Pulsed field gradient stimulated echo methods for improved NMR diffusion measurements in heterogeneous systems
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The NMR pulsed magnetic field gradient stimulated echo technique of Tanner is especially useful for measuring the translational diffusion coefficient, D, of the resonant nucleus in materials where T1 ⪢ T2. However, in heterogeneous systems having components with dissimilar magnetic susceptibilities, a distribution of background gradients, g0, may cause excessive signal (echo) attenuation and a systematic error in the measurement of D. Three new stimulated echo sequences involving applied field gradient pulses, of amplitude ga, together with RF pulses, are described. For all of these sequences the echo attenuation and systematic error caused by g0 and g0ga terms, respectively, are greatly reduced. For one of the sequences, this reduction can be realized with gradient pulses of a single polarity. With bipolar (alternating) gradient pulses the cross term can be made to vanish, with the correct choice of conditions, for all three of the sequences. Two of the new sequences have been tested experimentally by means of D measurements involving 1H signals in bulk glycerol (homogeneous) and in granular TaH0.73 (heterogeneous) samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Use of the Stimulated Echo in NMR Diffusion Studies
Tanner, J. E. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1673336 · Cited by 1,645
Bloch Equations with Diffusion Terms
Torrey, H. C. (1956) · Physical Review · doi:10.1103/physrev.104.563 · Cited by 1,216
Karlicek, R. F., & Lowe, I. J. (1980) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(80)90095-5 · Cited by 234
Williams, W. D., Seymour, E. F. W., & Cotts, R. M. (1978) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(78)90189-0 · Cited by 75
Self-citation
Cited by
Diffusion ordered nuclear magnetic resonance spectroscopy: principles and applications
Johnson, C. S. (1999) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(99)00003-5 · Cited by 1,679
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Molecular diffusion, tissue microdynamics and microstructure
Bihan, D. L. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080711 · Cited by 497
Blümich, B., Perlo, J., & Casanova, F. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2007.10.002 · Cited by 469
Forse, A. C., Griffin, J. M., Merlet, C., Carretero-Gonzalez, J., Raji, A.-R. O., Trease, N. M., & Grey, C. P. (2017) · Nature Energy · doi:10.1038/nenergy.2016.216 · Cited by 407
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Dertinger, T., Pacheco, V., von der Hocht, I., Hartmann, R., Gregor, I., & Enderlein, J. (2007) · ChemPhysChem · doi:10.1002/cphc.200600638 · Cited by 345
Diffusion and Interfacial Transport of Water in Nafion
Zhao, Q., Majsztrik, P., & Benziger, J. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp1112125 · Cited by 301
Low-field permanent magnets for industrial process and quality control
Mitchell, J., Gladden, L. F., Chandrasekera, T. C., & Fordham, E. J. (2014) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.09.001 · Cited by 300
Intermolecular interaction as investigated by NOE and diffusion studies
Brand, T., Cabrita, E. J., & Berger, S. (2005) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2005.04.003 · Cited by 267
Diffusion MRI: Precision, accuracy and flow effects
Conturo, T. E., McKinstry, R. C., Aronovitz, J. A., & Neil, J. J. (1995) · NMR in Biomedicine · doi:10.1002/nbm.1940080706 · Cited by 211
Flow and dispersion in porous media: Lattice‐Boltzmann and NMR studies
Manz, B., Gladden, L. F., & Warren, P. B. (1999) · AIChE Journal · doi:10.1002/aic.690450902 · Cited by 206
Elsayed, M., Isah, A., Hiba, M., Hassan, A., Al-Garadi, K., Mahmoud, M., El-Husseiny, A., & Radwan, A. E. (2022) · Journal of Petroleum Exploration and Production Technology · doi:10.1007/s13202-022-01476-3 · Cited by 203
Mckay, R. T. (2011) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.20223 · Cited by 191
Magnetic resonance imaging in laboratory petrophysical core analysis
Mitchell, J., Chandrasekera, T. C., Holland, D. J., Gladden, L. F., & Fordham, E. J. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.01.003 · Cited by 188
Mass transfer in nanofluids: A review
Ashrafmansouri, S.-S., & Nasr Esfahany, M. (2014) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2014.03.017 · Cited by 176
“In their work, the diffusion coefficient was measured using a pulsed gradient stimulated echo sequence with bipolar gradients, also known as the Cotts 13-interval pulse sequence [23,32].”
MethodLateral Diffusion Rates of Lipid, Water, and a Hydrophobic Drug in a Multilamellar Liposome
Gaede, H. C., & Gawrisch, K. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74603-7 · Cited by 161
“37 T/m with a stimulated echo sequence using sine-shaped bipolar gradient pulses (Cotts et al., 1989) of 5-ms duration.”
MethodInfluentialSpreading waves of decreased diffusion coefficient lifter cortical stimulation in the rat brain
Latour, L. L., Hasegawa, Y., Formato, J. E., Fisher, M., & Sotak, C. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320207 · Cited by 136
Water Transport in MgSO4·7H2O During Dehydration in View of Thermal Storage
Donkers, P. A. J., Beckert, S., Pel, L., Stallmach, F., Steiger, M., & Adan, O. C. G. (2015) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.5b08730 · Cited by 83
The N-terminal order-disorder transition is a critical determinant for a metamorphosis of IscU
Na, J., Heo, J., Jeong, M., Kim, B. S., Ji, S., Ko, Y. H., Shafiei, A., Baldir, N., DeMirci, H., Yu, W., et al. (2025) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2025.146969 · Cited by 3
Metadata
- Authors
- Cotts, R. M., Hoch, M. J. R., Sun, T., & Markert, J. T.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1989-06
- Volume
- 83
- Issue
- 2
- Pages
- 252-266
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2022803091
- Cited by
- 692
- References
- 6
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.