Images of cone photoreceptors in the living human eye
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Though the photoreceptor mosaic has been imaged through the intact optics of the eyes of several species, it has not been clear whether individual photoreceptors can be resolved in the living human eye. We have constructed a high-resolution fundus camera and have resolved cones with a spacing as small as 3.5 microns in single images of the fundus. The high contrast of these images implies that almost all the light returning from the retina at this wavelength (555 nm) has passed through the apertures of foveal cones. The average power spectra of our retinal images show that it is possible to recover spatial frequencies as high as 150 c/deg in eyes with normal optical quality, a conclusion that was confirmed with estimates of the optical quality of these eyes obtained with a Hartmann-Shack wavefront sensor. These results emphasize the superiority of the eye's optics over the spatial sampling limits of the retina when the eye's optical quality is optimized. They also show that it would be possible to routinely resolve retinal structures as small as photoreceptors in the normal living eye if its aberrations could be corrected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Sensory Physiology
Sanders, M. D. (1975) · British Journal of Ophthalmology · doi:10.1136/bjo.59.2.111-c · Cited by 7,166
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167 · cited 3×
“The cone mosaic was simulated by taking cone locations from micrographs of excised human retina (Curcio et al., 1990) at four retinal eccentricities (foveal center, 0.”
BackgroundMethodInfluentialOptical and retinal factors affecting visual resolution.
Campbell, F. W., & Green, D. G. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007784 · Cited by 1,595 · cited 1×
“However, estimates of the eye's modulation transfer function hint that this decline occurs only at low spatial frequencies, and that high frequencies are actually better imaged with large pupils than with small ones (Campbell & Green, 1965; Campbell & Gubisch, 1966).”
BackgroundLaser Speckle and Related Phenomena
(1975) · Topics in Applied Physics · doi:10.1007/978-3-662-43205-1 · Cited by 1,330
(1958) · Archives of Ophthalmology · doi:10.1001/archopht.1958.00940070195028 · Cited by 1,226
Liang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195 · cited 2×
“…in a particular eye (Dreher et al., 1989), provides a promising way to achieve diffraction-limited fundus imaging through a dilated pupil, particularly since it is now possible to measure the eye's wave aberration with an automated wavefront sensor (Liang et al., 1994; Liang & Williams, 1995).”
BackgroundMethodSelf-citationTyson, R. K. (2015) · CRC Press eBooks · doi:10.1201/b19712 · Cited by 864
Optical quality of the human eye
Campbell, F. W., & Gubisch, R. W. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008056 · Cited by 810 · cited 1×
“However, estimates of the eye's modulation transfer function hint that this decline occurs only at low spatial frequencies, and that high frequencies are actually better imaged with large pupils than with small ones (Campbell & Green, 1965; Campbell & Gubisch, 1966).”
BackgroundWehner, R. (1981) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-67868-4_4 · Cited by 702
(1991) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(91)90509-b · Cited by 669
Aliasing in human foveal vision
Williams, D. R. (1985) · Vision Research · doi:10.1016/0042-6989(85)90113-0 · Cited by 277
Self-citationPopular lectures on scientific subjects
Helmholtz, H. L. F., & Atkinson, E. (1873) · D. Appleton eBooks · doi:10.5962/bhl.title.29497 · Cited by 259
Perrett, D. (1991) · Endeavour · doi:10.1016/0160-9327(91)90174-a · Cited by 232
Cordes, F. C. (1958) · American Journal of Ophthalmology · doi:10.1016/0002-9394(58)90699-8 · Cited by 231
Spectral Consequences of Photoreceptor Sampling in the Rhesus Retina
Yellott, J. I. (1983) · Science · doi:10.1126/science.6867716 · Cited by 224
Vision Science and its Applications
Howland, H. C., Tyler, C. J., Birch, E. E., & Rosenberg, R. (1996) · Optics and Photonics News · Cited by 222
Objective technique for the determination of monochromatic aberrations of the human eye
Walsh, G., Howland, H. C., & Charman, W. N. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000987 · Cited by 220 · cited 1×
“The large individual differences in optical quality seen here, even when defocus and astigmatism are corrected, confirm large individual differences in MTF reported by Walsh et al. (1984).”
ResultModulation transfer of the human eye as a function of retinal eccentricity
Navarro, R., Williams, D. R., & Artal, P. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000201 · Cited by 218
Self-citationSpectral analysis of spatial sampling by photoreceptors: Topological disorder prevents aliasing
Yellott, J. I. (1982) · Vision Research · doi:10.1016/0042-6989(82)90086-4 · Cited by 213
Speckle Removal by a Slowly Moving Diffuser Associated with a Motionless Diffuser
LOWENTHAL, S., & JOYEUX, D. (1971) · Journal of the Optical Society of America · doi:10.1364/josa.61.000847 · Cited by 192 · cited 2×
“The beam then passed through two adjacent counter-rotating phase diffusers (Lowenthal & Joyeux, 1971) that scattered the light in a broad range of directions, making the field spatially incoherent.”
