Fractured polymer/silica fiber surface studied by tapping mode atomic force microscopy
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Scanning Tunneling Microscopy and Atomic Force Microscopy: Application to Biology and Technology
Hansma, P. K., Elings, V. B., Marti, O., & Bracker, C. E. (1988) · Science · doi:10.1126/science.3051380 · Cited by 716
Self-citationRugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Friction and wear of Langmuir-Blodgett films observed by friction force microscopy
Meyer, E., Overney, R., Brodbeck, D., Howald, L., Lüthi, R., Frommer, J., & Güntherodt, H.-J. (1992) · Physical Review Letters · doi:10.1103/physrevlett.69.1777 · Cited by 272
Cited by
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Environmental instability of few-layer black phosphorus
Island, J. O., Steele, G. A., Zant, H. S. J. V. D., & Castellanos-Gomez, A. (2015) · 2D Materials · doi:10.1088/2053-1583/2/1/011002 · Cited by 954
Influence of cholesterol on liposome stability and on in vitro drug release
Briuglia, M.-L., Rotella, C., McFarlane, A., & Lamprou, D. A. (2015) · Drug Delivery and Translational Research · doi:10.1007/s13346-015-0220-8 · Cited by 740
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Self-citationAn atomic force microscope tip designed to measure time-varying nanomechanical forces
Sahin, O., Magonov, S., Su, C., Quate, C. F., & Solgaard, O. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.226 · Cited by 481
CHARACTERIZATION OF POLYMER SURFACES WITH ATOMIC FORCE MICROSCOPY
Magonov, S. N., & Reneker, D. H. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.175 · Cited by 444
Age-related vascular stiffening: causes and consequences
Kohn, J. C., Lampi, M. C., & Reinhart-King, C. A. (2015) · Frontiers in Genetics · doi:10.3389/fgene.2015.00112 · Cited by 440
“The two primary AFM modes are ‘contact mode,’ where the cantilever tip is dragged along the sample surface, or ‘AC (tapping)’ mode, where the tip oscillates near its resonant frequency close to the sample surface and intermittent indentations are recorded (Zhong et al., 1993).”
BackgroundImaging and manipulation of biological structures with the AFM
Fotiadis, D. (2002) · Micron · doi:10.1016/s0968-4328(01)00026-9 · Cited by 390
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Single molecule force spectroscopy in biology using the atomic force microscope
Zlatanova, J., Lindsay, S. M., & Leuba, S. H. (2000) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(00)00014-6 · Cited by 375
Bitumen morphologies by phase‐detection atomic force microscopy
MASSON, J., LEBLOND, V., & MARGESON, J. (2006) · Journal of Microscopy · doi:10.1111/j.1365-2818.2006.01540.x · Cited by 357
High-speed atomic force microscopy coming of age
Ando, T. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/6/062001 · Cited by 355
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Yaneva, M. (1997) · The EMBO Journal · doi:10.1093/emboj/16.16.5098 · Cited by 324
High-Speed AFM and Applications to Biomolecular Systems
Ando, T., Uchihashi, T., & Kodera, N. (2013) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-083012-130324 · Cited by 301
Tapping-Mode Atomic Force Microscopy Produces Faithful High-Resolution Images of Protein Surfaces
Möller, C., Allen, M., Elings, V., Engel, A., & Müller, D. J. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76966-3 · Cited by 274
Self-citationBurnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D. (1997) · Nanotechnology · doi:10.1088/0957-4484/8/2/004 · Cited by 265
High-speed AFM and nano-visualization of biomolecular processes
Ando, T., Uchihashi, T., Kodera, N., Yamamoto, D., Miyagi, A., Taniguchi, M., & Yamashita, H. (2008) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0406-0 · Cited by 262
Applications for atomic force microscopy of DNA
Hansma, H. G., Laney, D. E., Bezanilla, M., Sinsheimer, R. L., & Hansma, P. K. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80343-7 · Cited by 248
Probing Soft Matter with the Atomic Force Microscopies: Imaging and Force Spectroscopy
McConney, M. E., Singamaneni, S., & Tsukruk, V. V. (2010) · Polymer Reviews · doi:10.1080/15583724.2010.493255 · Cited by 241
“19 , 20 Generally, noncontact modes operate with the probe scanning about 5–40 nm above the sample surface, perturbed by the attractive van der Waals forces between the tip and the sample; see Figure 1B .”
