Cyclic mechanical property degradation during fatigue loading of cortical bone
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Fatigue damage accumulation has been demonstrated in living bone and postulated as a stimulus to the bone modeling and remodeling response. Mechanical property degradation is one manifestation of fatigue damage accumulation. This study examines changes in secant modulus and cyclic energy dissipation behavior during axial load-controlled fatigue loading of cortical bone specimens. The findings suggest that secant modulus degradation and cyclic energy dissipation are greatly increased at loading levels above critical damage strain thresholds of 2500 and 4000 mu epsilon in tensile and compressive fatigue, respectively. Tensile and compressive fatigue loading also caused different forms of modulus degradation at loading levels above these thresholds. Bone behaves as a linear viscoelastic material below these thresholds, even after prior property degradation at higher loading levels. Cyclic energy dissipation was proportional to the 2.1 power of the applied effective strain range for all loadings below 2500 mu epsilon. Above 2500 mu epsilon, tensile fatigue loading caused cyclic energy dissipation proportional to the 5.8 power of the applied effective strain range. Compressive fatigue loading dissipated cyclic energy proportional to the 4.9 power of applied effective strain range over 4000 mu epsilon. Lifetime energy dissipation over all fatigue tests to fracture at a single loading level was well fitted by the same power law in the number of cycles to failure raised to the 0.6 power. Loading levels of 2500 mu epsilon in tension and 4000 mu epsilon in compression are within the ranges observed in living animals, and thus these phenomena may play a role in initiating the remodeling response in live bone tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Fatigue loading results in progressive degradation of mechanical properties such as fracture toughness, modulus, and strength (20, 21).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [20]
Citations
Cites
The Mechanical Adaptations of Bones
Currey, J. D. (1984) · Princeton University Press eBooks · doi:10.1515/9781400853724 · Cited by 896 · cited 1×
“This increased energy dissipation in tensile fatigue may aid in stimulating the preferential remodeling response of bone to tensile loading (Currey, 1984).”
BackgroundStatic vs dynamic loads as an influence on bone remodelling
Lanyon, L. E., & Rubin, C. T. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90003-4 · Cited by 887
Humeral hypertrophy in response to exercise
Jones, H., Priest, J., Hayes, W., Tichenor, C., & Nagel, D. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759020-00012 · Cited by 824
Bone remodeling in response to in vivo fatigue microdamage
Burr, D. B., Martin, R. B., Schaffler, M. B., & Radin, E. L. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90204-0 · Cited by 765 · cited 3×
“Since compact bone is capable of responding to damage accumulation well before specimen fracture (Burr et al., 1985; Martin and Burr, 1982), the prefailure response of compact bone to applied fatigue loading may be of greater clinical relevance than the factors affecting fatigue life.”
BackgroundThe mechanical properties of bone.
Evans, F. G. (1969) · PubMed · Cited by 587
Rubin, C. T., & Lanyon, L. E. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050217 · Cited by 519 · cited 1×
“…correspond well to hypothesized thresholds for remodeling responses in living bone (Burr et al., 1989; Carter, 1987; Cowin, 1986; Frost, 1986; Lanyon, 1987; Lanyon and Rubin, 1984; Rubin and Lanyon 1987) and to the highest strain levels seen in living bone (Bieweiner, 1991; Nunamaker et al., 1990).”
BackgroundMechanical loading history and skeletal biology
Carter, D. R. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90027-3 · Cited by 511 · cited 3×
“In order to model these results, many investigators have advanced the view that mechanical loading is crucial to the maintenance and development of the skeleton (Carter, 1987; Frast.”
BackgroundResultSelf-citationLanyon, L. E. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90026-1 · Cited by 446 · cited 3×
“Peak strains of 1500-2500~ have been commonly observed in a variety of studies (Carter et al., 1981; Lanyon, 1987).”
BackgroundWolff’s Law of Trabecular Architecture at Remodeling Equilibrium
Cowin, S. C. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138584 · Cited by 425 · cited 2×
“…observed in this study correspond well to hypothesized thresholds for remodeling responses in living bone (Burr et al., 1989; Carter, 1987; Cowin, 1986; Frost, 1986; Lanyon, 1987; Lanyon and Rubin, 1984; Rubin and Lanyon 1987) and to the highest strain levels seen in living bone…”
ResultThe effect of prolonged physical training on the properties of long bone: a study of Wolff's Law.
