The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
A review of the immobilization of enzymes in electropolymerized films
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Polyphenol permselective membranes are able to electropolymerize within an enzyme layer in a controllable manner, yielding a film with a thickness that is self-limiting (10–100 nm).”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [59]
Citations
Cites
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G. B., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,667
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
Foulds, N. C., & Lowe, C. R. (1988) · Analytical Chemistry · doi:10.1021/ac00173a008 · Cited by 613
Protein-modified electrodes. The glucose oxidase/polypyrrole system
Umaña, M., & Waller, J. (1986) · Analytical Chemistry · doi:10.1021/ac00127a018 · Cited by 588
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570
Foulds, N. C., & Lowe, C. R. (1986) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19868201259 · Cited by 532
Sasso, S. V., Pierce, R. J., Walla, R., & Yacynych, A. M. (1990) · Analytical Chemistry · doi:10.1021/ac00210a004 · Cited by 343
Electrochemical immobilisation of enzymes
Bartlett, P. N., & Whitaker, R. G. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85082-9 · Cited by 329
Mell, L. D., & Maloy, J. T. (1975) · Analytical Chemistry · doi:10.1021/ac60352a006 · Cited by 292
Rotating ring-disk enzyme electrode for surface catalysis studies
Shu, F. R., & Wilson, G. S. (1976) · Analytical Chemistry · doi:10.1021/ac50006a014 · Cited by 254
Electrochemical immobilisation of enzymes
Bartlett, P. N., & Whitaker, R. G. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)85081-7 · Cited by 248
Research works printed but not linked: 12
- Narasimham, 1986, Anal. Chem., 58, 2989
- Diaz, 1986, 1, 81
- Chandler, 1985, 10, 117
- Bentley, 1973, 7, 567
- Dicks, 1989, Ann. Biol. Clin., 47, 607
- Engasser, 1976, 1, 127
- Bartlett, 1991, Progr. React. Kinet., 16, 55
- J.M. Cooper and D. Bloor, Electroanalysis in press.
- Scott, 1983, J. Phys. B, 28, 2140
- Ohnuki, 1984, J. Electroanal. Chem., 158, 55
- Oshaka, 1984, Anal. Chem., 59, 1758
- Sasso, 1990, Anal. Chem., 62, 1111, 10.1021/ac00210a004 · DOI
Cited by
Sorted by citations
Items 201–300 of 469
Graphene patterned polyaniline-based biosensor for glucose detection
Nguyen, H. B., Nguyen, V. C., Tú, N. V., Ngo, T. T. T., Nguyen, N. T., Dang, T. T. H., Tran, D. L., Quan, D. P., Nguyen, X. N., Nguyen, X. P., et al. (2012) · Advances in Natural Sciences Nanoscience and Nanotechnology · doi:10.1088/2043-6262/3/2/025011 · Cited by 31
Turan, J., Kesik, M., Söylemez, S., Göker, S., Kolb, M., Bahadir, M., & Toppare, L. K. (2014) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2014.10.007 · Cited by 31
Kosminsky, L., & Bertotti, M. (1999) · Electroanalysis · doi:10.1002/(sici)1521-4109(199907)11:9 · Cited by 52
de Jesus, C. G., Lima, D., dos Santos, V., Wohnrath, K., & Pessôa, C. A. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.05.063 · Cited by 30
Cation Sensitivity of a Polypyrrole/Polyanion Composite Film Electrode
Momma, T., Komaba, S., Ōsaka, T., NAKAMURA, S., & Takemura, Y. (1995) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.68.1297 · Cited by 30
Hardcastle, J. L., Paterson, C. J., & Compton, R. G. (2001) · Electroanalysis · doi:10.1002/1521-4109(200107)13:11 · Cited by 60
Kafi, A. K. M., Lee, D., Park, S.-H., & Kwon, Y. (2006) · Microchemical Journal · doi:10.1016/j.microc.2006.07.007 · Cited by 29
The development of a novel urea sensor using polypyrrole
Hamilton, A., & Breslin, C. B. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.08.052 · Cited by 29
Conducting polymer-based impedimetric aptamer biosensor for in situ detection
Liao, W., Randall, B. L., Alba, N. A., & Cui, X. T. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2354-8 · Cited by 29
Cosnier, S., Fologea, D., Szunerits, S., & Marks, R. S. (2000) · Electrochemistry Communications · doi:10.1016/s1388-2481(00)00131-4 · Cited by 29
