Interfacial photopolymerization of poly(ethylene glycol)-based hydrogels upon alginate-poly(l-lysine) microcapsules for enhanced biocompatibility
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The biocompatibility of microcapsules made by the co-acervation of alginate and poly(l-lysine) (PLL) was enhanced by coating the surface of these microcapsules with a poly(ethylene glycol) (PEG)-based hydrogel. The hydrogel was formed by an interfacial photopolymerization technique using visible light from an argon ion laser. The light absorbing chromophore, eosin Y, was immobilized on the microcapsule surface. This restricted the formation of the PEG hydrogel to the surface of the microcapsule. The presence of the PEG gel on the surface was confirmed by fluorescent dextran entrapment, by direct visualization after dissolution of the underlying membrane and by electron spectroscopy for chemical analysis. The biological response of such microcapsules was evaluated by intraperitoneal implantation in mice. The PEG-coated microcapsules were found to be less inflammatory and were seen not to elicit a fibrotic response, as was the case with alginate-PLL microcapsules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Cited by
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Photopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
“Photopolymerized PEG diacrylate hydrogels have been explored for the transplantation of islets of Langerhans for development of a bioartificial endocrine pancreas [17,18,55].”
Background25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Polyethylene glycol (PEG): A versatile polymer for pharmaceutical applications
D’souza, A. A., & Shegokar, R. (2016) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1182485 · Cited by 1,282
“[65,66] The osmotic pressure and elastic restoring forces of PEG also adds on to the stealth mechanism.[67] Binding of PEG to any foreign substance results in lower interfacial free energy, high steric repulsion, and conformational loss in entropy of bound PEG.”
BackgroundFairbanks, B. D., Schwartz, M. P., Bowman, C. N., & Anseth, K. S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.08.055 · Cited by 1,200
Advances in crosslinking strategies of biomedical hydrogels
Hu, W., Wang, Z., Xiao, Y., Zhang, S., & Wang, J. (2019) · Biomaterials Science · doi:10.1039/c8bm01246f · Cited by 896
3D printing of hydrogels: Rational design strategies and emerging biomedical applications
Li, J., Wu, C., Chu, P. K., & Gelinsky, M. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2020.100543 · Cited by 862
The controlled intravenous delivery of drugs using PEG-coated sterically stabilized nanospheres
Gref, R., Domb, A., Quellec, P., Blunk, T., Müller, R. H., Verbavatz, J. M., & Langer, R. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00026-4 · Cited by 820
Review: Hydrogels for cell immobilization
Jen, A. C., Wake, M. C., & Mikos, A. G. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<357::aid-bit2>3.0.co;2-k · Cited by 484
Current trends in interfacial polymerization chemistry
Raaijmakers, M. J. T., & Benes, N. E. (2016) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.06.004 · Cited by 435
Advances in islet encapsulation technologies
Desai, T., & Shea, L. D. (2017) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.232 · Cited by 427
Elbert, D. L., & Hubbell, J. A. (2001) · Biomacromolecules · doi:10.1021/bm0056299 · Cited by 409
Self-citationPhotopolymerization of cell-encapsulating hydrogels: Crosslinking efficiency versus cytotoxicity
Mironi-Harpaz, I., Wang, D. Y., Venkatraman, S., & Seliktar, D. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.12.034 · Cited by 364
Micromolding of shape-controlled, harvestable cell-laden hydrogels
Yeh, J., Ling, Y., Karp, J. M., Gantz, J., Chandawarkar, A., Eng, G., Blumling III, J., Langer, R., & Khademhosseini, A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.005 · Cited by 339
Immunomodulatory Biomaterials for Tissue Repair
Whitaker, R., Hernaez-Estrada, B., Hernandez, R. M., Santos-Vizcaino, E., & Spiller, K. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00895 · Cited by 338
Polymers in cell encapsulation from an enveloped cell perspective
de Vos, P., Lazarjani, H. A., Poncelet, D., & Faas, M. M. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.005 · Cited by 298
“The decrease in protein adsorption is attributable to the osmotic pressure and elastic restoring forces generated by the PEG chains that are not compatible with interactions with protein molecules [245].”
Water-Soluble Photoinitiators in Biomedical Applications
Tomal, W., & Ortyl, J. (2020) · Polymers · doi:10.3390/polym12051073 · Cited by 250
Thiol–norbornene photoclick hydrogels for tissue engineering applications
Lin, C., Ki, C. S., & Shih, H. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41563 · Cited by 236
Synthesis and characterization of a novel degradable phosphate-containing hydrogel
Wang, D. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00280-1 · Cited by 231
Hydrogels used for cell‐based drug delivery
Schmidt, J. J., Rowley, J., & Kong, H. J. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32287 · Cited by 228
Multiscale requirements for bioencapsulation in medicine and biotechnology
de Vos, P., Bučko, M., Gemeiner, P., Navrátil, M., Švitel, J., Faas, M., Strand, B. L., Skjak-Braek, G., Morch, Y. A., Vikartovská, A., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.014 · Cited by 212
Visible‐Light‐Mediated Thiol‐Ene Hydrogelation Using Eosin‐Y as the Only Photoinitiator
Shih, H., & Lin, C. (2013) · Macromolecular Rapid Communications · doi:10.1002/marc.201200605 · Cited by 209
Metadata
- Authors
- Sawhney, A. S., Pathak, C. P., & Hubbell, J. A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1993-10
- Volume
- 14
- Issue
- 13
- Pages
- 1008-1016
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2017823446
- Cited by
- 148
- References
- 2
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.