Woo, S. L., Kuei, S. C., Amiel, D., Gomez, M. A., Hayes, W. C., White, F. C., & Akeson, W. H. (1981) · PubMed · Cited by 421
Research works printed but not linked: 2
- Akhter, 1993, Demonstration of fatigue damage effects in rat tibiae, Vol. 18, 197
- Dabastani, 1990, Effect of orientation, strain rate, and temperature on anelasticity of human compact bone, Vol. 2, 104
Cited by
Items 201–300 of 487
Internal Tibial Forces and Moments During Graded Running
Baggaley, M., Derrick, T. R., Vernillo, G., Millet, G. Y., & Edwards, W. B. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4051924 · Cited by 23
Maruyama, N., Shibata, Y., Wurihan, W., Swain, M. V., Kataoka, Y., Takiguchi, Y., Yamada, A., Maki, K., & Miyazaki, T. (2014) · Nanoscale · doi:10.1039/c4nr03180f · Cited by 22
Microstrain fields for cortical bone in uniaxial tension: Optical analysis method
Kim, D., Brunski, J., & Nicolella, D. P. (2005) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/095441105x9291 · Cited by 22
Stout, S. D., Cole, M. E., & Agnew, A. M. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-809738-0.00006-5 · Cited by 26
Probabilistic failure analysis of bone using a finite element model of mineral–collagen composites
Dong, X., Guda, T., Millwater, H. R., & Wang, X. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.022 · Cited by 22
“A number of experimental and theoretical studies have been performed to study the failure behavior of bone at the bulk level (Carter and Caler, 1985; Krajcinovic et al., 1987; Fondrk et al., 1988; Guo et al., 1994; Pattin et al., 1996; Griffin et al., 1997; Levenston and Carter, 1998; Pidaparti et al., 2001).”
Assessing bone's adaptive capacity around dental implants
Greenstein, G., Cavallaro, J., & Tarnow, D. P. (2013) · The Journal of the American Dental Association · doi:10.14219/jada.archive.2013.0129 · Cited by 22
Sex differences in long bone fatigue using a rat model
Moreno, L., Waldman, S. D., & Grynpas, M. D. (2006) · Journal of Orthopaedic Research® · doi:10.1002/jor.20250 · Cited by 21
“Experimental bone fatigue testing, independent of biologic and muscular responses, results in accumulation of microdamage and loss of stiffness.(29) Moreover, creep also occurs during fatigue testing of human cortical bone, resulting in accumulated strain that increases as the tests progress (Fig.”
BackgroundNumerical simulation of bone remodelling around dental implants
Ojeda, J., Martínez‐Reina, J., García‐Aznar, J. M., Domínguez, J., & Doblaré, M. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411911410165 · Cited by 21
The effects of testing methods on the flexural fatigue life of human cortical bone
Griffin, L. V., Gibeling, J. C., Martin, R. B., Gibson, V. A., & Stover, S. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00151-1 · Cited by 21
“…damage, commonly reported in fatigued bone, are a consequence of fatigue loading and are a likely contributor to stress fractures or possibly a mediator for remodeling (Burr et al., 1997; Carter et al., 1977, 1981; Horn, 1993; Pattin et al., 1996, Schaffler et al., 1994a, b; Zioupos et al., 1994).”
BackgroundMethodInfluentialHazelwood, S. J., & Castillo, A. B. (2006) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2006.10.001 · Cited by 21
“While it has been shown that human bone fatigues when subjected to cyclic loading at physiological strain levels [34–37], estimates sug gest that it would take significantly longer for stress frac tures to develop in vivo than what is observed clinically, indicating other factors (e.”
