Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: A meta-analysis
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To use a meta-analysis of all published randomized trials to determine whether the use of continuous electronic fetal heart rate monitoring (EFM) as the main method of intrapartum fetal surveillance is associated with improved pregnancy outcome compared to intermittent auscultation. DATA SOURCES: We used the MEDLINE data base and reference lists of articles to identify all published randomized trials of EFM versus intermittent auscultation. METHODS OF STUDY SELECTION: A total of nine randomized trials published in peer-review journals were identified. The selection criterion was the use of EFM or intermittent auscultation as the main intrapartum fetal surveillance technique. DATA EXTRACTION AND SYNTHESIS: A total of 18,561 patients were included in the nine published randomized trials, 9398 in the EFM group and 9163 in the auscultation group. Measures of pregnancy outcome included cesarean delivery, cesarean for suspected fetal distress, overall use of forceps or vacuum, use of forceps or vacuum for suspected fetal distress, overall perinatal mortality, and perinatal mortality due to fetal hypoxia (intrapartum or early neonatal death) attributable to the method of intrapartum monitoring. The meta-analysis showed that the patients monitored electronically had a significantly higher overall cesarean rate (odds ratio [OR] 1.53, 95% confidence interval [CI] 1.17-2.01), higher cesarean rate for fetal distress (OR 2.55, 95% CI 1.81-3.53), overall increased use of forceps or vacuum (OR 1.23, 95% CI 1.02-1.49), increased use of forceps or vacuum for suspected fetal distress (OR 2.50, 95% CI 1.97-3.18), and decreased perinatal mortality due to fetal hypoxia (OR 0.41, 95% CI 0.17-0.98). CONCLUSION: Electronic fetal monitoring is associated with increased rates of surgical intervention and decreased perinatal mortality due to fetal hypoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Dublin randomized controlled trial of intrapartum fetal heart rate monitoring
MacDonald, D., Grant, A., Sheridan-Pereira, M., Boylan, P., & Chalmers, I. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90619-2 · Cited by 631
A controlled trial of the differential effects of intrapartum fetal monitoring
Haverkamp, A. D., Orleans, M., Langendoerfer, S., McFee, J., Murphy, J., & Thompson, H. E. (1979) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)33082-4 · Cited by 392
The evaluation of continuous fetal heart rate monitoring in high-risk pregnancy
Haverkamp, A. D., Thompson, H. E., McFee, J. G., & Cetrulo, C. (1976) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(76)90565-2 · Cited by 324
The Bristol third stage trial: active versus physiological management of third stage of labour.
Prendiville, W. J., Harding, J. E., Elbourne, D. R., & Stirrat, G. M. (1988) · BMJ · doi:10.1136/bmj.297.6659.1295 · Cited by 306
Leveno, K. J., Cunningham, F. G., Nelson, S., Roark, M., Williams, M. L., Guzick, D., Dowling, S., Rosenfeld, C. R., & Buckley, A. (1986) · New England Journal of Medicine · doi:10.1056/nejm198609043151004 · Cited by 226
Controlled trial of fetal intensive care
Renou, P., Chang, A., Anderson, I., & Wood, C. (1976) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(76)90641-4 · Cited by 202
PRENDIVILLE, W., ELBOURNE, D., & CHALMERS, I. (1988) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1988.tb06475.x · Cited by 201
Intrapartum fetal heart rate monitoring
Krebs, H. B., Petres, R. E., Dunn, L. J., Jordaan, H. V. F., & Segreti, A. (1980) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)32835-6 · Cited by 166
Vintzileos, A. M., Antsaklis, A. J., Varvarigos, I., Papas, C., Sofatzis, I., & Montgomery, J. T. (1993) · PubMed · Cited by 159
Self-citationRandomised controlled trial of intrapartum fetal heart rate monitoring
Mahomed, K., Nyoni, R., Mulambo, T., Kasule, J., & Jacobus, E. (1994) · BMJ · doi:10.1136/bmj.308.6927.497 · Cited by 96
Electronic fetal monitoring and later outcome.
Paneth, N., Bommarito, M., & Stricker, J. (1993) · PubMed · Cited by 51
Cited by
Publication and related bias in meta-analysis
Sterne, J. A. C., Gavaghan, D., & Egger, M. (2000) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(00)00242-0 · Cited by 2,282
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography
Ayres‐de‐Campos, D., Spong, C. Y., Chandraharan, E., & Panel, F. I. F. M. E. C. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2015.06.020 · Cited by 911
Uncertain Value of Electronic Fetal Monitoring in Predicting Cerebral Palsy
Nelson, K. B., Dambrosia, J. M., Ting, T. Y., & Grether, J. K. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603073341001 · Cited by 532
A Review of Fetal ECG Signal Processing Issues and Promising Directions
Sameni (2010) · The Open Pacing, Electrophysiology & Therapy Journal · doi:10.2174/1876536x01003010004 · Cited by 410
Metadata
- Authors
- Vintzileos, A.
- Venue
- Obstetrics & Gynecology
- Published
- 1995-01
- Volume
- 85
- Issue
- 1
- Pages
- 149-155
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2017557162
- Cited by
- 271
- References
- 11
- FWCI
- 14.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.