A gait analysis data collection and reduction technique
The DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Greenwood, D. T. (1965) · Medical Entomology and Zoology · Cited by 660
Justification of triaxial goniometer for the measurement of joint rotation
Chao, E. Y. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90044-5 · Cited by 355
The anthropometry of the manual work space for the seated subject
Dempster, W. T., Gabel, W. C., & Felts, W. J. L. (1959) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330170405 · Cited by 253
Walking patterns of men with parkinsonism.
Mp, M., Sb, S., Gm, G., & Wj, D. (1978) · PubMed · Cited by 199
Anatomic Guide for the Electromyographer
Tichauer, E. R. (1977) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-197712000-00042 · Cited by 193
Pre- and Postoperative Gait Analysis in Patients with Spastic Diplegia: A Preliminary Report
Gage, J. R., Fabian, D., Hicks, R. R., & Tashman, S. (1984) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-198411000-00012 · Cited by 120
Self-citationMeasurement of Gait Movements from Motion Picture Film
SUTHERLAND, D. H., & HAGY, J. L. (1972) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197254040-00009 · Cited by 105
Comment on criteria for patient evaluation tools
Brand, R. A., & Crowninshield, R. D. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90093-2 · Cited by 70
Gait analysis for decision-making in cerebral palsy.
Gage, J. R. (1983) · PubMed · Cited by 60
Self-citation
Cited by
Items 101–200 of 1,006
Joint kinematic calculation based on clinical direct kinematic versus inverse kinematic gait models
Kainz, H., Modenese, L., Lloyd, D. G., Maine, S., Walsh, H. P. J., & Carty, C. P. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.03.052 · Cited by 173
“2.4.4 Plug-in-Gait models 1) Conventional PiG-DK model was the Vicon PiG model (Davis et al., 1991; Kadaba et al., 1990) (see supplementary online appendix A1 for PiG joint definitions).”
MethodInfluentialPelvic and lower limb compensatory actions of subjects in an early stage of hip osteoarthritis
Watelain, E., Dujardin, F., Babier, F., Dubois, D., & Allard, P. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.26812 · Cited by 172
On the expression of joint moments during gait
Schache, A. G., & Baker, R. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.018 · Cited by 171
“[23] were first measured.”
3D Tracking of Human Motion Using Visual Skeletonization and Stereoscopic Vision
Zago, M., Luzzago, M., Marangoni, T., Cecco, M. D., Tarabini, M., & Galli, M. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00181 · Cited by 171
“This marker set was adapted from standard protocols used in clinical gait analysis (Davis et al., 1991; Zago et al., 2017), and was designed to match the skeletal configuration of OpenPose ( Figure 2 ).”
MethodHart, J. M., Ko, J.-W. K., Konold, T. R., & Pietrosimione, B. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.12.004 · Cited by 169
“…et al., 2003) The concept of altered gait patterns following major knee injury has evolved with developing 3-dimensional video analysis technology which uses ground reaction force data during gait to estimate moments and torques at the knee joint during activities (Davis et al., 1991; Davis, 1997).”
BackgroundInfluentialEffect of obesity and low back pain on spinal mobility: a cross sectional study in women
Vismara, L., Menegoni, F., Zaina, F., Galli, M., Négrini, S., & Capodaglio, P. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-3 · Cited by 168
“The clinical usefulness of an optoelectronic approach is already widely acknowledged in gait analysis for the rehabilitation of several neurological and orthopaedic conditions [50].”
BackgroundHicks, J. L., Schwartz, M. H., Arnold, A. S., & Delp, S. L. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.01.002 · Cited by 167
“A standard clinical protocol was used to place and track the 3D motion of markers on the lower extremity (Davis et al., 1991) and calculate joint angles (Kadaba et al.”