BackgroundKovács, K., Váncsa, S., Agócs, G., Harnos, A., Hegyi, P., Weninger, V., Baross, K., Kovács, B. G., Soós, G., & Kocsis, G. (2023) · JBMR Plus · doi:10.1002/jbm4.10835 · Cited by 22
Experimental evaluation of new concepts in hip arthroplasty
Wik, T. S. (2012) · Acta Orthopaedica · doi:10.3109/17453674.2012.678804 · Cited by 20
Liu, X., Li, W., Cai, J., Yan, Z., Shao, X., Xie, K., Guo, X.-D. E., Luo, E., & Jing, D. (2019) · The FASEB Journal · doi:10.1096/fj.201902011rr · Cited by 20
Calvo‐Gallego, J. L., Manchado-Morales, P., Pivonka, P., & Martínez‐Reina, J. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1060158 · Cited by 20
The effect of stress fracture interventions in a single elite infantry training unit (1983–2015)
Milgrom, C., & Finestone, A. S. (2017) · Bone · doi:10.1016/j.bone.2017.06.026 · Cited by 19
Fatigue evaluation of long cortical bone using ultrasonic guided waves
Bai, L., Xu, K., Li, D., Ta, D., Le, L. H., & Wang, W. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.06.015 · Cited by 19
Simpson, D. J. W., Little, J. P., Gray, H. A., Murray, D. W., & Gill, H. S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.12.010 · Cited by 19
“ative bone remodelling under compressive loading (Pattin et al., 1996).”
BackgroundInfluentialMassoumi, F., Taheri, M., Mohammadi, A., & Amelirad, O. (2018) · PubMed Central · Cited by 19
Lad, S. E., McGraw, W. S., & Daegling, D. J. (2019) · Bone · doi:10.1016/j.bone.2019.07.027 · Cited by 19
Hambli, R., & Hattab, N. (2012) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/8415_2012_146 · Cited by 19
Topoliński, T., Cichański, A., Mazurkiewicz, A., & Nowicki, K. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.05.032 · Cited by 19
Systematic error in mechanical measures of damage during four-point bending fatigue of cortical bone
Landrigan, M. D., & Roeder, R. K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.03.016 · Cited by 20
“The initial modulus or stiffness of a specimen is often measured prior to fatigue testing in order to normalize tissue heterogeneity to a prescribed maximum strain (Boyce et al., 1998; Caler and Carter, 1989; Cotton et al., 2005; Diab et al., 2006; Diab and Vashishth, 2005; Gibson et al., 1995; Pattin et al., 1996; Pi…”
InfluentialThe characterization of human cortical bone microdamage by nuclear magnetic resonance
Ni, Q., & Nicolella, D. P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/3/006 · Cited by 20
Maquer, G., Bürki, A., Nuss, K. M. R., Zysset, P. K., & Tannast, M. (2016) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-016-5024-8 · Cited by 18
“This choice of loading is legitimate as quasistatic and passive fatigue properties of bone scale well in terms of strains [17, 18].”
BackgroundFatigue behavior of subchondral bone under simulated physiological loads of equine athletic training
Shaktivesh, S., Malekipour, F., Whitton, R. C., Hitchens, P. L., & Lee, P. V. S. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103920 · Cited by 18
Lower-limb joint kinetics in jump rope skills performed by competitive athletes
Bruce, O. L., Ramsay, M., Kennedy, G., & Edwards, W. B. (2020) · Sports Biomechanics · doi:10.1080/14763141.2020.1801823 · Cited by 18
Understanding the etiology of the posteromedial tibial stress fracture
Milgrom, C., Burr, D. B., Finestone, A. S., & Voloshin, A. (2015) · Bone · doi:10.1016/j.bone.2015.04.033 · Cited by 18
“The level of the loading and the number of loading cycles necessary to cause human cortical bone fatigue failure and stress fracture have been the subject of ex vivo studies [3–6].”
BackgroundInfluentialMulti-Scale Modeling of Human Cortical Bone: Aging and Failure Studies
Budyn, É., & Hoc, T. (2006) · MRS Proceedings · doi:10.1557/proc-975-0975-dd02-06 · Cited by 18
Yan, C., Bice, R. J., Frame, J. W., Warden, S. J., & Kersh, M. E. (2021) · Bone · doi:10.1016/j.bone.2022.116392 · Cited by 18
Changes in bone fatigue resistance due to collagen degradation
Wynnyckyj, C., Willett, T. L., Omelon, S. J., Wang, J., Wang, Z., & Grynpas, M. D. (2010) · Journal of Orthopaedic Research® · doi:10.1002/jor.21228 · Cited by 19
Chen, J. C., Beaupré, G. S., & Carter, D. R. P. (2009) · Bone · doi:10.1016/j.bone.2009.09.030 · Cited by 18
“4B indicates the onset of major fatigue microdamage, which is presumed to occur at 4000 microstrain/day (2504=4000–1496 microstrain/day) [15].”