Acrylic Acid-Based Copolymers as Immobilization Matrix for Amperometric Biosensors
Neugebauer, S., Işık, S., Schulte, A., & Schuhmann, W. W. (2003) · Analytical Letters · doi:10.1081/al-120023626 · Cited by 29
Arslan, F., & BESKAN, U. (2013) · Artificial Cells Nanomedicine and Biotechnology · doi:10.3109/21691401.2013.812650 · Cited by 28
Sarauli, D., Xu, C., Dietzel, B., Schulz, B. W., & Lisdat, F. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00336e · Cited by 28
Çil, M., Böyükbayram, A. E., Kıralp, S., Toppare, L. K., & Yağcı, Y. (2006) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2006.12.005 · Cited by 28
Bioelectrochemical response of the polyaniline ascorbate oxidase electrode
Wang, H., & Mu, S. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00320-3 · Cited by 28
Development of PANI-PVS-GOD electrode by potentiometric method for determination of glucose
Gaikwad, P. D., Shirale, D. J., Savale, P. A., Datta, K. P., Ghosh, P., Pathan, A. J., Rabbani, G., & Shirsat, M. D. (2007) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)17089-1 · Cited by 28
Ching, M. K., Bakar, F. A., Salleh, A. B., Heng, L. Y., Wagiran, R., & Siddiquee, S. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)19575-7 · Cited by 27
Pilo, M. I., Farre, R., Lachowicz, J. I., Masolo, E., Panzanelli, A., Sanna, G., Senes, N., Sobral, A. I. F., & Spano, N. (2018) · Journal of Analytical Methods in Chemistry · doi:10.1155/2018/1849439 · Cited by 27
Zhang, L., Yuan, R., Huang, X., Chai, Y., & Cao, S. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2004.09.020 · Cited by 27
Malinauskas, A., & Holze, R. (1996) · Berichte der Bunsengesellschaft für physikalische Chemie · doi:10.1002/bbpc.19961001012 · Cited by 27
Development of a needle-type biosensor for intravascular glucose monitoring
Abdel‐Hamid, I., Atanasov, P., & Wilkins, E. S. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00172-v · Cited by 27
Amperometric Detection of Histamine with a Pyrroloquinoline‐Quinone Modified Electrode
Young, J. A., Jiang, X., & Kirchhoff, J. R. (2013) · Electroanalysis · doi:10.1002/elan.201300114 · Cited by 26
Applications of Conducting Polymers
Inzelt, G. (2012) · Monographs in electrochemistry · doi:10.1007/978-3-642-27621-7_7 · Cited by 26
Swann, M. J., Bloor, D., Haruyama, T., & Aizawa, M. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00087-0 · Cited by 26
Griffith, A., Glidle, A., & Cooper, J. M. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)83297-0 · Cited by 26
Self-citationConducting Polymer 3D Microelectrodes
Sasso, L., Vazquez, P., Vedarethinam, I., Castillo-León, J., Emnéus, J., & Svendsen, W. E. (2010) · Sensors · doi:10.3390/s101210986 · Cited by 25
Calvente, J. J., Narváez, A., Domı́nguez, E., & Andreu, R. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp030011p · Cited by 25
Kienle, S., Lingler, S., Kraas, W., Offenhäusser, A., Knol, W., & Jung, G. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00044-4 · Cited by 25
Ourari, A., Ouari, K., Khan, M. A., & Bouet, G. (2008) · Journal of Coordination Chemistry · doi:10.1080/00958970802178257 · Cited by 24
Wang, X., Sjöberg‐Eerola, P., Immonen, K., Bobacka, J., & Bergelin, M. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.02.005 · Cited by 24
Guschin, D. A., Shkil, H., & Schuhmann, W. W. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3052-x · Cited by 24
Craig, J. D., & O'Neill, R. D. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.08.025 · Cited by 24
A Microscopic, Continous, Optical Monitor for Interstitial Electrolytes and Glucose
Tohda, K., & Gratzl, M. (2003) · ChemPhysChem · doi:10.1002/cphc.200390025 · Cited by 24
A potentiometric polypyrrole‐based glucose biosensor
Trojanowicz, M., & Hitchman, M. L. (1996) · Electroanalysis · doi:10.1002/elan.1140080311 · Cited by 24
Design of novel molecular wires for realizing long-distance electron transfer