MethodThe Effect of Running Shoes on Lower Extremity Joint Torques
Kerrigan, D. C., Franz, J. R., Keenan, G. S., Dicharry, J. M., Croce, U. D., & Wilder, R. P. (2009) · PM&R · doi:10.1016/j.pmrj.2009.09.011 · Cited by 171
“Sixteen retroreflective markers were placed over the following anatomical landmarks of the pelvis and lower extremity: bilateral anterior and posterior superior iliac spines, lateral midthighs, lateral femoral condyles, lateral midshanks, lateral malleoli, second metatarsal heads, and heels [24].”
BackgroundEffect of ankle-foot orthoses on walking efficiency and gait in children with cerebral palsy
Brehm, M., Harlaar, J., & Schwartz, M. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0209 · Cited by 165
Vertical and Horizontal Hop Performance: Contributions of the Hip, Knee, and Ankle
Kotsifaki, A., Korakakis, V., Graham-Smith, P., Sideris, V., & Whiteley, R. (2021) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738120976363 · Cited by 164
“In total, 42 reflective markers were placed according to a full-body Plug-in-Gait marker-set, extended with additional anatomical markers on the sacrum and the medial malleoli and 3 marker clusters laterally on each thigh and shank.(8) The motion data acquired from the participant were static anatomical poses and dyna…”
MethodPostural Control During Sit-to Stand and Gait in Stroke Patients
Chou, S., Wong, M., Leong, C., Hong, W.-S., Tang, F., & Lin, T.-H. (2003) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200301000-00007 · Cited by 163
Markerless vs. Marker-Based Gait Analysis: A Proof of Concept Study
Moro, M., Marchesi, G., Hesse, F., Odone, F., & Casadio, M. (2022) · Sensors · doi:10.3390/s22052011 · Cited by 163
“With the motion capture system, we acquired the 3D position of 22 infrared passive markers placed on the body of the participants following the Davis protocol [30].”
MethodGait patterns after anterior cruciate ligament reconstruction
Bulgheroni, P., Bulgheroni, M. V., Andrini, L., Guffanti, P., & Giughello, A. (1997) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050018 · Cited by 162
Chen, C.-L., Chen, H.-C., Tang, S. F.-T., Wu, C.-Y., Cheng, P.-T., & Hong, W.-H. (2003) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000098040.13355.b5 · Cited by 162
Kinematic description of elite vs. Low level players in team-handball jump throw.
Wagner, H., Buchecker, M., von DUVILLARD, S. P., & Müller, E. A. (2010) · Europe PMC (PubMed Central) · Cited by 162
Gait analysis – Available platforms for outcome assessment
Klöpfer-Krämer, I. T., Brand, A., Wackerle, H., Müßig, J. A., Kröger, I., & Augat, P. (2019) · Injury · doi:10.1016/j.injury.2019.11.011 · Cited by 165
DeLuca, P. A., Õunpuu, S., Davis, R. B., & Walsh, J. (1998) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199811000-00004 · Cited by 165
Self-citationThe influence of patella alta on patellofemoral joint stress during normal and fast walking
Ward, S. R., & Powers, C. M. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.07.009 · Cited by 161
“7, Oxford Metrics Ltd, Oxford, UK) (Davis et al., 1990).”
MethodThe coordinated movement of the lumbo–pelvic–hip complex during running: a literature review
Schache, A. G., Bennell, K. L., BLANCH, P. D., & Wrigley, T. V. (1999) · Gait & Posture · doi:10.1016/s0966-6362(99)00025-9 · Cited by 165
“[52,53], Cappozzo [54,55] and Kadaba et al.”
Representation and calculation of 3-D joint movement
Woltring, H. J. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90048-3 · Cited by 161
Baker, R. (2001) · Gait & Posture · doi:10.1016/s0966-6362(00)00083-7 · Cited by 160
“[2] independently suggested that joint angles in gait analysis should be represented as Cardan angles.”
BackgroundGeorgoulis, A. D., Moraiti, C., Ristanis, S., & Stergiou, N. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-1032-7 · Cited by 160
“; Englewood; CO) captured the movements of fifteen reflective markers placed on selected bony landmarks of the lower limbs and the pelvis using the model described by Davis [29].”
