A gait analysis data collection and reduction technique
The DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Greenwood, D. T. (1965) · Medical Entomology and Zoology · Cited by 660
Justification of triaxial goniometer for the measurement of joint rotation
Chao, E. Y. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90044-5 · Cited by 355
The anthropometry of the manual work space for the seated subject
Dempster, W. T., Gabel, W. C., & Felts, W. J. L. (1959) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330170405 · Cited by 253
Walking patterns of men with parkinsonism.
Mp, M., Sb, S., Gm, G., & Wj, D. (1978) · PubMed · Cited by 199
Anatomic Guide for the Electromyographer
Tichauer, E. R. (1977) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-197712000-00042 · Cited by 193
Pre- and Postoperative Gait Analysis in Patients with Spastic Diplegia: A Preliminary Report
Gage, J. R., Fabian, D., Hicks, R. R., & Tashman, S. (1984) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-198411000-00012 · Cited by 120
Self-citationMeasurement of Gait Movements from Motion Picture Film
SUTHERLAND, D. H., & HAGY, J. L. (1972) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197254040-00009 · Cited by 105
Comment on criteria for patient evaluation tools
Brand, R. A., & Crowninshield, R. D. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90093-2 · Cited by 70
Gait analysis for decision-making in cerebral palsy.
Gage, J. R. (1983) · PubMed · Cited by 60
Self-citation
Cited by
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
“The data were processed at 120 Hz with VICON Workstation [42] using the standard model of the lower limbs included with the software [43]–[45].”
MethodThelen, D. G., & Anderson, F. C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.02.010 · Cited by 647
“Well-established inverse dynamics approaches have been developed for computing and comparing joint kinematics, moments, and powers across subjects (Davis et al., 1991).”
BackgroundMethodInfluentialGait analysis methods in rehabilitation
Baker, R. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-4 · Cited by 587
Step Length Reductions in Advanced Age: The Role of Ankle and Hip Kinetics
JudgeRoy, J. O., Davis, B., & Ounpuu, S. (1996) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/51a.6.m303 · Cited by 585
“The methodology has been reported earlier (20,21).”
Self-citationAdjustments to McConville et al. and Young et al. body segment inertial parameters
Dumas, R., Chèze, L., & Verriest, J.-P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.013 · Cited by 554
“These estimations are preferred to other regressions (Bell et al., 1990; Davis et al., 1991; Meskers et al., 1998; Seidel et al., 1995) because they provide at the same time the CJC and SJC as well as the LJC and HJC and because they are based on the same anatomical landmarks as McConville et al.…”
MethodInfluentialBoyd, R. N., & Graham, H. K. (1999) · European Journal of Neurology · doi:10.1111/j.1468-1331.1999.tb00031.x · Cited by 553
Human movement analysis using stereophotogrammetry
Della Croce, U., Leardini, A., Chiari, L., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.003 · Cited by 544
Kristianslund, E., Krosshaug, T., & van den Bogert, A. J. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.12.011 · Cited by 543
A new method for estimating joint parameters from motion data
Schwartz, M. H., & Rozumalski, A. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.009 · Cited by 512
“The protocol proposed by Davis (Davis et al., 1991), is used by a vast majority of clinical laboratories.”
External loading of the knee joint during running and cutting maneuvers
BESIER, T. F., LLOYD, D. G., COCHRANE, J. L., & ACKLAND, T. R. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200107000-00014 · Cited by 498
“Joint kinetic data were calculated using an inverse dynamic analysis as described by Kadaba et al. (9) and Davis et al. ( 6 ).”
MethodInfluentialA new anatomically based protocol for gait analysis in children
Leardini, A., Sawacha, Z., Paolini, G., Ingrosso, S., Nativo, R., & Benedetti, M. G. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.12.018 · Cited by 491
A Kinematics and Kinetic Comparison of Overground and Treadmill Running
RILEY, P. O., DICHARRY, J., FRANZ, J., CROCE, U. D., WILDER, R. P., & KERRIGAN, D. C. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181677530 · Cited by 463
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
“see [88–90]), define the AF axes from the location of subcutaneous and/or internal ALs [60].”