BackgroundInfluentialSelf-citationFrost, H. M. (1997) · Journal of Bone and Mineral Metabolism · doi:10.1007/bf02439449 · Cited by 18
“While the text spoke of longitudinal strain magnitudes as a major control of a bone's structural adaptations to its mechanical usage (SATMU), shear, and strain gradients, frequencies, total numbers, and rates, may help in that control, and other factors may help, too [16,21,22,29,41,47,72,79].”
BackgroundMacione, J., Kavukcuoglu, N. B., Nesbitt, R. S., Mann, A. B., Güzelsu, N., & Kotha, S. P. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.03.010 · Cited by 18
On the strength-safety factor (SSF) for load-bearing skeletal organs.
Hm, F. (2003) · PubMed · Cited by 17
A damage assessment model for cadaveric cortical bone subjected to fatigue cycles
Varvani-Farahani, A., & Najmi, H. (2010) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2009.08.002 · Cited by 16
Cho, B. W., Kang, K., Kwon, H. M., Lee, W.-S., Yang, I. H., Nam, J. H., Koh, Y., & Park, K. K. (2022) · Bone and Joint Research · doi:10.1302/2046-3758.115.bjr-2021-0537.r1 · Cited by 16
Bruce, O. L., & Edwards, W. B. (2023) · Bone · doi:10.1016/j.bone.2023.116803 · Cited by 16
Hoffseth, K., Randall, C. J., Hansma, P. K., & Yang, H. T. Y. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.11.020 · Cited by 18
Fatigue data analysis of canine femurs under four-point bending.
Pidaparti, R. M. V., Akyüz, U., Naick, P., & Burr, D. B. (2000) · PubMed · Cited by 17
Macrodamage Accumulation Model for a Human Femur
Hamandi, F., & Goswami, T. (2017) · Applied Bionics and Biomechanics · doi:10.1155/2017/4539178 · Cited by 16
“The fi rst model [25] shows cortical bone behavior, and the study was done on a small sample of the femoral bone.”
MethodOn numerical modelling of growth, differentiation and damage in structural living tissues
Doblaré, M., & García‐Aznar, J. M. (2006) · Archives of Computational Methods in Engineering · doi:10.1007/bf02905856 · Cited by 16
Chapurlat, R. D. (2009) · Osteoporosis International · doi:10.1007/s00198-009-0859-4 · Cited by 16
“In addition, bone elastic modulus' decline after fatigue loading [15, 16] parallels microcrack accumulation [14, 17].”
BackgroundFrost, H. M. (1997) · The Anatomical Record · doi:10.1002/(sici)1097-0185(199707)248:3<475::aid-ar21>3.0.co;2-l · Cited by 16
Constitutive relationship of tissue behavior with damage accumulation of human cortical bone
Luo, Q., Leng, H., Acuna, R. L., Dong, X. N., Rong, Q., & Wang, X. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.04.026 · Cited by 15
Barkaoui, A., Kahla, R. B., Merzouki, T., & Hambli, R. (2019) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519419500416 · Cited by 15
Skedros, J. G., Sybrowsky, C. L., Anderson, W. E., & Chow, F. S. (2011) · Journal of Anatomy · doi:10.1111/j.1469-7580.2011.01428.x · Cited by 15
“injury to osteocyte dendrites) that can evoke the remodeling response by causing osteocytic apoptosis (Pattin et al. 1996; Reilly & Currey, 1999; George & Vashishth, 2005; Hazenberg et al. 2006; Cardoso et al. 2009).”
