasticity (Cristofolini et al. 1996; Pattin et al. 1996; Ji and Gao 2004).”
BackgroundLynch, J. A., & Silva, M. J. (2008) · Bone · doi:10.1016/j.bone.2008.01.004 · Cited by 28
“While there are several reports on the degradation of bone mechanical properties during fatigue (dynamic) loading both in vivo and ex vivo, with reported decreases in modulus [21], strength [7] and stiffness [7,11,29], similar data for in vivo creep (static) loading are lacking.”
BackgroundZhang, X., Liu, X., Yan, Z., Cai, J., Kang, F., Shan, S., Wang, P., Zhai, M., Guo, X., Luo, E., et al. (2018) · Bone · doi:10.1016/j.bone.2018.01.011 · Cited by 28
Mechanical behavior of human cortical bone in cycles of advancing tensile strain for two age groups
Nyman, J. S., Roy, A., Reyes, M., & Wang, X. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31974 · Cited by 30
Does bone design intend to minimize fatigue failures? A case for the affirmative
Frost, H. M. (2000) · Journal of Bone and Mineral Metabolism · doi:10.1007/pl00010642 · Cited by 28
“Burr et al. suggested such a threshold in 1983 [16], and subsequent studies showed it exists [13, 15 ,17,18].”
BackgroundTaylor, M., Verdonschot, N. J. J., Huiskes, R., & Zioupos, P. (1999) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008960630142 · Cited by 28
Mulvihill, B. M., & Prendergast, P. J. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802136150 · Cited by 27
“…critical level of damage, vcrit, at which this resorption process is initiated is taken to be the damage caused by a single loading cycle at 4000m1 (Pattin et al. 1996; numerically this value is calculated by converting the strain value to stress using E ¼ 2.6GPa, (McNamara et al. 2006) and…”
MethodScheidt, A., Wölfer, J., & Nyakatura, J. A. (2019) · Journal of Morphology · doi:10.1002/jmor.21007 · Cited by 27
Failure Processes in Hard and Soft Tissues
Taylor, D. M. (2003) · Elsevier eBooks · doi:10.1016/b0-08-043749-4/09012-1 · Cited by 27
Bruce, O. L., Baggaley, M., Khassetarash, A., Haider, I. T., & Edwards, W. B. (2022) · Bone · doi:10.1016/j.bone.2022.116443 · Cited by 26
Non-destructive characterization of microdamage in cortical bone using low field pulsed NMR
Nicolella, D. P., Ni, Q., & Chan, K. S. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.007 · Cited by 25
“Fatigue loading causes decreases in both bone stiffness, and residual strength (Carter and Hayes, 1977; Hoshaw et al., 1997; Pattin et al., 1996; Schaffler et al., 1989).”
BackgroundA review on experimental and numerical investigations of cortical bone fracture
Kumar, A., & Ghosh, R. (2022) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211070347 · Cited by 26
Cortical and trabecular bone structure of the hominoid capitate
Bird, E. E., Kivell, T. L., & Skinner, M. M. (2021) · Journal of Anatomy · doi:10.1111/joa.13437 · Cited by 26
“Bones loaded in tension have a lower failure point than those loaded in compression (Caler & Carter, 1989; Pattin et al., 1996) and therefore greater BV/TV or Ct.”
Reisinger, A., Frank, M., Thurner, P. J., & Pahr, D. H. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01329-0 · Cited by 25
Wong, K. W., Wu, C. D., Chien, C., Lee, C., Yang, T., & Lin, C. (2020) · Applied Sciences · doi:10.3390/app10124098 · Cited by 24
“Critical damage strain over thresholds of 4000 μm could induce microdamage of bone cells and delay interface bone union or nonunion [18].”
BackgroundLoundagin, L. L., Pohl, A. J., & Edwards, W. B. (2020) · Bone · doi:10.1016/j.bone.2020.115647 · Cited by 24
“Under zero-compression, the fatigue behavior of bone exhibits a two-phase stiffness profile and may not display any indication of stiffness loss until the final 10% of its lifetime [42,43].”
Tendon, ligament, bone, and cartilage: Anatomy, physiology, and adaptations to exercise and training
Patterson‐Kane, J. C., & Firth, E. C. (2013) · Elsevier eBooks · doi:10.1016/b978-0-7216-0075-8.00022-8 · Cited by 25
Fatigue-caused damage in trabecular bone from clinical, morphological and mechanical perspectives
Mirzaali, M. J., Libonati, F., Böhm, C., Rinaudo, L., Cesana, B. M., Ulivieri, F. M., & Vergani, L. M. (2019) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2019.105451 · Cited by 24
A fatigue loading model for investigation of iatrogenic subtrochanteric fractures of the femur
Tsai, A. G., Reich, M. S., Bensusan, J. S., Ashworth, T., Marcus, R. E., & Akkuş, O. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.09.009 · Cited by 23
Brouwers, J. E. M., Ruchelsman, M., van Rietbergen, B., & Bouxsein, M. (2008) · Osteoporosis International · doi:10.1007/s00198-008-0803-z · Cited by 23
“Compressive and tensile fatigue behavior has been well documented for cortical bone from humans as well as animals [26–29].”
BackgroundAli, A., Newman, S., Hooper, P. A., Davies, C. M., & Cobb, J. P. (2017) · Bone and Joint Research · doi:10.1302/2046-3758.68.bjr-2017-0067.r1 · Cited by 22
Metadata
- Authors
- Pattin, C. A., Caler, W. E., & Carter, D. R.
- Affiliations
- University Hospitals of Cleveland (US)
- VA Palo Alto Health Care System (US)
- Corresponding author
- Pattin, C.A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 29
- Issue
- 1
- Pages
- 69-79
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2058028641
- Semantic Scholar
- 92e7f4ca6ca87a130df4f501ddff49b5d7373858
- Cited by
- 442
- References
- 30
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 14 · 2023: 16 · 2022: 20 · 2021: 23 · 2020: 17 · 2019: 14 · 2018: 13 · 2017: 9 · 2016: 12 · 2015: 18 · 2014: 10 · 2013: 18 · 2012: 18
- FWCI
- 21.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ar032377-04)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR 32377)
- Topics
- Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- cortical bone, fatigue damage accumulation, tensile fatigue, compressive fatigue, linear viscoelasticity, fatigue life, bone remodeling, bone modeling
- MeSH terms
- Adolescent, Adult, Algorithms, Bone and Bones, Elasticity, Energy Transfer, Femur, Humans, Male, Middle Aged, Models, Biological, Stress, Mechanical, Tensile Strength, Viscosity, Fractures, Stress, Bone Remodeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.