BackgroundExperimental identification and analytical modelling of human walking forces: Literature review
Racić, V., Pavić, A., & Brownjohn, J. (2009) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2009.04.020 · Cited by 455
Natural Progression of Gait in Children With Cerebral Palsy
Bell, K. J., Õunpuu, S., DeLuca, P. A., & Romness, M. (2002) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200209000-00020 · Cited by 454
“A comprehensive description of the motion data collection methodology has been previously published (2,3).”
MethodSelf-citationA survey of formal methods for determining the centre of rotation of ball joints
Ehrig, R. M., Taylor, W. R., Duda, G. N., & Heller, M. O. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.10.002 · Cited by 432
“Most of these approaches then apply empirical relations between externally palpable bone landmarks and the joint centres themselves (Bell et al., 1990; Kadaba et al., 1990; Davis et al., 1991; Frigo and Rabuffetti, 1998; Vaughan et al., 1999).”
BackgroundAn index for quantifying deviations from normal gait
Schutte, L. M., Narayanan, U., Stout, J. L., Selber, P., Gage, J. R., & Schwartz, M. H. (2000) · Gait & Posture · doi:10.1016/s0966-6362(99)00047-8 · Cited by 416
“VCM calculates joint angles as ordered rotations between anatomically aligned reference frames associated with adjacent body segments [1,13].”
BackgroundMethodSelf-citationValidation of a functional method for the estimation of hip joint centre location
Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00148-1 · Cited by 415
“and from Davis et al. (1991):”
MethodSagittal gait patterns in spastic diplegia
Rodda, J. M., Graham, H. K., Carson, L., Galea, M. P., & Wolfe, R. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b2.13878 · Cited by 410
Human movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398
“(a) three technical markers (filled circles) for each bony segment; the cluster technical frame is constructed using the following rule: p1 is the position vector of the frame origin, the y axis is oriented as ( p2 − p1), and the x axis as(p3 − p1)× (p2 − p1); the z axis is oriented so that a right handed frame is con…”
BackgroundGait dynamics on an inclined walkway
McIntosh, A. S., Beatty, K. T., Dwan, L. N., & Vickers, D. R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.07.025 · Cited by 384
“The segment and joint kinematics were calculated according to Davis et al. (1991) and Kadaba et al. (1990).”
BackgroundMethodInfluentialCompressive tibiofemoral force during crouch gait
Steele, K. M., DeMers, M. S., Schwartz, M. H., & Delp, S. L. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.023 · Cited by 378
“Motion analysis data was collected at Gillette Children's Specialty Healthcare (St. Paul, MN) using a 12-camera system (Vicon Motion Systems, Lake Forest, CA), four force plates (AMTI, Watertown, MA), and a standard marker protocol [20].”
Collins, T. D., Ghoussayni, S. N., Ewins, D. J., & Kent, J. A. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.04.004 · Cited by 365
“consistent with ISB recommendations [15]) while HH used regression equations [19].”
MethodHarrington, M. E., Zavatsky, A. B., Lawson, S. E. M., Yuan, Z., & Theologis, T. N. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.003 · Cited by 365
“Method I (Davis et al., 1991) was implemented using leg length (LL, measured manually) and pelvic width (PW, the inter-ASIS distance from the MRI scans).”