BackgroundExperimental and finite element analysis of tibial stress fractures using a rabbit model
Franklyn, M., & FIELD, B. (2013) · World Journal of Orthopedics · doi:10.5312/wjo.v4.i4.267 · Cited by 15
Relative Energy Deficiency in Sport (RED-S) and Bone Stress Injuries
Kim, D. R., & Weber, K. M. (2023) · Operative Techniques in Sports Medicine · doi:10.1016/j.otsm.2023.151025 · Cited by 14
Bone stress injuries of the leg in athletes
Gaeta, M., Mileto, A., Ascenti, G., Bernava, G., Murabito, A., & Minutoli, F. (2013) · La radiologia medica · doi:10.1007/s11547-013-0951-x · Cited by 14
Comparison of Posterior Fixation Strategies for Thoracolumbar Burst Fracture: A Finite Element Study
Wong, C., Hu, H., Tsai, C.-H., Li, J.-L., Hsieh, C.-C., & Huang, K. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4050537 · Cited by 14
Milgrom, C., Finestone, A. S., & Voloshin, A. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.105146 · Cited by 14
Increased strain in the femoral neck following insertion of a resurfacing femoral prosthesis
Wik, T. S., Østbyhaug, P. O., Klaksvik, J., & Aamodt, A. (2010) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.92b3.22592 · Cited by 14
Bone Response to Mechanical Loads
Ramaswamy, G., Bidez, M. W., & Misch, C. E. (2014) · Elsevier eBooks · doi:10.1016/b978-0-323-07845-0.00006-3 · Cited by 15
Influence of Activity Level on Patellar Ultrasound Transmission Velocity in Children
Lappe, J. M., Recker, R. R., & Weidenbusch, D. (1998) · Osteoporosis International · doi:10.1007/s001980050046 · Cited by 14
Keast, M., Bonacci, J., & Fox, A. S. (2022) · Sports Medicine · doi:10.1007/s40279-022-01703-1 · Cited by 13
“In healthy individuals, there is a balance between the reabsorption and formation of bone, and strain induced microdamage is removed successfully [10].”
BackgroundYu, W., Park, H., Kyung, H., & Kwon, O.-W. (2012) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2012.08.016 · Cited by 13
Gargac, J. A., Turnbull, T. L., Roeder, R. K., & Niebur, G. L. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.11.009 · Cited by 13
Fatigue Energy Dissipation in Trabecular Bone Samples with Stepwise-Increasing Amplitude Loading*
Topoliński, T., Cichański, A., Mazurkiewicz, A., & Nowicki, K. (2011) · Materials Testing · doi:10.3139/120.110235 · Cited by 13
Fatigue reliability analysis for medial tibial stress syndrome
Ghasemi, S. H., Kalantari, H., Abdollahikho, S. S., & Nowak, A. S. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.01.076 · Cited by 13
The Role of Bone Remodeling in Preventing or Promoting Stress Fractures
Martin, R. B. (2000) · CRC Press eBooks · doi:10.1201/9781420042191-16 · Cited by 13
Nadda, R., Repaka, R., & Sahani, A. K. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2095204 · Cited by 12
“In case of a bone as shown in Equation (6), the maximum primary strain of 0.4 percent is employed as a failure condition (Pattin et al. 1996; Bayraktar et al. 2004).”
MethodInfluentialPivonka, P., Calvo‐Gallego, J. L., Schmidt, S., & Martínez‐Reina, J. (2024) · Bone · doi:10.1016/j.bone.2024.117140 · Cited by 12
Initial anisotropy in demineralized bovine cortical bone in compressive cyclic loading–unloading
Novitskaya, E. E., Lee, S., Lubarda, V. A., & McKittrick, J. M. (2012) · Materials Science and Engineering C · doi:10.1016/j.msec.2012.11.006 · Cited by 12
Wong, C., Hu, H., Kao, L.-H., Liu, C.-J., Chen, K.-C., & Huang, K. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04958-3 · Cited by 12
“The strain energy stored in the material during repetitive motion is related to fatigue of the material and this may make the IVD susceptible to chronic disc degeneration and progression of the pre-existing disc degeneration to higher-grade degeneration [58].”
BackgroundHudieb, M., Wakabayashi, N., Suzuki, T., & Kasugai, S. (2010) · PubMed · Cited by 12
Bone collagen tensile properties of the aging human proximal femur
Bracher, S., Voumard, B., Simon, M., Kochetkova, T., Pretterklieber, M. L., & Zysset, P. K. (2024) · Bone Reports · doi:10.1016/j.bonr.2024.101773 · Cited by 11
“…of the demineralized samples are well comparable to the literature (Carter et al., 1981; Catanese III et al., 1999; Jepsen et al., 1999; Kotha and Guzelsu, 2003; Mirzaali et al., 2016; Pattin et al., 1996; Reilly et al., 1974; Reilly and Burstein, 1975; Wang et al., 2002; Zioupos and Currey, 1998).”