MethodInfluentialSagittal plane characterization of normal human ankle function across a range of walking gait speeds
Palmer, M. L. (2002) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 160
Simic, M., Wrigley, T. V., Hinman, R. S., Hunt, M. A., & Bennell, K. L. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.06.001 · Cited by 159
Näf, M. B., Junius, K., Rossini, M., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4042523 · Cited by 158
Stepping strategies used by post-stroke individuals to maintain margins of stability during walking
Hak, L., Houdijk, H., van der Wurff, P., Prins, M. R., Mert, A., Beek, P. J., & van Dieën, J. H. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.10.010 · Cited by 158
“Twelve high resolution infra-red cameras (Vicon, Oxford, UK) were used to capture kinematic data of 16 reflective markers attached to pelvis and the lower extremities (lower body plug-in-gait (Davis et al., 1991; Kadaba et al., 1990)).”
MethodProgressive resistance training improves gait initiation in individuals with Parkinson's disease
Hass, C. J., Buckley, T. A., Pitsikoulis, C., & Barthélemy, E. J. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.12.022 · Cited by 162
“Thirty-nine retroflective markers were placed over bony landmarks according to the modified Helen Hayes marker system [16].”
MethodFunctionally oriented and clinically feasible quantitative gait analysis method
Frigo, C., Rabuffetti, M., Kerrigan, D. C., Deming, L. C., & Pedotti, A. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510740 · Cited by 162
Krosshaug, T., & Bahr, R. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.04.033 · Cited by 157
“The joint centers of the ankle and knee were determined by the method of Davis et al. (1991) but the ankle joint center location was defined 1 cm distal to the lateral malleolus, as proposed by Eng and Winter (1995).”
MethodThe effect of the walking speed on the stability of the anterior cruciate ligament deficient knee
Stergiou, N., Moraiti, C., Giakas, G., Ristanis, S., & Georgoulis, A. D. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.06.008 · Cited by 157
“Using anthropometric measurements and the position of the reflective markers, we calculated three-dimensional knee joint angular displacement, using the algorithms described by Davis et al. (Davis et al., 1991).”
BackgroundMethodInfluentialZelik, K. E., Takahashi, K. Z., & Sawicki, G. S. (2015) · Journal of Experimental Biology · doi:10.1242/jeb.115451 · Cited by 156
“Joint centers of rotation were estimated based on regression from anatomical landmarks: the ankle from medial and lateral malleoli, the knee from medial and lateral femoral epicondyles, and the hip from the Helen Hayes pelvic marker set (Davis et al., 1991).”
MethodDeterminants of countermovement jump performance: a kinetic and kinematic analysis
McErlain‐Naylor, S. A., King, M. A., & Pain, M. T. G. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.924055 · Cited by 154
Automatic real-time gait event detection in children using deep neural networks
Kidziński, Ł., Delp, S., & Schwartz, M. (2019) · PLOS ONE · doi:10.1371/journal.pone.0211466 · Cited by 122
Goldberg, S. R., Õunpuu, S., Arnold, A. S., Gage, J. R., & Delp, S. L. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.01.015 · Cited by 153
“Motion data were collected using a multiple-camera motion measurement system, and each subject's gait kinematics and kinetics were computed using methods described by Davis et al. (1991).”
MethodSelf-citationBias compensated least squares estimate of the center of rotation
Halvorsen, K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00070-8 · Cited by 152
Schache, A. G., Baker, R. J., & Lamoreux, L. W. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2005.08.002 · Cited by 151
“By reanalysing gait data for a small cohort that was collected using a protocol similar to the Helen Hayes model [5,22], the technique substantially reduced knee joint angle cross-talk.”
MethodGait pattern in Duchenne muscular dystrophy
D’Angelo, M. G., Berti, M., Piccinini, L., Romei, M., Guglieri, M., Bonato, S., Degrate, A., Turconi, A. C., & Bresolin, N. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.06.002 · Cited by 151
“Markers (spherical retroflective markers: 15 mm in diameter) were positioned according to Davis’ protocol [27].”
