Variable-rate selective excitation
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A procedure is introduced for refabricating any spatially selective excitation pulse to reduce its SAR while preserving its duration and slice profile. Called variable-rate selective excitation, the procedure allows for a variable trade-off of RF amplitude for duration at each sample of the pulse. SAR reduction of 50% is possible with only a mild smearing of the off resonance slice profile. Experimental slice profiles verify the principle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computer methods for mathematical computations
Forsythe, G. E., Malcolm, M. A., & Moler, C. (1977) · UCLA Biblioteca de Ingenieria Civil · Cited by 2,683
Introduction to linear and nonlinear programming
Polak, E. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100535 · Cited by 2,100
Introduction to linear and nonlinear programming
Luenberger, D. G. (1973) · Medical Entomology and Zoology · Cited by 1,915
Mansfield, P., & Morris, P. G. (1982) · CERN Document Server (European Organization for Nuclear Research) · Cited by 839
Highly selective and π pulse generation
Silver, M. S., Joseph, R. I., & Hoult, D. I. (1984) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(84)90181-1 · Cited by 515
Optimal Control Solutions to the Magnetic Resonance Selective Excitation Problem
Conolly, S., Nishimura, D., & Macovski, A. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307754 · Cited by 278
Self-citationPlewes, D. B. (1983) · Radiology · doi:10.1148/radiology.147.2.472 · Cited by 156
Cited by
Dai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
The Return of the Frequency Sweep: Designing Adiabatic Pulses for Contemporary NMR
Garwood, M., & DelaBarre, L. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2340 · Cited by 952
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Practical T2 quantitation for clinical applications
Poon, C. S., & Henkelman, R. M. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020512 · Cited by 393
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
Parallel RF transmission in MRI
Katscher, U., & Börnert, P. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1049 · Cited by 214
“, the impact of the k-space trajectory on the occurring SAR (43) or designing three-dimensional trajectories exciting slices with a sharp profile and a low resolution in-plane homogeneity correction (44).”
BackgroundVariable‐rate selective excitation for rapid MRI sequences
Hargreaves, B. A., Cunningham, C. H., Nishimura, D. G., & Conolly, S. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20168 · Cited by 189
“The VERSE (8) technique is used to distort the RF waveform to match a time-varying slab-select gradient waveform.”
BackgroundMethodSelf-citationReduction of susceptibility artifact in gradient‐echo imaging
Cho, Z. H., & Ro, Y. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230120 · Cited by 165
Qualitative and quantitative ultrashort‐TE MRI of cortical bone
Du, J., & Bydder, G. M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2906 · Cited by 159
Metadata
- Authors
- Conolly, S., Nishimura, D., Macovski, A., & Glover, G.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1988-07
- Volume
- 78
- Issue
- 3
- Pages
- 440-458
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2077035487
- Cited by
- 321
- References
- 7
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.