Gustafsson, A., Galteri, G., Barakat, A., Engqvist, J., Grassi, L., Cristofolini, L., Dejea, H., & Isaksson, H. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106721 · Cited by 11
Hm, F. (2003) · PubMed · Cited by 11
Modelling fracture processes in bones
Abdelwahab, A. A., Li, S., & Silberschmidt, V. V. (2014) · Elsevier eBooks · doi:10.1533/9780857096739.2.268 · Cited by 11
3D finite element simulation of human proximal femoral fracture under quasi-static load
Hambli, R. (2013) · Advances in Biomechanics and Applications · doi:10.12989/aba.2013.1.1.001 · Cited by 11
“At continuum level, the local critical damage value in tension is generally equal to 1 ( 0.1TcD ) (Zioupos et al. 1996, Pattin et al. 1996).”
BackgroundBerli, M. E., Franco, F., Paolo, J. D., Zioupos, P., & Borau, C. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105898 · Cited by 10
Sun, B., Kitchen, G. B., He, D., Malu, D. K., Ding, J., Huang, Y., Eisape, A. A., Omar, M. M., Hu, Y., & Kang, S. H. (2025) · Science Advances · doi:10.1126/sciadv.adt3979 · Cited by 10
Malekipour, F., Whitton, R. C., & Lee, P. V. S. (2020) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2020.100036 · Cited by 10
Bennett, M. B., & Forwood, M. R. (2010) · Australian Zoologist · doi:10.7882/az.2010.022 · Cited by 10
Guillén-Girón, T., Ohrndorf, A., Tozzi, G., Tong, J., & Christ, H. (2011) · Advanced Engineering Materials · doi:10.1002/adem.201180060 · Cited by 10
The Role of Strain and Strain Rates in Stress Fractures
Milgrom, C. (2000) · Exercise physiology/CRC series in exercise physiology · doi:10.1201/9781420042191.ch8 · Cited by 10
Ruiz-Lozano, R., Calvo‐Gallego, J. L., Pivonka, P., & Martínez‐Reina, J. (2025) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-024-01900-z · Cited by 9
“…(2005) for ̇ d under tensile stresses, which once integrated yields: where N is the number of cycles applied, ε max is the maximum principal strain 1 expressed in με and C 1 , C 2 , γ f and δ f were fitted by García-Aznar et al. (2005) to reproduce the fatigue experiments of Pattin et al. (1996).”
A continuum damage model of fatigue and failure in whole bone
Dimnik, J. M., Haider, I. T., & Edwards, W. B. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.105907 · Cited by 9
Damage accumulation of bovine bone under variable amplitude loads
Abbey, C., Cler, M. L., Skurla, C. P., & Kuehl, J. (2016) · Bone Reports · doi:10.1016/j.bonr.2016.11.001 · Cited by 9
Wong, C., Hu, H., Huang, Y.-H., & Huang, K. (2022) · Bioengineering · doi:10.3390/bioengineering9100491 · Cited by 9
“On the other hand, cyclic strain energy during repetitive motion is related to material fatigue, so the strain energy density in pedicle screws may be an indicator of the constructs’ susceptibility to implant failure due to long-term wear [46].”
BackgroundTobe, T., Shibata, Y., Mochizuki, A., Shimomura, N., Zhou, J. M., Wurihan, Tanaka, R., Ikeda, S., Zhang, Z., Li, Q., et al. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.10.015 · Cited by 9
Zdero, R., Brzozowski, P., & Schemitsch, E. H. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00178 · Cited by 8
A Preliminary Biomechanical Study of Cyclic Preconditioning Effects on Canine Cadaveric Whole Femurs
Zdero, R., Gallimore, C. H., McConnell, A. J., Patel, H., Nisenbaum, R. A., Morshed, G., Koo, H., McKee, M. D., Schemitsch, E. H., & Bougherara, H. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4007249 · Cited by 8
Bird, E. E., Kivell, T. L., & Skinner, M. M. (2021) · American Journal of Biological Anthropology · doi:10.1002/ajpa.24449 · Cited by 9
Pauzenberger, L., Dwyer, C., Obopilwe, E., Nowak, M. D., Cote, M. P., Romeo, A. A., Mazzocca, A. D., & Dyrna, F. G. E. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2968-3 · Cited by 8
Ray, T. J., McGraw, W. S., Sun, Z., Jeon, M., Johnson, T., Cheffins, K., Daegling, D. J., & Kim, D. (2015) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2015.09.011 · Cited by 8
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Ribose pre-treatment can protect the fatigue life of γ-irradiation sterilized bone
Attia, T., Grynpas, M. D., & Willett, T. L. (2019) · Cell and Tissue Banking · doi:10.1007/s10561-019-09767-6 · Cited by 7
Chen, X., Myers, C. A., Clary, C. W., DeWall, R. J., Fritz, B., Blauth, M., & Rullkoetter, P. J. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110363 · Cited by 7
Effects of Fatigue Damage on the Microscopic Modulus of Cortical Bone Using Nanoindentation
Meng, X., Qu, C., Fu, D., & Fu, D. (2021) · Materials · doi:10.3390/ma14123252 · Cited by 7
“as an increase in strain with cycles [6,11,53].”