MethodAn ecologically-controlled exoskeleton can improve balance recovery after slippage
Monaco, V., Tropea, P., Aprigliano, F., Martelli, D., Parri, A., Cortese, M. D., Molino-Lova, R., Vitiello, N., & Micera, S. (2017) · Scientific Reports · doi:10.1038/srep46721 · Cited by 150
Galli, M., Cimolin, V., Crivellini, M., & Campanini, I. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.003 · Cited by 149
Arnold, A. S., Blemker, S. S., & Delp, S. L. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1355277 · Cited by 149
Locomotor patterns in cerebellar ataxia
Martino, G., Ivanenko, Y. P., Serrao, M., Ranavolo, A., d’Avella, A., Draicchio, F., Conte, C., Casali, C., & Lacquaniti, F. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00275.2014 · Cited by 149
The up and down bobbing of human walking: a compromise between muscle work and efficiency
Massaad, F., Lejeune, T. M., & Detrembleur, C. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.127969 · Cited by 149
Santilli, V., Frascarelli, M., Paoloni, M., Frascarelli, F., Camerota, F., Natale, L. D., & Santis, F. D. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504274147 · Cited by 147
“Retroreflective markers, 15 mm in diameter, were pasted onto the skin according to the protocol of Davis et al.4 Kinetic and kinematic data were obtained using 8 infrared cameras recording 2-dimensional coordinates of the markers at 100 Hz.”
MethodMoment-angle relationship at lower limb joints during human walking at different velocities
Frigo, C., Crenna, P., & Jensen, L. (1996) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(96)00030-2 · Cited by 146
Gait Patterns after Anterior Cruciate Ligament Reconstruction are Related to Graft Type
Webster, K. E., Wittwer, J. E., O'Brien, J., & Feller, J. A. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546504266483 · Cited by 145
“Fifteen reflective markers were then attached to the anterior superior iliac spine, sacrum, lateral aspects of the thigh and leg, knee joint axis, lateral malleolus, heel, and forefoot of each subject.(7,18) The thigh and leg markers were attached to 6-cmlong wands and secured in place with Micropore tape (3M, Maplewo…”
MethodBoyd, R. N., Pliatsios, V., Starr, R., Wolfe, R. S., & Graham, H. K. (2000) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2000.tb00022.x · Cited by 145
Movement variability and skill level of various throwing techniques
Wagner, H., Pfusterschmied, J., Klous, M., von DUVILLARD, S. P., & Müller, E. A. (2011) · Human Movement Science · doi:10.1016/j.humov.2011.05.005 · Cited by 144
Kawamura, C. M., Filho, M. C. D. M., Barreto, M. M., de Paula, S. K., Juliano, Y., & Novo, N. F. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.005 · Cited by 144
“All data were analyzed using the models implemented in the Vicon Clinical Manager; employing the Helen Hayes marker set with an estimation of joint centers based on Davis’ anthropometric model [11].”
MethodNobile, M., Perego, P., Piccinini, L., Mani, E., Rossi, A., Bellina, M., & Molteni, M. (2011) · Autism · doi:10.1177/1362361309356929 · Cited by 129
“After collecting some anthropometric information (knee and ankle diameter, body height, body weight, height of the pelvis and distance between the anterior iliac spines), a rigid frame was computed for each sample frame starting from raw data (Davis et al., 1991).”
MethodMiki, H., Sugano, N., Hagio, K., Nishii, T., Kawakami, H., Kakimoto, A., Nakamura, N., & Yoshikawa, H. (2003) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.009 · Cited by 144
“A special vector in the pelvic coordinate system was set to define the hip joint center using pelvic size and leg length as scaling factors (Davis et al., 1991).”
MethodArnold, A. S., & Delp, S. L. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00232-3 · Cited by 144
“We tested this hypothesis using a musculoskeletal model with a ‘‘deformable’’ femur that estimates the muscle moment arms at the body positions of patients who walk with crouched, internally rotated gait.”