MethodThe Effect of Angle and Velocity on Change of Direction Biomechanics: An Angle-Velocity Trade-Off
Dos’Santos, T., Thomas, C., Comfort, P., & Jones, P. A. (2018) · Sports Medicine · doi:10.1007/s40279-018-0968-3 · Cited by 358
Quantitative comparison of five current protocols in gait analysis
Ferrari, A., Benedetti, M. G., Pavan, E., Frigo, C., Bettinelli, D., Rabuffetti, M., Crenna, P., & Leardini, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.11.009 · Cited by 334
Corazza, S., Mündermann, L., Chaudhari, A. M., Demattio, T., Cobelli, C., & Andriacchi, T. P. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9122-8 · Cited by 325
Deep neural networks enable quantitative movement analysis using single-camera videos
Kidziński, Ł., Yang, B., Hicks, J. L., Rajagopal, A., Delp, S. L., & Schwartz, M. H. (2020) · Nature Communications · doi:10.1038/s41467-020-17807-z · Cited by 321
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318
The evolution of clinical gait analysis
Sutherland, D. H. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00004-8 · Cited by 314
“Many papers have been published both by Gillette Children’s Hospital and Newington/Children’s Hospital of Connecticut covering a variety of subjects, including: running patterns of normal children [61] [62], outcome of multilevel surgery in cerebral palsy [63], stiff-knee gait [64,65], the utility of basing treatment…”
MethodKrosshaug, T., Steffen, K., Kristianslund, E., Nilstad, A., Mok, K.-M., Myklebust, G., Andersen, T. E., Holme, I., Engebretsen, L., & Bahr, R. (2016) · The American Journal of Sports Medicine · doi:10.1177/0363546515625048 · Cited by 313
Patellofemoral stress during walking in persons with and without patellofemoral pain
HEINO BRECHTER, J., & POWERS, C. M. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200210000-00009 · Cited by 309
User‐adaptive control of a magnetorheological prosthetic knee
Herr, H., & Wilkenfeld, A. (2003) · Industrial Robot: An International Journal · doi:10.1108/01439910310457706 · Cited by 293
“The data were processed at 120 Hz with VICON Workstation (Oxford Metrics, UK) using the standard model of the lower limbs included with the software (Davis et al., 1991; Kadaba et al., 1990; Ramakrishnan et al., 1987).”
MethodDejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286
Three-dimensional gait analysis of obese adults
Lai, P. P. K., Leung, A. K. L., Li, A. N. M., & Zhang, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.02.004 · Cited by 283
An optimized protocol for hip joint centre determination using the functional method
Camomilla, V., Cereatti, A., Vannozzi, G., & Cappozzo, A. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.02.008 · Cited by 269
“Regression parameters have been obtained by analysing relatively small samples of isolated pelvises (Seidel et al., 1995) or, in vivo, through medical imaging (Andriacchi et al, 1980; Bell et al., 1989, 1990; Crowninshield et al., 1978; Davis et al., 1991; Tylkowski et al., 1982).”
BackgroundMethodThe Biomechanics Of Walking And Running
Õunpuu, S. (1994) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30289-1 · Cited by 278
Self-citationJoint kinematics estimate using wearable inertial and magnetic sensing modules
Picerno, P., Cereatti, A., & Cappozzo, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.003 · Cited by 262
An anatomically based protocol for the description of foot segment kinematics during gait
Leardini, A., Benedetti, M. G., Catani, F., Simoncini, L., & Giannini, S. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00008-x · Cited by 257
“The current gait analysis practice uses a single rigid body representation of the foot [3,4].”
MethodThe Effect of Cam FAI on Hip and Pelvic Motion during Maximum Squat
Lamontagne, M., Kennedy, M. J., & Beaulé, P. E. (2009) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-008-0620-x · Cited by 249
“[5] using Vicon(1) Workstation processing software.”
DeLuca, P. A., Davis, R. B., ??unpuu, S., Rose, S., & Sirkin, R. (1997) · Journal of Pediatric Orthopaedics · doi:10.1097/00004694-199709000-00007 · Cited by 246
Self-citationNormalisation of gait EMGs: a re-examination
Burden, A. M., Trew, M., & Baltzopoulos, V. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(03)00082-8 · Cited by 244
“More precise locations of these markers can be found in Davis et al. [8].”
