A gait analysis data collection and reduction technique
The DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Greenwood, D. T. (1965) · Medical Entomology and Zoology · Cited by 660
Justification of triaxial goniometer for the measurement of joint rotation
Chao, E. Y. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90044-5 · Cited by 355
The anthropometry of the manual work space for the seated subject
Dempster, W. T., Gabel, W. C., & Felts, W. J. L. (1959) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330170405 · Cited by 253
Walking patterns of men with parkinsonism.
Mp, M., Sb, S., Gm, G., & Wj, D. (1978) · PubMed · Cited by 199
Anatomic Guide for the Electromyographer
Tichauer, E. R. (1977) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-197712000-00042 · Cited by 193
Pre- and Postoperative Gait Analysis in Patients with Spastic Diplegia: A Preliminary Report
Gage, J. R., Fabian, D., Hicks, R. R., & Tashman, S. (1984) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-198411000-00012 · Cited by 120
Self-citationMeasurement of Gait Movements from Motion Picture Film
SUTHERLAND, D. H., & HAGY, J. L. (1972) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197254040-00009 · Cited by 105
Comment on criteria for patient evaluation tools
Brand, R. A., & Crowninshield, R. D. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90093-2 · Cited by 70
Gait analysis for decision-making in cerebral palsy.
Gage, J. R. (1983) · PubMed · Cited by 60
Self-citation
Cited by
Items 601–700 of 1,006
Effects of unilateral backpack carriage on biomechanics of gait in adolescents: a kinematic analysis
Özgül, B., Akalan, N. E., Kuchimov, S., Uygur, F., Temelli, Y., & Polat, G. (2012) · Acta Orthopaedica et Traumatologica Turcica · doi:10.3944/aott.2012.2678 · Cited by 49
“Markers were located on the bodies according to the Helen Hayes protocol.([20]) The experimental procedure was approved by the Hacettepe University Medical Ethics Committee (dated 08/13/2009, no.”
MethodFarr, S., Kranzl, A., Pablik, E., Kaipel, M., & Ganger, R. (2014) · Journal of Orthopaedic Research® · doi:10.1002/jor.22684 · Cited by 49
“A regression equation was used to define the hip joint center.(27) Knee and ankle joint axis were determined by a medial and lateral marker on the epicondyle of the femur and the medial/lateral tip of the malleolus.”
MethodIcco, R. D., Tassorelli, C., Berra, E., Bolla, M., Pacchetti, C., & Sandrini, G. (2015) · Parkinson s Disease · doi:10.1155/2015/978590 · Cited by 49
Gray, A. D., Willis, B. W., Skubic, M., Huo, Z., Razu, S. S., Sherman, S. L., Guess, T. M., Jahandar, A., Gulbrandsen, T. R., Miller, S., et al. (2017) · Sports Health A Multidisciplinary Approach · doi:10.1177/1941738117726323 · Cited by 49
“Sixteen skin-surface retroreflective markers were placed on the trunk and legs according to the protocol of the lower body Plug-inGait model.(8) Four additional markers were placed on the medial epicondyle of the knee and medial malleoli of the ankle to estimate the thigh rotation offset, shank rotation offset, and ti…”
MethodTraining for mobility with exoskeleton robot in spinal cord injury patients: a pilot study
Sale, P., Russo, E. F., Scarton, A. M., Calabrò, R. S., Masiero, S., & Filoni, S. (2018) · European Journal of Physical and Rehabilitation Medicine · doi:10.23736/s1973-9087.18.04819-0 · Cited by 49
Leboeuf, F., Reay, J., Jones, R. K., & Sangeux, M. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.02.010 · Cited by 49
The Conventional Gait Model - Success and Limitations
Baker, R. J., Leboeuf, F., Reay, J., & Sangeux, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-30808-1_25-2 · Cited by 52
Celletti, C., Galli, M., Cimolin, V., Castori, M., Tenore, N., Albertini, G., & Camerota, F. (2013) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2013.09.019 · Cited by 49
Robert, T., Chèze, L., Dumas, R., & Verriest, J. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.11.014 · Cited by 49
Ranavolo, A., Don, R., Draicchio, F., Bartolo, M., Serrao, M., Padua, L., Cipolla, G., Pierelli, F., Iavicoli, S., & Sandrini, G. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2012.07.004 · Cited by 50
“In the biomechanical models most widely used for evaluating upper and lower limb motion, the spine is commonly considered a rigid body (Davis et al., 1991), thereby introducing an unacceptable approximation of its actual behaviour.”
BackgroundThe association of quadriceps strength with the knee adduction moment in medial knee osteoarthritis
Lim, B., Kemp, G., Metcalf, B., Wrigley, T. V., Bennell, K. L., Crossley, K. M., & Hinman, R. S. (2009) · Arthritis Care & Research · doi:10.1002/art.24278 · Cited by 49
“axis system located in the distal segment of the joint (40).”