BackgroundInfluentialPhotoreceptor diameter and spacing for highest resolving power
Snyder, A. W., & Miller, W. H. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.000696 · Cited by 188
A visual nonlinearity fed by single cones
MacLeod, D. I. A., Williams, D. R., & Makous, W. L. (1992) · Vision Research · doi:10.1016/0042-6989(92)90144-8 · Cited by 177 · cited 2×
“The value of 0.48 was taken from psychophysical estimates of the cone aperture using a distortion product technique (MacLeod et al., 1992; Chen et al., 1993).”
BackgroundMethodSelf-citationOff-axis image quality in the human eye
Jennings, J. A. M., & Charman, W. N. (1981) · Vision Research · doi:10.1016/0042-6989(81)90091-2 · Cited by 176 · cited 1×
“…convincing evidence for photoreceptors at larger eccentricities despite the fact that cone size and spacing continue to grow while the optical quality of the eye declines more slowly over this range of retinal locations (Jennings & Charman, 1981; Navarro et al., 1993; Williams et al., in press).”
BackgroundTopography of the foveal cone mosaic in the living human eye
Williams, D. R. (1988) · Vision Research · doi:10.1016/0042-6989(88)90185-x · Cited by 159 · cited 1×
“The solid line shows estimates of cone spacing based on psychophysical observations of aliasing with interference fringes (Williams, 1988).”
BackgroundSelf-citationOff-axis optical quality and retinal sampling in the human eye
Williams, D. R., Artal, P., Navarro, R., McMahon, M. J., & Brainard, D. H. (1996) · Vision Research · doi:10.1016/0042-6989(95)00182-4 · Cited by 155
Self-citationRefraction, aliasing, and the absence of motion reversals in peripheral vision
Artal, P., Derrington, A. M., & Colombo, E. (1995) · Vision Research · doi:10.1016/0042-6989(94)00180-t · Cited by 105 · cited 1×
“A number of studies have confirmed that aliasing can be seen while viewing conventional gratings (Smith & Cass, 1987; Anderson & Hess, 1990; Galvin & Williams, 1992; Artal et al., 1995).”
BackgroundOptical Image Quality and the Cone Mosaic
Snyder, A. W., Bossomaier, T. R. J., & Hughes, A. (1986) · Science · doi:10.1126/science.3941914 · Cited by 96 · cited 1×
“Snyder et al. (1986, 1990) argued that it is advantageous for optical quality to exceed the limits set by retinal sampling.”
BackgroundPost-receptoral undersampling in normal human peripheral vision
Anderson, S. J., & Hess, R. F. (1990) · Vision Research · doi:10.1016/0042-6989(90)90031-f · Cited by 83 · cited 1×
“A number of studies have confirmed that aliasing can be seen while viewing conventional gratings (Smith & Cass, 1987; Anderson & Hess, 1990; Galvin & Williams, 1992; Artal et al., 1995).”
BackgroundAliasing in the parafovea with incoherent light
Smith, R. A., & Cass, P. F. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001530 · Cited by 59 · cited 1×
“A number of studies have confirmed that aliasing can be seen while viewing conventional gratings (Smith & Cass, 1987; Anderson & Hess, 1990; Galvin & Williams, 1992; Artal et al., 1995).”
BackgroundSerial spatial filters in vision
Chen, B., Makous, W. L., & Williams, D. R. (1993) · Vision Research · doi:10.1016/0042-6989(93)90095-e · Cited by 54 · cited 2×
“The value of 0.48 was taken from psychophysical estimates of the cone aperture using a distortion product technique (MacLeod et al., 1992; Chen et al., 1993).”
BackgroundMethodSelf-citationCone mosaic observed directly through natural pupil of live vertebrate
Land, M. F., & Snyder, A. W. (1985) · Vision Research · doi:10.1016/0042-6989(85)90230-5 · Cited by 40
No aliasing at edges in normal viewing
Galvin, S. J., & Williams, D. R. (1992) · Vision Research · doi:10.1016/0042-6989(92)90089-2 · Cited by 36 · cited 1×
“A number of studies have confirmed that aliasing can be seen while viewing conventional gratings (Smith & Cass, 1987; Anderson & Hess, 1990; Galvin & Williams, 1992; Artal et al., 1995).”
BackgroundSelf-citationVisibility of photoreceptors in the intact living cane toad eye
Jagger, W. S. (1985) · Vision Research · doi:10.1016/0042-6989(85)90179-8 · Cited by 23 · cited 1×
“In several snake species as well as the cane toad, single photoreceptors were resolved through the intact optics by capitalizing on their large photoreceptors and good optics (Land & Snyder, 1985; Zwick et al., 1995; Jagger, 1985).”
Background
Cited by
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Self-citationAberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Self-citationIn Vivo Imaging of Human Cone Photoreceptor Inner Segments
Scoles, D., Sulai, Y. N., Langlo, C. S., Fishman, G. A., Curcio, C. A., Carroll, J., & Dubra, A. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14542 · Cited by 380
Adaptation of the central retina for high acuity vision: Cones, the fovea and the avascular zone
Provis, J. M., Dubis, A. M., Maddess, T., & Carroll, J. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.01.005 · Cited by 298
Adaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Metadata
- Authors
- Miller, D. T., Williams, D. R., Morris, G. M., & Liang, J.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1996-04
- Volume
- 36
- Issue
- 8
- Pages
- 1067-1079
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2158988853
- Cited by
- 184
- References
- 33
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.