BackgroundEffects of hip joint centre mislocation on gait analysis results
Stagni, R., Leardini, A., Cappozzo, A., Grazia Benedetti, M., & Cappello, A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00093-2 · Cited by 241
Lim, B., Hinman, R. S., Wrigley, T. V., Sharma, L., & Bennell, K. L. (2008) · Arthritis Care & Research · doi:10.1002/art.23823 · Cited by 240
Ristanis, S., Stergiou, N., Patras, K., Vasiliadis, H. S., Giakas, G., & Georgoulis, A. D. (2005) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2005.08.032 · Cited by 231
Upper‐body kinematics in team‐handball throw, tennis serve, and volleyball spike
Wagner, H., Pfusterschmied, J., Tilp, M., Landlinger, J., von DUVILLARD, S. P., & Müller, E. A. (2012) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.2012.01503.x · Cited by 230
“To calculate the joint positions, a 3D model (Plug-In Gait Model, Vicon Peak) was used (Davis et al., 1991).”
Gait in adolescent idiopathic scoliosis: kinematics and electromyographic analysis
Mahaudens, P., Banse, X., Mousny, M., & Detrembleur, C. (2009) · European Spine Journal · doi:10.1007/s00586-009-0899-7 · Cited by 229
“These measurements allowed computation of the 3D angular displacement and angular speed of shoulder, pelvis, hip, knee, and ankle [10].”
Ristanis, S., Giakas, G., Papageorgiou, C. D., Moraiti, T., Stergiou, N., & Georgoulis, A. D. (2003) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-003-0428-x · Cited by 227
Hak, L., Houdijk, H., Steenbrink, F., Mert, A., van der Wurff, P., Beek, P. J., & van Dieën, J. H. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.03.005 · Cited by 224
“Local pelvis reference frames were defined following the ‘Conventional Gait Model’ [18,19].”
BackgroundMethodThe Heidelberg foot measurement method: Development, description and assessment
Simon, J., Doederlein, L., McIntosh, A. S., Metaxiotis, D., Bock, H. G., & Wolf, S. I. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.07.003 · Cited by 223
Kotsifaki, A., Van Rossom, S., Whiteley, R., Korakakis, V., Bahr, R., Sideris, V., & Jonkers, I. (2022) · British Journal of Sports Medicine · doi:10.1136/bjsports-2021-104692 · Cited by 221
“23 Three marker clusters replaced the single maker laterally on each thigh and shank since cluster-based models have less intersubject variance of frontal plane variables.”
Schache, A. G., BLANCH, P. D., Rath, D. A., Wrigley, T. V., Starr, R., & Bennell, K. L. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00061-4 · Cited by 221
‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0545-x · Cited by 218
Stoquart, G., Detrembleur, C., & Lejeune, T. (2008) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2008.02.002 · Cited by 217
“From Euler angles [3], it allowed the computation of angular displacements of the pelvis, hip, knee and ankle in the three planes of space.”
MethodInfluentialHamstrings and psoas lengths during normal and crouch gait: Implications for muscle‐tendon surgery
Delp, S. L., Arnold, A. S., Speers, R. A., & Moore, C. A. (1996) · Journal of Orthopaedic Research · doi:10.1002/jor.1100140123 · Cited by 217
Ageberg, E., Bennell, K. L., Hunt, M. A., Simic, M., Roos, E. M., & Creaby, M. W. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-265 · Cited by 216
“The hip joint centre was defined using the equations of Davis et al [27].”
MethodFamiliarization to treadmill running in young unimpaired adults
Lavcanska, V., Taylor, N. F., & Schache, A. G. (2005) · Human Movement Science · doi:10.1016/j.humov.2005.08.001 · Cited by 214
Femoroacetabular impingement alters hip and pelvic biomechanics during gait
Kennedy, M. J., Lamontagne, M., & Beaulé, P. E. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.02.008 · Cited by 214
“[17] and Kadaba et al.”