BackgroundStief, F., Böhm, H., Dussa, C. U., Multerer, C., Schwirtz, A., Imhoff, A. B., & Döderlein, L. (2014) · The Knee · doi:10.1016/j.knee.2014.03.004 · Cited by 49
Barbic, F., Galli, M., Vecchia, L. A. D., Canesi, M., Cimolin, V., Porta, A., Bari, V., Cerri, G., Dipaola, F., Bassani, T., et al. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01160.2013 · Cited by 49
Biomechanical Attributes of Lunging Activities for Older Adults
Flanagan, S. P., Wang, M., Greendale, G. A., Azen, S. P., & Salem, G. J. (2004) · The Journal of Strength and Conditioning Research · doi:10.1519/00124278-200408000-00037 · Cited by 49
Mobility assessment of patients with facioscapulohumeral dystrophy
Iosa, M., Mazzà, C., Frusciante, R., Zok, M., Aprile, I. G., Ricci, E., & Cappozzo, A. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.07.013 · Cited by 49
“A 9-camera Vicon MX stereophotogrammetric system (Vicon, Oxford, UK, fs = 120 samples/s) was used to reconstruct the 3D position of 39 retro-reflective spherical markers located on the subjects skin according to the Plug-in Gait protocol (Davis et al., 1991; Kadaba et al., 1990).”
MethodThe effects of low arched feet on foot rotation during gait in children with D own syndrome
Galli, M., Cimolin, V., Rigoldi, C., Pau, M., Costici, P. F., & Albertini, G. (2013) · Journal of Intellectual Disability Research · doi:10.1111/jir.12087 · Cited by 49
The influence of dive direction on the movement characteristics for elite football goalkeepers
Spratford, W., Mellifont, R. B., & Burkett, B. J. (2009) · Sports Biomechanics · doi:10.1080/14763140903229526 · Cited by 49
“The algorithms used are described by Davis et al. (1991) and Ramakrishnan et al. (1987).”
Serrao, M., Chini, G., Casali, C., Conte, C., Rinaldi, M., Ranavolo, A., Marcotulli, C., Leonardi, L., Fragiotta, G., Bini, F., et al. (2016) · The Cerebellum · doi:10.1007/s12311-016-0837-2 · Cited by 49
Gender differences in the knee joint loadings during gait
Obrębska, P., Skubich, J., & Piszczatowski, S. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.05.017 · Cited by 48
Joint kinematics following bi-compartmental knee replacement during daily life motor tasks
Leffler, J., Scheys, L., Planté-Bordeneuve, T., Callewaert, B., Labey, L., Bellemans, J., & Franz, A. R. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.04.008 · Cited by 48
“Workstation and Polygon software (Vicon, Oxford, UK) were used to identify motor task events and to derive the kinematics from the acquired data [17–19].”
MethodPetersen, M. K., Andersen, N. T., Mogensen, P., Voight, M., & Søballé, K. (2010) · International Orthopaedics · doi:10.1007/s00264-010-1040-6 · Cited by 48
“The 3D gait analysis was carried out using a Vicon 612 eight-camera system (Vicon, Oxford, UK) operating at 100 Hz and using a Helen Hayes marker set-up [4, 11].”
MethodAccuracy of KinectOne to quantify kinematics of the upper body
Kuster, R. P., Heinlein, B., Bauer, C. M., & Graf, E. S. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.04.004 · Cited by 48
“Before data collection, each subject was equipped with 39 reflective markers, according to the plug-in-gait full body model [11].”
MethodBiomechanical changes associated with femoral derotational osteotomy
MacWilliams, B. A., McMulkin, M. L., Davis, R. B., Westberry, D. E., Baird, G. O., & Stevens, P. M. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.07.002 · Cited by 48
Self-citationCamerota, F., Celletti, C., Sipio, E. D., Fino, C. D., Simbolotti, C., Germanotta, M., Massimiliano Mirabella, A., Padua, L., & Nociti, V. (2016) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2016.11.025 · Cited by 48
Kainz, H., Carty, C. P., Maine, S., Walsh, H. P. J., Lloyd, D. G., & Modenese, L. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.002 · Cited by 48
“Most clinical gait laboratories use variants of the conventional gait model [2,3], included in most commercially available motion capture systems.”
MethodOptimal markers’ placement on the thorax for clinical gait analysis
Armand, S., Sangeux, M., & Baker, R. J. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.06.016 · Cited by 48
Effects of ankle foot orthosis in stiff knee gait in adults with hemiplegia
Gatti, M. A., Freixes, O., Fernández, S. A., Rivas, M. E., Crespo, M., Waldman, S. V., & Olmos, L. E. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.08.015 · Cited by 48
“Retro reflective markers were placed following the gait analysis technique proposed by Davis et al. (1991). The studied variables were obtained with the software SMART BTS Analyzer 1.”
