Development of EMG-based mode and intent recognition algorithms for a computer-controlled above-knee prosthesis
The DOI matches its Crossref record.
Abstract
Conventional above-knee prostheses are unable to replace normal leg function due to the lack of adaptive control. Computer-controlled prostheses offer the possibility to implement such adaptive control. For a particular locomotion mode, control algorithms can generate appropriate damping profiles as a function of selected sensory inputs and stored information on normal walking. However, it is essential in such systems that the locomotor modes can be determined accurately from the inputs of the control system. Recognition of the intent to change from one mode to another is also a necessity because the control system has to account for such transitions. The possibility of using EMG signals from hip muscles and muscle residuals of the stump for this purpose is investigated. The modes tested are level walking, ramp ascent and ramp descent with slopes of 6 degrees and 9 degrees. EMG activity curves for three muscles: gluteus maximus, gluteus medius and tensor fasciae latae, are presented for the different modes. The results are obtained from two reference groups of 12 normal individuals and from a prosthetic patient. The results show the possibility of discriminating between modes. A discussion is made of the implementation of the results obtained by a finite state approach and the difficulties relating to the use of EMG signals for control purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“It is noteworthy that there are relatively few studies that document the implementation of a complete hierarchical, multifunctional control structure similar to the one suggested here and have demonstrated its use in a practical setting [24,67,114-119].”
A Strategy for Identifying Locomotion Modes Using Surface Electromyography
Huang, H., Kuiken, T. A., & Lipschutz, R. D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003293 · Cited by 512
User‐adaptive control of a magnetorheological prosthetic knee
Herr, H., & Wilkenfeld, A. (2003) · Industrial Robot: An International Journal · doi:10.1108/01439910310457706 · Cited by 293
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Metadata
- Authors
- Peeraer, L., Aeyels, B., & Van der Perre, G.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1990-05-01
- Volume
- 12
- Issue
- 3
- Pages
- 178-182
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W2002696260
- Cited by
- 87
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of EMG-based mode and intent recognition algorithms for a computer-controlled above-knee prosthesis. https://app.cochat.ai/papers/10.1016/0141-5425(90)90037-n
- The paper
- Peeraer, L., Aeyels, B., & Van der Perre, G. (1990). Development of EMG-based mode and intent recognition algorithms for a computer-controlled above-knee prosthesis. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(90)90037-n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.