Energy cost, mechanical work, and efficiency of hemiparetic walking
Detrembleur, C., Dierick, F., Stoquart, G., Chantraine, F., & Lejeune, T. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00193-5 · Cited by 213
“Four CCD infrared cameras measured the co-ordinates, in the 3 spatial planes, of 10 reflective markers positioned on specific anatomical landmarks to compute the angular displacements of pelvis, hip, knee, and ankle based on Euler angles and Newtonian mechanics [26].”
MethodThe effect of total hip arthroplasty surgical approach on gait
Madsen, M. S., Ritter, M. A., Morris, H. H., Meding, J. B., Berend, M. E., Faris, P. M., & Vardaxis, V. G. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(03)00151-7 · Cited by 212
Biomechanical ToolKit: Open-source framework to visualize and process biomechanical data
Barre, A., & Armand, S. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.01.012 · Cited by 209
Wouda, F. J., Giuberti, M., Bellusci, G., Maartens, E., Reenalda, J., van Beijnum, B.-J. F., & Veltink, P. H. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00218 · Cited by 207
“Optical kinematic 1https://www.vicon.com/downloads/documentation/plug-in-gait-product-guide data was processed using Plug-in Gait (Kadaba et al., 1990; Davis et al., 1991).”
MethodInfluentialMuscle Contributions to Support and Progression during Single-Limb Stance in Crouch Gait
Steele, K. M., Seth, A., Hicks, J. L., Schwartz, M. S., & Delp, S. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.04.003 · Cited by 206
“Motion analysis data were collected and kinematics determined using a 12-camera system (Vicon Motion Systems, Lake Forest, CA) and a standard marker measurement protocol (Davis et al., 1991).”
MethodGait characterization via dynamic joint stiffness
Davis, R. B., & DeLuca, P. A. (1996) · Gait & Posture · doi:10.1016/0966-6362(95)01045-9 · Cited by 208
Self-citationPiazza, S. J., Okita, N., & Cavanagh, P. R. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00052-5 · Cited by 199
“, 1999) and by predictive approaches in which the hip center is located relative to palpated anatomical landmarks (Andriacchi et al., 1980; Davis et al., 1991; Kirkwood et al., 1999; Seidel et al., 1995; Tylkowski et al., 1982; Vaughan et al., 1992).”
BackgroundTibial Rotation is Not Restored after ACL Reconstruction with a Hamstring Graft
Georgoulis, A. D., Ristanis, S., Chouliaras, V., Moraiti, C., & Stergiou, N. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e31802b4a0a · Cited by 199
“We used a six-camera optoelectronic system (Peak Performance Technologies, Inc., Englewood, CO) sampling at 50 Hz to capture the movements of 15 reflective markers placed on the selected bony landmarks of the lower limbs and the pelvis placed according the model described by Davis et al.9 At the time of data collectio…”
MethodInfluentialImproved Gait After Repetitive Locomotor Training in Children with Cerebral Palsy
Smania, N., Bonetti, P., Gandolfi, M., Cosentino, A., Waldner, A., Hesse, S., Werner, C., Bisoffi, G., Geroin, C., & Munari, D. (2011) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318201741e · Cited by 198
“Gait Analysis: Three-dimensional gait analysis (Vicon; Oxford Metrics, Oxford, UK) by means of a motion capture system consisting of six infrared cameras was carried out according to a standard marker placement protocol.(24) The participants were required to walk at their self-selected speeds.”
