Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 317

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Upper-Extremity Volume Measurements in Women With Lymphedema: A Comparison of Measurements Obtained Via Water Displacement With Geometrically Determined Volume

Sander, Antoinette P, Hajer, Nicole M, Hemenway, Kristie, Miller, Amy C·2002·Physical Therapy

Abstract

Background and Purpose. Upper-extremity (UE) swelling following breast cancer treatment is a frequent manifestation of lymphedema. In order to document outcomes from lymphedema treatments, reliable, valid, and practical measurements of UE swelling are necessary. The purpose of this study was to compare geometric methods of determining UE volumes with water displacement methods. Subjects. The edematous hand, forearm, and upper arm of 50 women with UE swelling secondary to lymphedema were measured. Methods. Upper-extremity volumes were determined by water displacement using arm and hand volumeters. Displaced water was weighed to determine volume. Circumferential girth measurements were taken. Width and depth measurements of the hand were taken with a tension-controlled caliper. Geometric volume formulas for a cylinder, frustum, rectangular solid, and trapezoidal solid were used to calculate volumes of the arm and hand at different measurement intervals. Results. Intraclass correlation coefficients [2,1] for interrater and intrarater reliability of all water and geometric measurements of the arm and hand were .91 to .99 and .92 to .99, respectively. Water displacement correlated with geometric measurements in the arm (r=.97–.98) and in the hand (r=.81–.91). The limits of agreement (LOA) indicated that water and geometric measurements of arm volume differed by 479 to 655 mL. Scatterplots of the LOA data indicated in that geometric volumes were either larger or smaller than water volumes. The smallest standard error of measurement for the arm measurements was for the 6-cm frustum method at 115 mL; for the hand measurements, the smallest standard error of measurement was for the frustum method at 16 mL. Discussion and Conclusion. Volume of an edematous UE calculated by geometric formulas correlated strongly with volume determined by water displacement. Although strongly correlated, the measurements obtained by the 2 methods did not agree.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ptj/82.12.1201

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 317

Metadata

Authors
Sander, A. P., Hajer, N. M., Hemenway, K., & Miller, A. C.
Venue
Physical Therapy
Published
2002-12-01
Volume
82
Issue
12
Pages
1201-1212
ISSN
  • 0031-9023 (ISSN-L)
  • 1538-6724
OpenAlex
W2110960601
Cited by
317
References
21
FWCI
1.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Upper-Extremity Volume Measurements in Women With Lymphedema: A Comparison of Measurements Obtained Via Water Displacement With Geometrically Determined Volume. https://app.cochat.ai/papers/10.1093/ptj/82.12.1201
The paper
Sander, A. P., Hajer, N. M., Hemenway, K., & Miller, A. C. (2002). Upper-Extremity Volume Measurements in Women With Lymphedema: A Comparison of Measurements Obtained Via Water Displacement With Geometrically Determined Volume. Physical Therapy. https://doi.org/10.1093/ptj/82.12.1201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.