BackgroundA Tutorial on the Mechanisms, Dynamics, and Control of Atomic Force Microscopes
Abramovitch, D. Y., Andersson, S. B., Pao, L. Y., & Schitter, G. (2007) · 2007 American Control Conference · doi:10.1109/acc.2007.4282300 · Cited by 226
“In the most common form of dynamic mode, also known as AC mode, intermittent contact mode, or by the trademarked name “tapping mode” [94], [95], the amplitude of the free oscillation is slightly larger than the nominal tip/surface distance.”
BackgroundAFM, ESEM, TEM, and CLSM in liposomal characterization: a comparative study
Ruozi, B., Belletti, D., Tombesi, A., Tosi, G., Bondioli, L., Forni, F., & Vandelli, M. A. (2011) · International Journal of Nanomedicine · doi:10.2147/ijn.s14615 · Cited by 225
HANLEY, S. J., REVOL, J.-F., GODBOUT, L., & GRAY, D. G. (1997) · Cellulose · doi:10.1023/a:1018483722417 · Cited by 209
“The lateral resolution is limited by the tip radius and not by the height of the tip above the sample, as in noncontact methods ( Zhong et al., 1993 ).”
BackgroundMethodSimultaneous Height and Adhesion Imaging of Antibody-Antigen Interactions by Atomic Force Microscopy
Willemsen, O. H., Snel, M. M. E., van der Werf, K. O., de Grooth, B. G., Greve, J., Hinterdorfer, P., Gruber, H. J., Schindler, H., van Kooyk, Y., & Figdor, C. G. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77666-0 · Cited by 204
“Tapping mode (Zhong et al., 1993; Hansma et al., 1994; Putman et al., 1994) was used for high-resolution imaging the topography of proteins in buffer.”
MethodAtomic force microscopy and spectroscopy
Seo, Y., & Jhe, W. (2008) · Reports on Progress in Physics · doi:10.1088/0034-4885/71/1/016101 · Cited by 193
Past, present and future of atomic force microscopy in life sciences and medicine
Parot, P., Dufrêne, Y. F., Hinterdorfer, P., Le Grimellec, C., Navajas, D., Pellequer, J., & Scheuring, S. (2007) · Journal of Molecular Recognition · doi:10.1002/jmr.857 · Cited by 189
“AFM in biology was transformed with the introduction of a vibrating mode in air (Zhong et al., 1993), then in liquid with the so-called tapping mode described in two papers published in the same journal, one in March (Hansma et al., 1994) and the other in May (Putman et al., 1994).”
MethodFrom Images to Interactions: High-Resolution Phase Imaging in Tapping-Mode Atomic Force Microscopy
Stark, M., Möller, C., Müller, D. J., & Guckenberger, R. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76266-2 · Cited by 185
“In tapping-mode (TM)-AFM (Zhong et al., 1993; Putman et al., 1994; Hansma et al., 1994), the cantilever is excited to oscillate close to its resonant frequency.”
BackgroundGlyphosate-induced stiffening of HaCaT keratinocytes, a Peak Force Tapping study on living cells
Heu, C., Berquand, A., Elie-Caille, C., & Nicod, L. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.02.007 · Cited by 160
Tissue section AFM: In situ ultrastructural imaging of native biomolecules
Graham, H. K., Hodson, N. W., Hoyland, J. A., Millward-Sadler, S. J., Garrod, D., Scothern, A., Griffiths, C. E. M., Watson, R. E. B., Cox, T. R., Erler, J. T., et al. (2010) · Matrix Biology · doi:10.1016/j.matbio.2010.01.008 · Cited by 116
“Operating the AFM in intermittent contact mode (also known as amplitude modulation or tapping mode) both reduces lateral forces on the sample (Zhong et al., 1993) and facilitates”
BackgroundPreparation of DNA and nucleoprotein samples for AFM imaging
Lyubchenko, Y. L. (2011) · Micron · doi:10.1016/j.micron.2010.08.011 · Cited by 93
“Initially, this mode was termed Tapping mode (Zhong et al., 1993), but the name has been trademarked by the AFM manufacturer Veeco.”
BackgroundMethodSpecific and non-specific phagocytosis of ligand-grafted PLGA microspheres by macrophages
Brandhonneur, N., Chevanne, F., Vié, V., Frisch, B., Primault, R., Le Potier, M.-F., & Le Corre, P. (2009) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.11.013 · Cited by 75
Metadata
- Authors
- Zhong, Q., Inniss, D., Kjoller, K., & Elings, V. B.
- Venue
- Surface Science Letters
- Publisher
- Elsevier BV
- Published
- 1993-06
- Volume
- 290
- Issue
- 1-2
- Pages
- L688-L692
- ISSN
- 0167-2584 (ISSN-L)
- OpenAlex
- W1964498537
- Cited by
- 628
- References
- 4
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.