Capillary electrophoresis-mass spectrometry
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
As an on-line separation method, capillary electrophoresis (CE)-mass spectrometry (MS) distinguishes analytes by both their differences in electrophoretic mobilities and structural information. CE-MS combines the advantages of CE and MS so that information on both high separation efficiency and molecular masses and/or fragmentation can be obtained in one analysis. During the past few years CE-MS has undergone significant development both in instrumentation and application. Several ionization methods have been used for CE-MS. These include electrospray ionization, ion spray or pneumatically assisted electrospray ionization, and continuous-flow fast atom bombardment. The direct coupling of CE to desorption MS has not yet been reported, although publications have appeared on the off-line coupling of CE with matrix-assisted laser desorption ionization and 252Cf plasma desorption MS using fraction collection. Numerous new applications of CE-MS have been published in the areas of biological sciences, pharmaceutical and drug metabolism, and environmental analysis. The majority of applications of CE-MS have been in the field of biological and biochemical studies. Several limitations associated with CE-MS have precluded the technique being widely accepted for routine analysis. The major limitation is its relatively poor concentration sensitivity. The concentration detection limits of currently available CE-MS instrumentation are too high for most real-world applications. Other drawbacks with CE-MS include the fluctuation in analyte migration time and limitations in electrolyte selections. Approaches to improve the concentration sensitivity of CE-MS include on-line preconcentration either by capillary isotachophoresis or chromatographic methods. Another solution to increasing the sensitivity of CE-MS is the development of alternative types of mass spectrometers which offer the potential for greater sensitivity, such as ion trap, Fourier transform ion cyclotron resonance, and time-of-flight (TOF) mass spectrometers. Coated capillaries are useful in improving separation efficiencies of biomolecules by minimizing their adsorption onto the CE capillary walls. At present, CE-MS is still not generally considered for routine analysis mainly due to its limited concentration sensitivity. As a complementary separation method to LC-MS with extremely high efficiency, CE-MS has the potential for wide acceptance in the future. The popularity of CE-MS will continue to grow, as more sensitive MS instrumentation and CE-MS interface are developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zone electrophoresis in open-tubular glass capillaries
Jorgenson, J. W., & Lukacs, K. D. (1981) · Analytical Chemistry · doi:10.1021/ac00231a037 · Cited by 2,229
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry
Barber, M., Bordoli, R. S., Sedgwick, R. D., & Tyler, A. N. (1981) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39810000325 · Cited by 1,106
Instability of Electrified Liquid Surfaces
Zeleny, J. (1917) · Physical Review · doi:10.1103/physrev.10.1 · Cited by 944
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry
Smith, R. D., Barinaga, C. J., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00169a022 · Cited by 535
Electrospray-ion spray: a comparison of mechanisms and performance
Ikonomou, M. G., Blades, A. T., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00018a017 · Cited by 322
High-resolution electrospray mass spectra of large molecules
Henry, K. D., Quinn, J. P., & McLafferty, F. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00014a043 · Cited by 309
Techniques in Protein Chemistry V
Walker, J. (1993) · Cited by 268
Lee, E. D., Mück, W., Henion, J. D., & Covey, T. R. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)90575-2 · Cited by 209
Self-citationLiquid junction coupling for capillary zone electrophoresis/ion spray mass spectrometry
Lee, E. D., Mück, W., Henion, J. D., & Covey, T. R. (1989) · Biological Mass Spectrometry · doi:10.1002/bms.1200180932 · Cited by 180
Self-citationSmall volume and low flow‐rate electrospray lonization mass spectrometry of aqueous samples
Gale, D. C., & Smith, R. D. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071111 · Cited by 176
Wahl, J. H., Gale, D. C., & Smith, R. D. (1994) · Journal of Chromatography A · doi:10.1016/0021-9673(94)85026-7 · Cited by 176
Thompson, T. J., Foret, F., Vouros, P., & Karger, B. L. (1993) · Analytical Chemistry · doi:10.1021/ac00055a012 · Cited by 167
Principles and applications of matrix-assisted UV-laser desorption/ionization mass spectrometry
Karas, M., Bahr, U., Ingendoh, A., Nordhoff, E., Stahl, B., Strupat, K., & Hillenkamp, F. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)83645-4 · Cited by 164
Desolvation of ions and molecules in thermospray mass spectrometry
Schmelzeisen-Redeker, G., Bütfering, L., & Röllgen, F. W. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85004-9 · Cited by 163
Pleasance, S., Thibault, P., & Kelly, J. F. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80250-x · Cited by 144
Method for the electrospray ionization of highly conductive aqueous solutions
Chowdhury, S. K., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00015a030 · Cited by 137
Determination of bioactive peptides using capillary zone electrophoresis/mass spectrometry
Moseley, M. A., Deterding, L. J., Tomer, K. B., & Jorgenson, J. W. (1991) · Analytical Chemistry · doi:10.1021/ac00002a005 · Cited by 134
Capillary Electrophoresis/Mass Spectrometry
