The spatial resolution capacity of human foveal retina
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
An image on the retina of a human eye enters the visual system through an array of photoreceptors that sets the boundaries on the spatial detail available for neural representation. In order to investigate the extent to which the input spatial detail is preserved by the human neural system, we compare the anatomical spatial limits as determined by the Nyquist frequency, the highest spatial frequency reconstructable from the cone array, and measures of human acuity, the minimum angle resolvable. We find that the anatomical Nyquist limits determined along the temporal horizontal meridian of a well-studied human retina (Curcio, Sloan, Packer, Hendrickson & Kalina, 1987b) offer a reasonable prediction of human acuity within the retinal region extending from slightly off the exact foveal center to about 2.0 deg of retinal eccentricity. However, we find a narrow peak of anatomical resolution at the foveal center where the acuity appears to be overestimated by cone spacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
Self-citationComputational vision and regularization theory
Poggio, T., Torre, V., & Koch, C. (1985) · Nature · doi:10.1038/317314a0 · Cited by 1,412
Topography of the Layer of Rods and Cones in the Human Retina
(1937) · Journal of the American Medical Association · doi:10.1001/jama.1937.02780030070033 · Cited by 817
A qualitative and quantitative analysis of the human fovea during development
Yuodelis, C., & Hendrickson, A. (1986) · Vision Research · doi:10.1016/0042-6989(86)90143-4 · Cited by 704
Helmholtz's treatise on physiological optics
(1924) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(24)90484-4 · Cited by 696
Distribution of Cones in Human and Monkey Retina: Individual Variability and Radial Asymmetry
Curcio, C. A., Sloan, K. R., Packer, O., Hendrickson, A. E., & Kalina, R. E. (1987) · Science · doi:10.1126/science.3576186 · Cited by 585
Self-citationPerry, V. H., & Cowey, A. (1985) · Vision Research · doi:10.1016/0042-6989(85)90004-5 · Cited by 494 · cited 2×
“A similar retinal topography has also been observed in other human and monkey retinas (IZlsterberg, 1935; Miller, 1979; Perry & Cowey, 1985; de Monasterio et al., 1985; Hirsch & Miller, 1987; Ahnelt et al., 1987; Schein, 1988).”
BackgroundNon-linear projection of the retinal image in a wide-angle schematic eye.
Drasdo, N., & Fowler, C. W. (1974) · British Journal of Ophthalmology · doi:10.1136/bjo.58.8.709 · Cited by 301 · cited 1×
“An alternative schematic eye yields a conversion factor of 280 ,um/deg which would increase the average center-to-center spacings reported here by about 3.5% and is within the estimated error of the means (Drasdo & Fowler, 1974).”
BackgroundInfluential
Cited by
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
Self-citationDistribution and morphology of human cone photoreceptors stained with anti‐blue opsin
Curcio, C. A., Allen, K. A., Sloan, K. R., Lerea, C. L., Hurley, J. B., Klock, I. B., & Milam, A. H. (1991) · Journal of Comparative Neurology · doi:10.1002/cne.903120411 · Cited by 629
Self-citationArtificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
In Vivo Imaging of Human Cone Photoreceptor Inner Segments
Scoles, D., Sulai, Y. N., Langlo, C. S., Fishman, G. A., Curcio, C. A., Carroll, J., & Dubra, A. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14542 · Cited by 380
Self-citationOrganization of the human trichromatic cone mosaic
Hofer, H., Carroll, J., Neitz, J., Neitz, M., & Williams, D. R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2414-05.2005 · Cited by 364
Photoreceptor topography in ageing and age-related maculopathy
Curcio, C. A. (2001) · Eye · doi:10.1038/eye.2001.140 · Cited by 304
Self-citationSimulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
“The subjects' visual acuity with the simulator depended primarily on pixel spacing, much as the spatial resolution of the eye depends on receptor density in the retina (18).”
BackgroundWatson, A. B. (2014) · Journal of Vision · doi:10.1167/14.7.15 · Cited by 197
“In consequence the mRGC likely set an upper bound on the spatial resolution of human vision, especially at low temporal frequencies (Hirsch & Curcio, 1989; Merigan & Eskin, 1986; Merigan & Katz, 1990; Rossi & Roorda, 2010; Thibos, Cheney, &Walsh, 1987).”
BackgroundThe Evolution of High Visual Acuity in the Anthropoidea
Kirk, E. C., & Kay, R. F. (2004) · Anthropoid Origins · doi:10.1007/978-1-4419-8873-7_20 · Cited by 189
Adaptive Optics Ophthalmoscopy
Roorda, A., & Duncan, J. L. (2015) · Annual Review of Vision Science · doi:10.1146/annurev-vision-082114-035357 · Cited by 168
Diverse Cell Types, Circuits, and Mechanisms for Color Vision in the Vertebrate Retina
Thoreson, W. B., & Dacey, D. M. (2019) · Physiological Reviews · doi:10.1152/physrev.00027.2018 · Cited by 167
“It is well established that foveal cone spacing sets the limit on human spatial resolution (191, 391).”
BackgroundVisual optics and retinal cone topography in the common marmoset (Callithrix jacchus)
Troilo, D., Rowland, H. C., & Judge, S. J. (1993) · Vision Research · doi:10.1016/0042-6989(93)90038-x · Cited by 165
Colour is what the eye sees best
Chaparro, A., Stromeyer, C. F., Huang, E. P., Kronauer, R. E., & Eskew, R. T. (1993) · Nature · doi:10.1038/361348a0 · Cited by 164
Eye Movement Control During Reading: Foveal Load and Parafoveal Processing
Schroyens, W., Vitu, F., Brysbaert, M., & D'Ydewalle, G. (1999) · The Quarterly Journal of Experimental Psychology A · doi:10.1080/027249899390909 · Cited by 159
A Simple and Light-Weight Attention Module for Convolutional Neural Networks
Park, J., Woo, S., Lee, J.-Y., & Kweon, I. S. (2020) · International Journal of Computer Vision · doi:10.1007/s11263-019-01283-0 · Cited by 159
“For example, the resolution at the foveal center of human eyes is higher than surrounding areas (Hirsch and Curcio 1989).”
BackgroundAdaptive-optics imaging of human cone photoreceptor distribution
Chui, T. Y., Song, H., & Burns, S. A. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.003021 · Cited by 159
STARNES, A. C., HUISINGH, C., MCGWIN, G., SLOAN, K. R., ABLONCZY, Z., SMITH, R. T., CURCIO, C. A., & ACH, T. (2016) · Visual Neuroscience · doi:10.1017/s0952523815000310 · Cited by 46
“The spacing and geometry of cone packing is optimally balanced for resolution without aliasing except under specifi c circumstances (Hirsch & Curcio, 1989 ; Provis et al., 2013 ).”
BackgroundSelf-citation
Metadata
- Authors
- Hirsch, J., & Curcio, C. A.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1989
- Volume
- 29
- Issue
- 9
- Pages
- 1095-1101
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2047482416
- Cited by
- 250
- References
- 32
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.