MethodLower-Limb Joint Coordination Pattern in Obese Subjects
Ranavolo, A., Donini, L. M., Marí, S. M., Serrao, M., Silvetti, A., Iavicoli, S., Cava, E., Asprino, R., Pinto, A., & Draicchio, F. (2012) · BioMed Research International · doi:10.1155/2013/142323 · Cited by 49
“An optoelectronic motion analysis system (SMART-E System, BTS, Italy), consisting of eight infrared cameras (operating at 120Hz), was used to detect themovements of sphericalmarkers (15mmdiameter) covered with aluminium powder re�ecting material placed over prominent bony landmarks on the skin according to Davis’s pro…”
MethodKinematic analysis of hip and knee rotation and other contributors to ballet turnout
Quanbeck, A. E., Russell, J. A., Handley, S. C., & Quanbeck, D. S. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1164335 · Cited by 48
“Based on the anatomical coordinate systems (x, y, z axes aligned with the body), we used Euler angles to rotate each axis of the distal segment coordinate system until it aligned with the corresponding axis of the proximal coordinate system (Davis et al., 1991; Kadaba, Ramakrishnan, & Wootten, 1990).”
MethodKnee kinetics during walking at different speeds in people who have undergone total knee replacement
McClelland, J. A., Webster, K. E., Feller, J. A., & Menz, H. B. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.04.009 · Cited by 48
Effects of decision making on landing mechanics as a function of task and sex
Mache, M. A., Hoffman, M. A., Hannigan, K., Golden, G. M., & Pavol, M. J. (2012) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2012.10.001 · Cited by 47
Yorozu, A., Moriguchi, T., & Takahashi, M. (2015) · Sensors · doi:10.3390/s150922451 · Cited by 47
“In many cases, force plates [11,12] or three-dimensional motion measuring devices, such as the VICON system [13,14], have been used to measure the walking parameters with high reliability.”
MethodEffectiveness of an automatic tracking software in underwater motion analysis.
Magalhães, F. A., SAWACHA, Z., Michele, R. D., Cortesi, M., Gatta, G., & Fantozzi, S. (2013) · Europe PMC (PubMed Central) · Cited by 47
Passmore, E., & Sangeux, M. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.02.006 · Cited by 47
Christoforidou, Α., Patikas, D., Bassa, E. I., Paraschos, I., Lazaridis, S. N., Christoforidis, C., & Kotzamanidis, C. (2016) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2016.11.003 · Cited by 47
“Sixteen reflective markers (14 mm diameter spheres) were placed at anatomical bony landmarks of lower extremities according to Davis et al. (1991).”
MethodMentiplay, B. F., & Clark, R. A. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.05.033 · Cited by 49
Introduction to musculoskeletal modelling
Andersen, M. S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819531-4.00004-3 · Cited by 47
Kim, J., Hwang, S., Sohn, R., Lee, Y., & Kim, Y. (2011) · Applied Bionics and Biomechanics · doi:10.1155/2011/530375 · Cited by 47
Effective marker placement for functional identification of the centre of rotation at the hip
Kratzenstein, S., Kornaropoulos, E., Ehrig, R. M., Heller, M. O. W., Pöpplau, B. M., & Taylor, W. R. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.04.011 · Cited by 48
“However, such methods have not been able to demonstrate consistent advantages over more traditional regression based approaches [19–22], possibly due to issues of marker placement and the non-linear distribution of STAs across a segment [12,23,24].”
BackgroundKottink, A. I. R., Tenniglo, M. J. B., de Vries, W., Hermens, H. J., & Buurke, J. H. (2012) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0909 · Cited by 47
Development and validation of a low-cost, portable and wireless gait assessment tool
MacLeod, C. A., Conway, B. A., Allan, D., & Galen, S. S. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.11.011 · Cited by 47
“[15] and Kadaba et al.”
(2005) · CRC Press eBooks · doi:10.1201/b14109 · Cited by 47
Gait Analysis in Advanced Parkinson's Disease – Effect of Levodopa and Tolcapone
Shan, D., Lee, S.-J., Chao, L.-Y., & Yeh, S.-I. (2001) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100052598 · Cited by 48
Cognitive control of gait and balance in patients with chronic stroke and Parkinson's disease
Smulders, K. (2014) · Radboud Repository (Radboud University) · Cited by 51
von Porat, A., Henriksson, M., Holmström, E., Thorstensson, C. A., Mattsson, L., & Roos, E. M. (2006) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-006-0071-4 · Cited by 46
“Calculation methods and model assumptions have been described in detail earlier [11, 25, 38].”