Smith, R. D., Wahl, J. H., Goodlett, D. R., & Hofstadler, S. A. (1993) · Analytical Chemistry · doi:10.1021/ac00061a717 · Cited by 133
Moseley, M. A., Jorgenson, J. W., Shabanowitz, J., Hunt, D. F., & Tomer, K. B. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87056-5 · Cited by 130
Analysis of paralytic shellfish poisons by capillary electrophoresis
Thibault, P., Pleasance, S., & Laycock, M. V. (1991) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)88783-5 · Cited by 118
Wahl, J. H., Goodlett, D. R., Udseth, H. R., & Smith, R. D. (1992) · Analytical Chemistry · doi:10.1021/ac00048a019 · Cited by 116
Capillary electrophoresis—mass spectrometry
Niessen, W. M. A., Tjaden, U. R., & van der Greef, J. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)80051-9 · Cited by 115
Capillary zone electrophoresis/tandem mass spectrometry for the determination of sulfonated azo dyes
Lee, E. D., Mück, W., Henion, J. D., & Covey, T. R. (1989) · Journal of Mass Spectrometry · doi:10.1002/bms.1200180408 · Cited by 105
Self-citationCaprioli, R. M., Moore, W. T., Martin, M. K., DaGue, B. B., Wilson, K., & Moring, S. (1989) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)84292-8 · Cited by 104
High-flow ion spray liquid chromatography/mass spectrometry
Gérard Hopfgartner, D., Wachs, T., Bean, K. A., & Henion, J. D. (1993) · Analytical Chemistry · doi:10.1021/ac00052a021 · Cited by 98
Self-citationInstrumentation for high-performance capillary electrophoresis—mass spectrometry
Smith, R. D., Udseth, H. R., Barinaga, C. J., & Edmonds, C. G. (1991) · Journal of Chromatography A · doi:10.1016/0021-9673(91)80070-w · Cited by 96
Johansson, I. M., Huang, E. C., Henion, J. D., & Zweigenbaum, J. A. (1991) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)88459-4 · Cited by 95
Self-citationWahl, J. H., Goodlett, D. R., Udseth, H. R., & Smith, R. D. (1993) · ELECTROPHORESIS · doi:10.1002/elps.1150140170 · Cited by 86
Moseley, M. A., Deterding, L. J., Tomer, K. B., & Jorgenson, J. W. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290030310 · Cited by 79
On-line capillary electrophoresis with Fourier transform ion cyclotron resonance mass spectrometry
Hofstadler, S. A., Wahl, J. H., Bruce, J. E., & Smith, R. D. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00068a070 · Cited by 72
Varghese, J., & Cole, R. B. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)83255-q · Cited by 71
Kostiainen, R. K., Bruins, A. P., & Häkkinen, V. M. A. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)80318-3 · Cited by 67
Keough, T. W., Takigiku, R., Lacey, M. P., & Purdon, M. P. (1992) · Analytical Chemistry · doi:10.1021/ac00038a016 · Cited by 66
Morita, I., & Sawada, J. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)80154-z · Cited by 63
Castoro, J. A., Chiu, R. W., Monnig, C. A., & Wilkins, C. L. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00045a044 · Cited by 61
Reduced elution speed detection for capillary electrophoresis/mass spectrometry
Goodlett, D. R., Wahl, J. H., Udseth, H. R., & Smith, R. D. (1993) · Journal of Microcolumn Separations · doi:10.1002/mcs.1220050109 · Cited by 58
Lamoree, M. H., Reinhoud, N. J., Tjaden, U. R., et al. (1994) · Journal of Mass Spectrometry · doi:10.1002/bms.1200230607 · Cited by 58
Mück, W. M., & Henion, J. D. (1989) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)82608-0 · Cited by 58
Self-citationMoseley, M. A., Deterding, L. J., Tomer, K. B., & Jorgenson, J. W. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)90214-6 · Cited by 48
Reinhoud, N. J., Tinke, A. P., Tjaden, U. R., et al. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)87206-n · Cited by 46
Parker, C. E., Perkins, J. R., Tomer, K. B., et al. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)85034-h · Cited by 44
Static and scanning array detection in capillary electrophoresis-mass spectrometry
Reinhoud, N. J., Schroder, E., Tjaden, U. R., et al. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)90212-2 · Cited by 33
Tsuji, K., Baczynskyj, L., & Bronson, G. E. (1992) · Analytical Chemistry · doi:10.1021/ac00041a022 · Cited by 27
Capillary‐zone electrophoresis with fraction collection for desorption mass spectrometry
Takigiku, R., Keough, T. W., Lacey, M. P., & Schneider, R. E. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040108 · Cited by 26
Weinmann, W., Parker, C. E., Baumeister, K., Maier, C. S., Tomer, K. B., & Przybylski, M. (1994) · Electrophoresis · doi:10.1002/elps.1150150139 · Cited by 23
Kostiainen, R. K., Lasonder, E., Bloemhoff, W., van Veelen, P. A., Welling, G. W., & Bruins, A. P. (1994) · Journal of Mass Spectrometry · doi:10.1002/bms.1200230608 · Cited by 9
Edmonds, C. G., Loo, J. A., Loo, R. R. O., et al. (1991) · Biochemical Society Transactions · doi:10.1042/bst0190943 · Cited by 9
Cited by
Luo, B., Groenke, K., Takors, R., Wandrey, C., & Oldiges, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.02.034 · Cited by 460
(2000) · CRC Press eBooks · doi:10.1201/9780203909539 · Cited by 376
Generating Electrospray from Microchip Devices Using Electroosmotic Pumping
Ramsey, R. S., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac9610671 · Cited by 350
Handbook of Affinity Chromatography
(2005) · CRC Press eBooks · doi:10.1201/9780824751982 · Cited by 310
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Metadata
- Authors
- Cai, J., & Henion, J.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 1995-06
- Volume
- 703
- Issue
- 1-2
- Pages
- 667-692
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W1974234926
- Cited by
- 305
- References
- 51
- FWCI
- 17.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.