Albers, W. M., Lekkala, J. O., Jeuken, L. J. C., Canters, G. W., & Turner, A. P. F. (1997) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(96)05150-1 · Cited by 24
Electrochemical, luminescent and photographic characterisation of cavitation
Birkin, P. R., Power, J. F., Abdelsalam, M. E., & Leighton, T. G. (2003) · Ultrasonics Sonochemistry · doi:10.1016/s1350-4177(02)00155-4 · Cited by 24
Zhang, Z., Lei, C., Sun, W., Liu, H., & Deng, J. (1996) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(96)04873-5 · Cited by 24
Determination of the Biomolecular Composition of an Enzyme−Polymer Biosensor
Griffith, A., Glidle, A., Beamson, G., & Cooper, J. M. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp9633456 · Cited by 24
Self-citationSelf-wiring from tyrosinase to an electrode with redox polymers
Tatsuma, T., & Sato, T. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.05.020 · Cited by 24
Amperometric Enzyme Sensors based on Direct and Mediated Electron Transfer
Borgmann, S., Hartwich, G., Schulte, A., & Schuhmann, W. W. (2005) · Perspectives in bioanalysis · doi:10.1016/s1871-0069(05)01017-7 · Cited by 23
Olea, D., & Faure, C. (2003) · The Journal of Chemical Physics · doi:10.1063/1.1601598 · Cited by 23
Makowski, T., Kowalczyk, D., Fortuniak, W., Brzeziński, S., & Kręgiel, D. (2015) · Cellulose · doi:10.1007/s10570-015-0725-9 · Cited by 22
QSPR Study of Passivation by Phenolic Compounds at Platinum and Boron-Doped Diamond Electrodes
Teofilo, R. F., Kiralj, R., Ceragioli, H. J., Peterlevitz, A. C., Baranauskas, V., Kubota, L. T., & Ferreira, M. M. C. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2953588 · Cited by 22
Poly(1,8-diaminocarbazole) – A novel conducting polymer for sensor applications
Skompska, M., Chmielewski, M. J., & Tarajko, A. (2006) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.10.036 · Cited by 22
Electrochemistry of Electronically Conducting Polymer Films
Pickup, P. G. (2002) · Modern aspects of electrochemistry · doi:10.1007/0-306-46917-0_6 · Cited by 22
Tailored Polymers To Probe the Nature of the Bioelectrochemical Interface
Ryder, K. S., Morris, D. G., & Cooper, J. M. (1996) · Langmuir · doi:10.1021/la960440x · Cited by 22
Self-citationGuiomar, A. J., Evans, S. D., & Guthrie, J. T. (1997) · Supramolecular Science · doi:10.1016/s0968-5677(97)00013-8 · Cited by 22
Investigation of the origin of the glucose response in a glucose oxidase|polyaniline system
Skinner, N. G., & Hall, E. A. H. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(96)04799-7 · Cited by 22
Nguyen, H. B., Nguyen, V. C., Nguyễn, V. T., Le, H. D., Nguyen, V., Ngo, T. T. T., Quan, D. P., Nguyen, X. N., Phan, N. M., & Tran, D. L. (2013) · Advances in Natural Sciences Nanoscience and Nanotechnology · doi:10.1088/2043-6262/4/1/015013 · Cited by 21
Determination of 5‐Aminosalicylic Acid by Catalase‐Peroxidase Based Biosensor
Akkaya, A., Altuğ, Ç., Pazarlıoǧlu, N. K., & Dinçkaya, E. (2009) · Electroanalysis · doi:10.1002/elan.200904606 · Cited by 21
Klink, M. J., Iwuoha, E. I., & Ebenso, E. E. (2011) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)18195-8 · Cited by 21
Tsujimoto, M., Yabutani, T., Sano, A., Tani, Y., Murotani, H., Mishima, Y., Maruyama, K., Yasuzawa, M., & Motonaka, J. (2007) · Analytical Sciences · doi:10.2116/analsci.23.59 · Cited by 21
Warriner, K., Higson, S. P. J., & Vadgama, P. M. (1997) · Materials Science and Engineering C · doi:10.1016/s0928-4931(97)00067-2 · Cited by 21
Synthesis of protected derivatives of 3-pyrrolylalanine
Beecher, J. E., & Tirrell, D. A. (1998) · Tetrahedron Letters · doi:10.1016/s0040-4039(98)00722-9 · Cited by 21
Electrogenerated Poly(Chiral Dicarbazole) Films for the Reagentless Grafting of Enzymes
Cosnier, S., Marks, R. S., Lellouche, J., Perié, K., Fologea, D., & Szunerits, S. (2000) · Electroanalysis · doi:10.1002/1521-4109(200010)12:14 · Cited by 21
Permeability enhancement of electropolymerized thin organic films
Gros, P., Gibson, T. D., Bergel, A., & Comtat, M. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00338-0 · Cited by 21