MethodMcClelland, J. A., Webster, K. E., Feller, J. A., & Menz, H. B. (2010) · The Knee · doi:10.1016/j.knee.2010.04.005 · Cited by 143
“Joint kinematics were calculated using Euler angles where the movement of the distal segment was related to the fixed proximal segment [26,27].”
BackgroundMethodGraf, A. N., Judge, J. O., Õunpuu, S., & Thelen, D. G. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.06.007 · Cited by 145
Self-citationHow much muscle strength is required to walk in a crouch gait?
Steele, K. M., van der Krogt, M. M., Schwartz, M. H., & Delp, S. L. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.07.028 · Cited by 145
“Three-dimensional motion analysis data was collected using a 12-camera system (Vicon Motion Systems, Lake Forest, CA) and a standard marker measurement protocol (Davis et al., 1991).”
Meldrum, D., Shouldice, C., Conroy, R. M., Jones, K., & Forward, M. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.07.130 · Cited by 142
“Reflective markers (n = 15) were placed on the lower limbs according to the Modified Helen Hayes Model [15].”
MethodSquatting Exercises in Older Adults: Kinematic and Kinetic Comparisons
Flanagan, S. P., Salem, G. J., Wang, M., Sanker, S., & Greendale, G. A. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000058364.47973.06 · Cited by 141
Biomechanical assessment of dynamic balance: Specificity of different balance tests
Ringhof, S., & Stein, T. (2018) · Human Movement Science · doi:10.1016/j.humov.2018.02.004 · Cited by 146
Gait Pattern in Inherited Cerebellar Ataxias
Serrao, M., Pierelli, F., Ranavolo, A., Draicchio, F., Conte, C., Don, R., Fabio, R. D., Lerose, M., Padua, L., Sandrini, G., et al. (2011) · The Cerebellum · doi:10.1007/s12311-011-0296-8 · Cited by 140
“landmarks in accordance with validated biomechanical models [21, 22].”
MethodFoot contact event detection using kinematic data in cerebral palsy children and normal adults gait
Desailly, É., Yepremian, D., Sardain, P., & Lacouture, P. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.06.009 · Cited by 140
“A set of classical clinical-purpose Helen Hayes markers was used to collect kinematic data [7].”
MethodChouliaras, V., Ristanis, S., Moraiti, C., Stergiou, N., & Georgoulis, A. D. (2007) · The American Journal of Sports Medicine · doi:10.1177/03635465062960411 · Cited by 140
Yeung, L.-F., Yang, Z.-Q., Cheng, K. C., Du, D., & Tong, R. K. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.04.005 · Cited by 139
Amano, S., Nocera, J. R., Vallabhajosula, S., Juncos, J. L., Gregor, R. J., Waddell, D. E., Wolf, S. L., & Hass, C. J. (2013) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2013.06.007 · Cited by 125
“Prior to the evaluation, participants were fitted with retroreflective markers according to a modified Helen Hayes marker set [26].”
Method12 Retrieving Information from Human Movement Patterns
Troje, N. F. (2008) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195188370.003.0014 · Cited by 143
Weidow, J., Tranberg, R., Saari, T., & Kärrholm, J. (2006) · Journal of Orthopaedic Research® · doi:10.1002/jor.20194 · Cited by 138
Stansfield, B. W., Hillman, S. J., Hazlewood, M. E., Lawson, A. M., Mann, A. M., Loudon, I. R., & Robb, J. (2001) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200105000-00027 · Cited by 144
Marí, S. M., Serrao, M., Casali, C., Conte, C., Martino, G., Ranavolo, A., Coppola, G., Draicchio, F., Padua, L., Sandrini, G., et al. (2013) · The Cerebellum · doi:10.1007/s12311-013-0533-4 · Cited by 136
“[22].”