BackgroundInfluentialThe characterization of bovine compact bone fatigue damage using terahertz spectroscopy
Meng, X., Qin, Q., Qu, C., Kang, K., Wang, Z., Qiu, W., Qu, C., & Fu, D. (2022) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2022.06.001 · Cited by 7
“, by lowering stiffness and increasing plastic deformation [49,50].”
BackgroundReisinger, A., Frank, M., Thurner, P. J., & Pahr, D. H. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106259 · Cited by 7
Experimental and numerical analysis of Izod impact test of cortical bone tissue
Abdelwahab, A. A., & Silberschmidt, V. V. (2012) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2012-01585-3 · Cited by 7
Han, P., Jang, Y., Yoo, O. S., Kim, J. S., Kim, H. S., & Lim, D. (2013) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2013.34.1.14 · Cited by 7
“또한 예측된 변형률은 Pattin 등[29]에 의해 보고된 골재형성(Bone Remodeling)에 직접 적인 영향을 줄 수 있는 골의 임계 손상 변형률 이하임을”
Liu, X., Tang, C., Zhang, X., Cai, J., Yan, Z., Xie, K., Yang, Z., Wang, J., Guo, X., Luo, E., et al. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24391 · Cited by 7
Mechanical testing and modelling of a bone-implant construct
Grant, C. A. (2012) · Cited by 7
Rieger, R. (2011) · theses.fr (ABES) · doi:10.70675/ad781ab0z43b9z43a4zaf69z46aed5ebab0c · Cited by 8
Barkaoui, A. (2012) · theses.fr (ABES) · doi:10.70675/03625c86z58daz485dz9b5dzf1da050608ab · Cited by 7
SINCLAIR, J. K., & Taylor, P. J. (2023) · Computation · doi:10.3390/computation11120248 · Cited by 6
Vargas‐Moreno, V. F., Ribeiro, M. C. D. O., Gomes, R. S., Bergamo, E. T. P., Bonfante, E. A., Cury, A. A. D. B., & Marcello‐Machado, R. M. (2025) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35560 · Cited by 6
Metadata
- Authors
- Pattin, C. A., Caler, W. E., & Carter, D. R.
- Affiliations
- University Hospitals of Cleveland (US)
- VA Palo Alto Health Care System (US)
- Corresponding author
- Pattin, C.A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 29
- Issue
- 1
- Pages
- 69-79
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2058028641
- Semantic Scholar
- 92e7f4ca6ca87a130df4f501ddff49b5d7373858
- Cited by
- 442
- References
- 30
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 14 · 2023: 16 · 2022: 20 · 2021: 23 · 2020: 17 · 2019: 14 · 2018: 13 · 2017: 9 · 2016: 12 · 2015: 18 · 2014: 10 · 2013: 18 · 2012: 18
- FWCI
- 21.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ar032377-04)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR 32377)
- Topics
- Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- cortical bone, fatigue damage accumulation, tensile fatigue, compressive fatigue, linear viscoelasticity, fatigue life, bone remodeling, bone modeling
- MeSH terms
- Adolescent, Adult, Algorithms, Bone and Bones, Elasticity, Energy Transfer, Femur, Humans, Male, Middle Aged, Models, Biological, Stress, Mechanical, Tensile Strength, Viscosity, Fractures, Stress, Bone Remodeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.