Mayers, B. T., & Fry, A. J. (2006) · Organic Letters · doi:10.1021/ol052558n · Cited by 20
Siontorou, C. G., & Batzias, F. A. (2013) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2013.790339 · Cited by 20
Prospects of Organic Conducting Polymer Modified Electrodes: Enzymosensors
Singh, R. P. (2012) · International Journal of Electrochemistry · doi:10.1155/2012/502707 · Cited by 20
Millner, P. A., Hays, H. C. W., Vakurov, A. V., Pchelintsev, N. A., Billah, M. M., & Rodgers, M. A. (2009) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2009.01.011 · Cited by 20
Pałys, B., Marzec, M., & Rogalski, J. (2010) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2010.06.008 · Cited by 20
Labban, N., Wayu, M. B., Steele, C. M., Munoz, T. S., Pollock, J. A., Case, W. S., & Leopold, M. C. (2018) · Nanomaterials · doi:10.3390/nano9010042 · Cited by 20
Yang, Y., & Lin, Z. (1996) · Synthetic Metals · doi:10.1016/0379-6779(96)80110-x · Cited by 20
Electrode Reactions of Catechol at Tyrosinase‐Immobilized Latex Suspensions
Rijiravanich, P., Aoki, K., Chen, J., Surareungchai, W., & Somasundrum, M. (2004) · Electroanalysis · doi:10.1002/elan.200302798 · Cited by 20
Modelling the Transport and Kinetics of Electroenzymes at the Electrode/Solution Interface
Lyons, M. E. G. (2006) · Sensors · doi:10.3390/s6121765 · Cited by 20
Immobilization of Uricase Upon Polypyrrole-Ferrocenium Film
Çete, S., Yaşar, A., & Arslan, F. (2007) · Artificial Cells Blood Substitutes and Biotechnology · doi:10.1080/10731190701378634 · Cited by 20
Duong, N. B., Wang, C., Huang, L. Z., Fang, W. T., & Yang, H. (2019) · Journal of Power Sources · doi:10.1016/j.jpowsour.2019.05.001 · Cited by 20
Marx, K. A. (2006) · Springer eBooks · doi:10.1007/5346_033 · Cited by 20
Effects of conducting polymers on immobilized galactose oxidase
Jinqing, K., Xue, H., Mu, S., & Hong, C. (1997) · Synthetic Metals · doi:10.1016/s0379-6779(97)80110-5 · Cited by 20
A polypyrrole-biotin based biosensor: elaboration and characterization
Torres‐Rodríguez, L. M., Billon, M., Roget, A., & Bidan, G. (1999) · Synthetic Metals · doi:10.1016/s0379-6779(98)01053-4 · Cited by 20
Dopamine and Glucose Sensors Based on Glassy Carbon Electrodes Modified with Melanic Polymers
González, R., Sánchez, A., Chicharro, M., Rubianes, M. D., & Rivas, G. A. (2004) · Electroanalysis · doi:10.1002/elan.200302939 · Cited by 20
Marx, K. A., & Zhou, T. (2002) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(02)00644-7 · Cited by 20
Poly (Amphiphilic Pyrr0Le)-PPO Electrodes for Organic-Phase Enzymatic Assay
Coche‐Guérente, L., Cosnier, S., & Innocent, C. (1995) · Analytical Letters · doi:10.1080/00032719508002675 · Cited by 20
Martı́nez, B., Odier, H., Coetsier, C., & Serrano, K. G. (2023) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2023.110203 · Cited by 19
Olea, D., Moreau, P., & Faure, C. (2007) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2007.03.027 · Cited by 19
Ling, D., Guo-qi, W., Wang, C., Wang, F., & Song, G. (2000) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(00)00242-8 · Cited by 19
Garcı́a-Moreno, E., Ruiz, M. A., Barbas, C., & Pingarrón, J. M. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01311-3 · Cited by 19
Screen-printed microsystems for the ultrasensitive electrochemical detection of alkaline phosphatase
Santiago, L. M., Bejarano-Nosas, D., Lozano-Sánchez, P., & Katakis, I. (2010) · The Analyst · doi:10.1039/c0an00001a · Cited by 18
Electrochemistry of Conductive Polymers
Sharma, H., & Park, S. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639021 · Cited by 18
Curulli, A., Carelli, I., Trischitta, O., & Palleschi, G. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00060-2 · Cited by 18
Lindfors, T., Lähdesmäki, I., & Ivaska, A. U. (1996) · Analytical Letters · doi:10.1080/00032719608002250 · Cited by 18
Practical and theoretical evaluation of an alternative geometry enzyme electrode
Gooding, J. J., & Hall, E. A. H. (1996) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(96)04752-3 · Cited by 18