MethodGait posture estimation using wearable acceleration and gyro sensors
Takeda, R., Tadano, S., Natorigawa, A., Todoh, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.016 · Cited by 197
Body of evidence supporting the clinical use of 3D multisegment foot models: A systematic review
Deschamps, K., Staes, F. F. G. M., Roosen, P., Nobels, F. R. E., Desloovere, K., Bruyninckx, H., & Matricali, G. A. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2010.12.018 · Cited by 203
“Although this technique has some weaknesses related to skin motion artifact and the difficulty of defining specific bones in the foot [8–11], it has the potential to overcome the weaknesses of the single-segment foot models,whichareoftenused inclinical gait analysis, associatedwith conventional lower limbmodels [12–15…”
BackgroundFong, D. T.-P., Hong, Y., Shima, Y., Krosshaug, T., Yung, P. S.-H., & Chan, K.-M. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546508328102 · Cited by 196
Arnold, A. S., Liu, M. Q., Schwartz, M. H., Õunpuu, S., & Delp, S. L. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.03.003 · Cited by 193
“Each subject underwent threedimensional gait analysis [28] and clinical assessment.”
MethodSelf-citationTaylor, M. J. D., Dabnichki, P., & Strike, S. C. (2005) · Human Movement Science · doi:10.1016/j.humov.2005.07.005 · Cited by 192
Sex differences in whole body gait kinematics at preferred speeds
Bruening, D. A., Frimenko, R. E., Goodyear, C. D., Bowden, D. R., & Fullenkamp, A. M. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2014.12.011 · Cited by 191
Andersen, M. S., Damsgaard, M., MacWilliams, B., & Rasmussen, J. (2010) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840903067080 · Cited by 188
“Anatomical landmark methods use palpation of bony landmarks to identify the segment and joint parameters using experimentally determined relationships between these (Bell et al. 1990; Davis et al. 1991; Vaughan et al. 1992).”
MethodDerrick, T. R., van den Bogert, A. J., Cereatti, A., Dumas, R., Fantozzi, S., & Leardini, A. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109533 · Cited by 187
Kinematic Analysis of Volleyball Spike Jump
Wagner, H., Tilp, M., von DUVILLARD, S. P., & Mueller, E. (2009) · International Journal of Sports Medicine · doi:10.1055/s-0029-1224177 · Cited by 187
Xergia, S. A., Pappas, E., Zampeli, F., Georgiou, S., & Georgoulis, A. D. (2013) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2013.3967 · Cited by 186
Fernández-González, P., Koutsou, A., Cuesta-Gómez, A., Carratalá-Tejada, M., Miangolarra-Page, J. C., & Molina-Rueda, F. (2020) · Sensors · doi:10.3390/s20113154 · Cited by 185
Performance and kinematics of various throwing techniques in team-handball.
Wagner, H., Pfusterschmied, J., von DUVILLARD, S. P., & Müller, E. A. (2011) · Europe PMC (PubMed Central) · Cited by 185
Lencioni, T., Carpinella, I., Rabuffetti, M., Marzegan, A., & Ferrarin, M. (2019) · Scientific Data · doi:10.1038/s41597-019-0323-z · Cited by 184
The effect of backpack load on the gait of normal adolescent girls
Chow, D. H., Kwok, M. L., Au-Yang, A. C., Holmes, A. D., Cheng, J. C., Yao, F. Y., & Wong, M. (2005) · Ergonomics · doi:10.1080/00140130500070921 · Cited by 183
“Standard marker positions (Davis et al. 1991) were used and two knee alignment devices (Oxford Metrics, Oxford, UK) were used to aid location of the flexion-extension axes of the knees, and also to ensure that the markers on the lateral aspects of the thighs (table 1) were in the plane containing…”
MethodRomkes, J., & Brunner, R. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00178-3 · Cited by 191
“[5].”
Palermo, E., Rossi, S., Marini, F., Patanè, F., & Cappa, P. (2014) · Measurement · doi:10.1016/j.measurement.2014.03.004 · Cited by 182
Uncertainties in inverse dynamics solutions: A comprehensive analysis and an application to gait
Riemer, R., Hsiao‐Wecksler, E. T., & Zhang, X. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2007.07.012 · Cited by 184
“They also compared their results with values obtained using a traditional method [28], and found that the difference between methods at the hip was up to 16.”
