The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Self-diffusion NMR imaging using stimulated echoes
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Use of the Stimulated Echo in NMR Diffusion Studies
Tanner, J. E. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1673336 · Cited by 1,645
Restricted Self-Diffusion of Protons in Colloidal Systems by the Pulsed-Gradient, Spin-Echo Method
Tanner, J. E., & Stejskal, E. O. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670306 · Cited by 867
Diffusion and Nuclear Spin Relaxation in Water
Simpson, J. H., & Carr, H. Y. (1958) · Physical Review · doi:10.1103/physrev.111.1201 · Cited by 444
Water self-diffusion in nonionic surfactant solutions. Hydration and obstruction effects
Nilsson, P. G., & Lindman, B. (1983) · The Journal of Physical Chemistry · doi:10.1021/j100246a041 · Cited by 220
Effects of Diffusion in Nuclear Magnetic Resonance Spin-Echo Experiments
Woessner, D. E. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731821 · Cited by 220
Frahm, J., Merboldt, K. D., Hänicke, W., & Haase, A. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90033-2 · Cited by 192
Self-citationRestricted Diffusion in Biophysical Systems
Cooper, R. L., Chang, D. B., Young, A. C., Martin, C. J., & Ancker-Johnson, B. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85904-7 · Cited by 183
Cited by
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Basser, P. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080707 · Cited by 1,519
Dipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
Metadata
- Authors
- Merboldt, K.-D., Hanicke, W., & Frahm, J.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1985-10
- Volume
- 64
- Issue
- 3
- Pages
- 479-486
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2051019611
- Cited by
- 307
- References
- 11
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-diffusion NMR imaging using stimulated echoes. https://app.cochat.ai/papers/10.1016/0022-2364(85)90111-8
- The paper
- Merboldt, K.-D., Hanicke, W., & Frahm, J. (1985). Self-diffusion NMR imaging using stimulated echoes. Journal of Magnetic Resonance (1969). https://doi.org/10.1016/0022-2364(85)90111-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.