Tatsuma, T., Ariyama, K., & Oyama, N. (1996) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00451-3 · Cited by 18
Physical study of film-forming acrylate emulsion polymers for biosensor applications
Gooding, J. J., Hall, C. E., & Hall, E. A. H. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00282-1 · Cited by 18
Chemical Sensors Based on Conducting Polymers
Bobacka, J., & Ivaska, A. U. (2010) · doi:10.1002/9783527630592.ch9 · Cited by 18
Multiscale-Tailored Bioelectrode Surfaces for Optimized Catalytic Conversion Efficiency
Côme, Y. B. S., Lalo, H., Wang, Z., Etienne, M., Gajdzik, J., Kohring, G., Walcarius, A., Hempelmann, R., & Kuhn, A. (2011) · Langmuir · doi:10.1021/la201930m · Cited by 17
Quintero-Jaime, A. F., Conzuelo, F., Cazorla‐Amorós, D., & Morallón, E. (2021) · Talanta · doi:10.1016/j.talanta.2021.122386 · Cited by 17
COMPOSITE HYDROGELS CONTAINING POLYPYRROLE AS SUPPORT MEMBRANES FOR AMPEROMETRIC ENZYME BIOSENSORS
Guiseppi‐Elie, A., Brahim, S. I., & Narinesingh, D. (2001) · Journal of Macromolecular Science Part A · doi:10.1081/ma-100108406 · Cited by 17
Chapter 7 New materials for biosensors, biochips and molecular bioelectronics
Andreescu, D., Andreescu, S., & Sadik, O. A. (2005) · Comprehensive analytical chemistry · doi:10.1016/s0166-526x(05)44007-6 · Cited by 17
Fabrication of bioanode by using electrically conducting polythiophene via entrapment technique
Inamuddin, I., Beenish, & Naushad, M. (2015) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-015-0116-9 · Cited by 16
Thin films of substituted polyanilines: interactions with biomolecular systems
Sarauli, D., Xu, C., Dietzel, B., Stiba, K., Leimkühler, S., Schulz, B. W., & Lisdat, F. (2012) · Soft Matter · doi:10.1039/c2sm07261k · Cited by 16
Li, T., & Wang, E. (1997) · Electroanalysis · doi:10.1002/elan.1140091516 · Cited by 16
Kang, T., Shen, G., & Yu, R. (1997) · Analytical Letters · doi:10.1080/00032719708006415 · Cited by 16
Marx, K. A., Lee, J. S., & Sung, C. (2004) · Biomacromolecules · doi:10.1021/bm049793y · Cited by 16
Electrosynthesized, non-conducting films of poly(2-naphthol): electrochemical and XPS investigations
Ciriello, R., Guerrieri, A., Pavese, F., & Salvi, A. M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2325-0 · Cited by 15
Emerging Nanomaterials for Analytical Detection
Alarcón-Ángeles, G., Álvarez‐Romero, G. A., & Merkoçi, A. (2016) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2016.03.022 · Cited by 15
A study on electrodeposition of glucose oxidase from low conductivity solutions
Ammam, M., & Fransaer, J. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.08.050 · Cited by 15
Enzyme Immobilization and Mediation with Osmium Redox Polymers
VandeZande, G. R., Olvany, J. M., Rutherford, J. L., & Rasmussen, M. (2016) · Methods in molecular biology · doi:10.1007/978-1-4939-6499-4_13 · Cited by 15
Design of a biosensor based on 1-(4-nitrophenyl)-2,5-di(2-thienyl)-1H pyrrole
Tuncagil, S., Varış, S., & Toppare, L. K. (2009) · Journal of Molecular Catalysis B Enzymatic · doi:10.1016/j.molcatb.2009.06.002 · Cited by 15
Metadata
- Authors
- Barlett, P. N., & Cooper, J. M.
- Affiliations
- University of Southampton (GB)
- University of Glasgow (GB)
- ORCID
- Cooper, J.M.
- Venue
- Journal of Electroanalytical Chemistry
- Publisher
- Elsevier BV
- Published
- 1993-12
- Volume
- 362
- Issue
- 1-2
- Pages
- 1-12
- ISSN
- 1572-6657 (ISSN-L)
- OpenAlex
- W1987410104
- Cited by
- 472
- References
- 72
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 5 · 2023: 5 · 2022: 3 · 2021: 3 · 2020: 6 · 2019: 9 · 2018: 9 · 2017: 6 · 2016: 12 · 2015: 8 · 2014: 16 · 2013: 22 · 2012: 11
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Electroanalytical Chemistry (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Keywords
- enzyme immobilization, electropolymerization, conducting polymer films, electrode surface
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review