ResultRepeatability of an optimised lower body model
Charlton, I., Tate, P., Smyth, P., & Roren, L. (2003) · Gait & Posture · doi:10.1016/j.gaitpost.2003.09.004 · Cited by 182
Ferrari, A., Cutti, A. G., Garofalo, P., Raggi, M., Heijboer, M., Cappello, A., & Davalli, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0544-y · Cited by 181
Smith, A. J., Lloyd, D. G., & Wood, D. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(03)00184-0 · Cited by 180
Gutierrez-Farewik, E. M., Bartonek, Å., & Saraste, H. (2006) · Human Movement Science · doi:10.1016/j.humov.2005.11.001 · Cited by 180
Kotsifaki, A., Whiteley, R. J., Rossom, S. V., Korakakis, V., Bahr, R., Sideris, V., Graham‐Smith, P., & Jonkers, I. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103677 · Cited by 181
MOtoNMS: A MATLAB toolbox to process motion data for neuromusculoskeletal modeling and simulation
Mantoan, A., Pizzolato, C., Sartori, M., SAWACHA, Z., Cobelli, C., & Reggiani, M. (2015) · Source Code for Biology and Medicine · doi:10.1186/s13029-015-0044-4 · Cited by 181
“We are also planning to distribute a database of configuration files for themost popular acquisition protocols [44–46].”
MethodJoint stiffness and gait pattern evaluation in children with Down syndrome
Galli, M., Rigoldi, C., Brunner, R., Virji‐Babul, N., & Albertini, G. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.03.001 · Cited by 174
Electromyography in the biomechanical analysis of human movement and its clinical application
Kleissen, R. F. M., Buurke, J. H., Harlaar, J., & Zilvold, G. (1998) · Gait & Posture · doi:10.1016/s0966-6362(98)00025-3 · Cited by 174
Rationale for Training Programs to Reduce Anterior Cruciate Ligament Injuries in Australian Football
Lloyd, D. G. (2001) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2001.31.11.645 · Cited by 146
Loading characteristics of females exhibiting excessive valgus moments during cutting
Sigward, S. M., & Powers, C. M. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.04.003 · Cited by 173
“, Oxford, England) was used to quantify hip and knee kinematics in the sagittal, frontal and transverse planes and knee frontal plane moments (Davis et al., 1991; Kadaba et al., 1990).”
MethodReliability of four models for clinical gait analysis
Kainz, H., Graham, D., Edwards, J., Walsh, H. P. J., Maine, S., Boyd, R. N., Lloyd, D. G., Modenese, L., & Carty, C. P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.001 · Cited by 173
Estimation of the hip joint centre in human motion analysis: A systematic review
Kainz, H., Carty, C. P., Modenese, L., Boyd, R. N., & Lloyd, D. G. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.02.005 · Cited by 177
“Predictive methods use regression equations based on experimental data from medical imaging (e.g. Bell et al., 1990; Davis et al., 1991) or cadaveric studies (e.”
MethodInfluential
Metadata
- Authors
- Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R.
- Affiliations
- Newmarket Hospital (GB)
- Corresponding author
- Davis, Roy B.
- Venue
- Human Movement Science
- Publisher
- Elsevier BV
- Published
- 1991-10
- Volume
- 10
- Issue
- 5
- Pages
- 575-587
- ISSN
- 0167-9457 (ISSN-L)
- OpenAlex
- W2049223406
- Semantic Scholar
- 3118efee89b3564a5d38c667dc6c3d19166fd412
- Cited by
- 3,086
- References
- 13
- Citations by year
- 2026: 121 · 2025: 162 · 2024: 153 · 2023: 157 · 2022: 166 · 2021: 177 · 2020: 179 · 2019: 175 · 2018: 187 · 2017: 165 · 2016: 167 · 2015: 155 · 2014: 151 · 2013: 142 · 2012: 126
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Human Movement Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- gait analysis, motion capture, retroreflective markers, joint kinetics, force plate, electromyography, data reduction, human locomotion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.