The dependence of shear failure properties of trabecular bone on apparent density and trabecular orientation
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A General Theory of Strength for Anisotropic Materials
Tsai, S. W., & Wu, E. M. (1971) · Journal of Composite Materials · doi:10.1177/002199837100500106 · Cited by 3,393 · cited 2×
“, 1994~; unpublished data), we predicted yield stresses for off-axis compressive loads acting from 0” to 90” relative to the primary orientation using a maximum stress (Jones, 1975) and a Tsai-Wu failure criterion (Tsai and Wu, 1971).”
BackgroundMethodMechanics of Composite Materials
Jones, R. M., & Bert, C. W. (1975) · Journal of Applied Mechanics · doi:10.1115/1.3423688 · Cited by 3,205
Theory of flow and fracture of solids
Nádai, Á. (1950) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,997
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 1×
“Although values for shear failure stains have not been reported, previous investigators have concluded that compressive failure strains are isotropic (Turner, 1989) or slightly anisotropic (Mosekilde et al., 1987), which is in general consistent with our results for shear failure strains.”
ResultKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationFracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300
Self-citationTensile and compressive properties of cancellous bone
Røhl, L., Larsen, E., Linde, F., Odgaard, A., & Jørgensen, J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90006-9 · Cited by 279
Elastic properties of cancellous bone: Measurement by an ultrasonic technique
Ashman, R. B., Corin, J. D., & Turner, C. H. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90327-7 · Cited by 227 · cited 1×
“Our shear modulus values also compare favorably with those measured by ultrasound for the bovine femur (Ashman et al., 1987).”
BackgroundCheal, E. J., Spector, M., & Hayes, W. C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100314 · Cited by 213 · cited 1×
“If the high shear stresses which exist near prostheses (Cheal et al., 1992) exceed the shear strength of trabecular bone, prosthesis loosening may occur.”
Background
Cited by
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653
Self-citationBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Metallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“Several authors [37,125] suggest that strain-based failure theories are better than stress-based ones, but others indicate the opposite [39].”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431
Self-citationFracture in human cortical bone: local fracture criteria and toughening mechanisms
Nalla, R. K., Stölken, J. S., Kinney, J. H., & Ritchie, R. O. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.010 · Cited by 260
“In the present work, firstly in terms of intrinsic damage, we have provided sound evidence that the onset of fracture in human cortical bone is consistent with a strain-based criterion, which has been so widely used in theoretical models of the mechanical behavior of bone (Keaveny et al., 1994; Ford and Keaveny, 1996;…”
BackgroundKeyak, J. H., & Rossi, S. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00152-9 · Cited by 250
Dependence of Intertrabecular Permeability on Flow Direction and Anatomic Site
Nauman, E. A., Fong, K. E., & Keaveny, T. M. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.195 · Cited by 249
Self-citationNazarian, A., von Stechow, D., Zurakowski, D., Müller, R., & Snyder, B. D. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9174-x · Cited by 244
“Since buckling and bending are the predominant modes of trabecular deformation and failure [49, 50], these changes in trabecular structure influence the mechanical behavior of cancellous bone in disproportion to the corresponding change in mineral mass [40, 51, 52].”
BackgroundSeebeck, J., Goldhahn, J., Städele, H., Messmer, P., Morlock, M. M., & Schneider, E. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2004.04.001 · Cited by 166
Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77
Self-citationAnisotropy of the fatigue behaviour of cancellous bone
Dendorfer, S., Maier, H. J., Taylor, D., & Hammer, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.037 · Cited by 76
Heterogeneity of yield strain in low-density versus high-density human trabecular bone
Bevill, G., Farhamand, F., & Keaveny, T. M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.023 · Cited by 57
Self-citation
Metadata
- Authors
- Ford, C. M., & Keaveny, T. M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1996-10
- Volume
- 29
- Issue
- 10
- Pages
- 1309-1317
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2111585629
- Cited by
- 158
- References
- 19
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.