ACL deficiency affects stride‐to‐stride variability as measured using nonlinear methodology
Moraiti, C., Stergiou, N., Ristanis, S., & Georgoulis, A. D. (2007) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-007-0373-1 · Cited by 136
“A six-camera optoelectronic system (Peak Motus 4.33; Peak Performance Technologies, Inc., Englewood, CO, USA) was used to capture the threedimensional movements of 15 reflective markers placed on the selected bony landmarks of the lower limbs and the pelvis using the model described by Davis [11].”
BackgroundMethodInfluentialBenedetti, M. G., Beghi, E., TANTI, A. D., Cappozzo, A., Basaglia, N., Cutti, A. G., Cereatti, A., Stagni, R., Verdini, F., Manca, M., et al. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.08.003 · Cited by 136
Ergonomic Evaluation of Biomechanical Hand Function
Lee, K.-S., & Jung, M. (2014) · Safety and Health at Work · doi:10.1016/j.shaw.2014.09.002 · Cited by 134
Lenaerts, G., Bartels, W., Gelaude, F., Mulier, M., Spaepen, A. J., der Perre, G. V., & Jonkers, I. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.03.037 · Cited by 133
“A full body marker protocol including 30 markers was used (Davis et al., 1991), adding 4 extra markers on the medial epicondyles and malleoli during the static pose only (Fig.”
MethodStief, F., Böhm, H., Michel, K., Schwirtz, A., & Döderlein, L. (2013) · Journal of Applied Biomechanics · doi:10.1123/jab.29.1.105 · Cited by 135
“A single comprehensive marker set was defined allowing the use of exactly the same gait cycles for the PiG protocol (Davis et al., 1991) without the Knee Alignment Device method (Davis & DeLuca, 1996) and the MA.”
MethodA 3D Generic Inverse Dynamic Method using Wrench Notation and Quaternion Algebra
Dumas, R., Aïssaoui, R., & de Guise, J. A. (2004) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840410001727805 · Cited by 133
“The Euler/Cardanic angles are sequencedependent and vary for different joints [2,7,10,11,13,14].”
BackgroundA comparison of kinetic gait parameters for 3–13 year olds
Chester, V. L., Tingley, M. A., & Biden, E. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.02.007 · Cited by 141
The importance of swing-phase initial conditions in stiff-knee gait
Goldberg, S. R., Õunpuu, S., & Delp, S. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00106-4 · Cited by 133
“Motion data were collected using a three-camera motion measurement system as described by Davis et al. (1991), and each subject’s threedimensional gait kinematics were computed using methods described by Kadaba et al. (1990).”
MethodSelf-citationFemoral derotation osteotomy in spastic diplegia: PROXIMAL OR DISTAL?
Pirpiris, M., Trivett, A., Baker, R. J., Rodda, J., Nattrass, G. R., & Graham, H. K. (2003) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.85b2.13342 · Cited by 131
A force measuring treadmill in clinical gait analysis
Dierick, F., Penta, M., Renaut, D., & Detrembleur, C. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2003.11.001 · Cited by 130
“The net sagittal ankle joint moment was computed by using a 3D inverse dynamics approach[13].”
MethodGait patterns in children with autism
Calhoun, M., Longworth, M., & Chester, V. L. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.09.013 · Cited by 129
Statistical method for prediction of gait kinematics with Gaussian process regression
Yun, Y., Kim, H.-C., Shin, S. Y., Lee, J.-W., Deshpande, A. D., & Kim, C.-H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.032 · Cited by 131
“Over the last two decades, the introduction of motion capture devices in gait pattern research has led to the collection of a large amount of data (Kadaba et al., 1990; Davis et al., 1991).”
BackgroundOrishimo, K. F., Liederbach, M., Kremenic, I. J., Hagins, M., & Pappas, E. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546514523928 · Cited by 128
“Two additional markers were placed on the sacrum and the left posterior superior iliac spine as per the Helen Hayes system.(4) Marker positions were collected at 250 Hz using 8 Eagle cameras (Motion Analysis Corp, Santa Rosa, California, USA).”
Method3D joint dynamics of walking in toddlers
Hallemans, A., Clercq, D. D., Otten, B., & Aerts, P. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.07.010 · Cited by 130
“An adjusted version of the Helen–Hayes marker set-up [27] (Fig.”
MethodHorsak, B., Eichmann, A., Lauer-Maier, K., Prock, K., Krondorfer, P., Siragy, T., & Dumphart, B. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111801 · Cited by 128
Grecco, L. A. C., Duarte, N. D. A. C., de Mendonça, M. E., Cimolin, V., Galli, M., Fregni, F., & Oliveira, C. S. (2014) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2014.07.030 · Cited by 128
A new approach to determine the hip rotation profile from clinical gait analysis data
Baker, R. J., Finney, L., & Orr, J. (1999) · Human Movement Science · doi:10.1016/s0167-9457(99)00027-5 · Cited by 127
Don, R., Serrao, M., Vinci, P., Ranavolo, A., Cacchio, A., Ioppolo, F., Paoloni, M., Procaccianti, R., Frascarelli, F., Santis, F. D., et al. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.06.002 · Cited by 127
“Anthropometric data were collected for each subject and retroreflective spherical markers placed over prominent bony landmarks (Davis et al., 1991).”
MethodBiomechanics of the natural, arthritic, and replaced human ankle joint
Leardini, A., O'Connor, J. J., & Giannini, S. (2014) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-7-8 · Cited by 127
Rossom, S. V., Smith, C. R., Thelen, D. G., Vanwanseele, B., Assche, D. V., & Jonkers, I. (2018) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2018.7459 · Cited by 126
Neural Control of Balance During Walking
Reimann, H., Fettrow, T., Thompson, E. D., & Jeka, J. J. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01271 · Cited by 130
“Reflective markers were placed bilaterally on the feet, lower legs, thighs, pelvis, torso, head, upper arms, forearms, and hands of the subject, using the Plug-in Gait marker set (Davis et al., 1991) with six additional markers on the anterior thigh, anterior tibia, and 5th metatarsal of each foot for a total of 45 ma…”
OPTIMIZATION OF WALKING ABILITY OF CHILDREN WITH CEREBRAL PALSY
Davids, J. R., Õunpuu, S., DeLuca, P. A., & Davis, R. B. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200311000-00028 · Cited by 126
Self-citationZhang, L., Li, Z., Hu, Y., Smith, C., Gutierrez-Farewik, E. M., & Wang, R. (2020) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3033664 · Cited by 124
“Sweden) was used to record the trajectories of the markers placed on the subjects according to a conventional marker set (Plug-in Gait/CGM1) protocol [28], [29].”
MethodFrank, B. S., Bell, D. R., Norcross, M. F., Blackburn, J. T., Goerger, B. M., & Padua, D. A. (2013) · The American Journal of Sports Medicine · doi:10.1177/0363546513496625 · Cited by 126
“An inverse dynamics approach was carried out to calculate internal net joint moments during the SSCT.(9) Internal moments represent the body’s resistance to external moments generated by the GRF and inertial force acting about a joint.”
MethodResultInfluentialBarton, C. J., Levinger, P., Crossley, K. M., Webster, K. E., & Menz, H. B. (2012) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2012.02.007 · Cited by 123
“, 2001) and conventional lower limb kinematic model (Vicon Plug-in Gait — PIG) (Davis et al., 1991) to be combined for analysis.”
MethodKito, N., Shinkoda, K., Yamasaki, T., Kanemura, N., Anan, M., Okanishi, N., Ozawa, J., & Moriyama, H. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.06.008 · Cited by 123
“A 7-link segmental model was developed to calculate hip, knee, and ankle kinematic and kinetic data by using inverse dynamics according to the techniques of Davis et al. (1991) and Vaughan et al.”
MethodRobotic-assisted gait training improves walking abilities in diplegic children with cerebral palsy
Wallard, L., Dietrich, G., Kerlirzin, Y., & Bredin, J. (2017) · European Journal of Paediatric Neurology · doi:10.1016/j.ejpn.2017.01.012 · Cited by 122
“An eight infrared camera Vicon® system (Oxford Metrics, Oxford, UK) was used to record three-dimensional total-body kinematic data to a sampling frequency of 200 Hz with the Plug-In-Gaitmarker-set.29 A total of 34 reflectivemarkerswere positioned on the skin overlying specific bony landmarks or anatomical positions of…”
MethodInterobserver Variability of Gait Analysis in Patients With Cerebral Palsy
Noonan, K. J., Halliday, S. E., Browne, R. H., O'Brien, S., Kayes, K. J., & Feinberg, J. R. (2003) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200305000-00001 · Cited by 122
Kinematics and kinetics of normal and planovalgus feet during walking
Saraswat, P., MacWilliams, B. A., Davis, R. B., & D'Astous, J. L. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.08.003 · Cited by 121
Self-citationThe influence of experience on knee mechanics during side-step cutting in females
Sigward, S. M., & Powers, C. M. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.03.003 · Cited by 121
“Joint centers for the hip, knee and ankle were determined in the standing trial (Davis et al., 1991).”
BackgroundMethodInfluentialThorstensson, C. A., Henriksson, M., von Porat, A., Hammarlund, C. S., & Roos, E. M. (2007) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2007.03.012 · Cited by 121
“Special markers, reflecting the infrared light from the cameras, were attached by a physical therapist with specific knowledge and experience within the area of motion analysis, over standardised landmarks according to the biomechanical model of Kadaba et al. (1990) 16 and Davis et al. (1991) 17 .”
The Golden Ratio of Gait Harmony: Repetitive Proportions of Repetitive Gait Phases
Iosa, M., Fusco, A., Marchetti, F., Morone, G., Caltagirone, C., Paolucci, S., & Peppe, A. (2013) · BioMed Research International · doi:10.1155/2013/918642 · Cited by 121
“…should be addressed to Marco Iosa; m.iosa@hsantalucia.it Received 11 April 2013; Revised 16 May 2013; Accepted 19 May 2013 Academic Editor: Hitoshi Mochizuki Copyright © 2013 Marco Iosa et al. This is an open access article distributed under the Creative Commons Attribution…”
BackgroundUse of the normalcy index for the evaluation of gait pathology
Romei, M., Galli, M., Motta, F., Schwartz, M. H., & Crivellini, M. (2003) · Gait & Posture · doi:10.1016/s0966-6362(03)00017-1 · Cited by 120
“[11], and subjects were asked to walk barefoot, at a self-selected speed, along a 10-m walkway containing a force platform at the mid-point.”
BackgroundTaylor, W. R., Kornaropoulos, E., Duda, G. N., Kratzenstein, S., Ehrig, R. M., Arampatzis, A., & Heller, M. O. W. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.05.005 · Cited by 120
Metadata
- Authors
- Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R.
- Affiliations
- Newmarket Hospital (GB)
- Corresponding author
- Davis, Roy B.
- Venue
- Human Movement Science
- Publisher
- Elsevier BV
- Published
- 1991-10
- Volume
- 10
- Issue
- 5
- Pages
- 575-587
- ISSN
- 0167-9457 (ISSN-L)
- OpenAlex
- W2049223406
- Semantic Scholar
- 3118efee89b3564a5d38c667dc6c3d19166fd412
- Cited by
- 3,086
- References
- 13
- Citations by year
- 2026: 121 · 2025: 162 · 2024: 153 · 2023: 157 · 2022: 166 · 2021: 177 · 2020: 179 · 2019: 175 · 2018: 187 · 2017: 165 · 2016: 167 · 2015: 155 · 2014: 151 · 2013: 142 · 2012: 126
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Human Movement Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- gait analysis, motion capture, retroreflective markers, joint kinetics, force plate, electromyography, data reduction, human locomotion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.