MethodPalermo, E., Rossi, S., Patanè, F., & Cappa, P. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/3/399 · Cited by 46
Lower Extremity Kinematics and Kinetics When Landing From Unloaded and Loaded Jumps
Janssen, I., Sheppard, J. M., Dingley, A. A., Chapman, D. W., & Spratford, W. (2012) · Journal of Applied Biomechanics · doi:10.1123/jab.28.6.687 · Cited by 46
Mok, K.-M., Bahr, R., & Krosshaug, T. (2015) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12640 · Cited by 46
“We calculated joint moments with inverse dynamics using recursive Newton–Euler equations of motion as described by Davis et al. (1991) and projected onto the three rotational axes of the joint according to the joint coordinate system standard (Grood & Suntay, 1983; Kristianslund et al., 2014).”
MethodSubject-specific musculoskeletal modelling in patients before and after total hip arthroplasty
Wesseling, M., Groote, F. D., Meyer, C., Corten, K., Simon, J.-P., Desloovere, K., & Jonkers, I. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1181174 · Cited by 46
“A Plug-in-gait marker set (Davis et al. 1991) of the lower limb and trunk was used and additionally three-cluster markers were placed on the upper and lower legs.”
MethodHorsak, B., Schwab, C., Baca, A., Greber‐Platzer, S., Kreissl, A., Nehrer, S., Keilani, M. Y., Crevenna, R., Kranzl, A., & Wondrasch, B. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.02.032 · Cited by 46
Aprile, I. G., Iacovelli, C., Goffredo, M., Cruciani, A., Galli, M., Simbolotti, C., Pecchioli, C., Padua, L., Galafate, D., Pournajaf, S., et al. (2019) · Neurorehabilitation · doi:10.3233/nre-192778 · Cited by 46
“The Davis marker set (Davis et al., 1991), which includes 22 retro-reflective markers was adopted, and anthropometric data were collected for each subject (Winter, 2009).”
Squat Lifting Imposes Higher Peak Joint and Muscle Loading Compared to Stoop Lifting
van der Have, A., Rossom, S. V., & Jonkers, I. (2019) · Applied Sciences · doi:10.3390/app9183794 · Cited by 46
Mobarak, R., Tigrini, A., Verdini, F., Al-Timemy, A. H., Fioretti, S., Burattini, L., & Mengarelli, A. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3364976 · Cited by 46
“Retroreflective markers were positioned following a full body kinematic protocol [51], which can produce reliable kinematic quantities in the sagittal plane utilizing a minimal number of markers.”
MethodEffects of Chronic Ankle Instability on Energy Dissipation in the Lower Extremity
Terada, M., Pfile, K. R., Pietrosimone, B. G., & Gribble, P. A. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829a3d0b · Cited by 46
Pham, M. H., Elshehabi, M., Haertner, L., Heger, T., Hobert, M. A., Faber, G. S., Salkovic, D., Ferreira, J. J., Berg, D., Sánchez‐Ferro, Á., et al. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00135 · Cited by 47
“N (females) 20 (10) 13 (6) Age (years) 66 (9) 60 (10)”
Winiarski, S., Pietraszewska, J., & Pietraszewski, B. (2019) · BioMed Research International · doi:10.1155/2019/9232430 · Cited by 46
“The standard Davis protocol (Newington model applied in the Plug-in Gait model of the BTS system) was used to determine characteristic spots on the bodies of participants [18].”
MethodMun, F., Suh, S. W., Park, H.-J., & Choi, A. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0041-5 · Cited by 45
“The anatomical reference system of upper torso and pelvis segments, and the location of each hip joint were defined by the methods used in previous studies [22–25].”
Loss of fractal gait harmony in Parkinson’s Disease
Iosa, M., Morone, G., Fusco, A., Marchetti, F., Caltagirone, C., Paolucci, S., & Peppe, A. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.016 · Cited by 45
“Six video cameras with a sampling rate of 50 Hz recorded the 3D coordinates of 23 retroreflective markers on the subjects’ skin located in accordance with Davis protocol for human movement analysis (Davis et al., 1991).”
Does First Ray Amputation in Diabetic Patients Influence Gait and Quality of Life?
Aprile, I. G., Galli, M., Pitocco, D., Sipio, E. D., Simbolotti, C., Germanotta, M., Bordieri, C., Padua, L., & Ferrarin, M. (2017) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2017.07.015 · Cited by 45
Mueske, N. M., Vandenberg, C. D., Pace, J. L., Katzel, M. J., Zaslow, T. L., Padilla, R. A., & Wren, T. A. L. (2018) · The Knee · doi:10.1016/j.knee.2018.09.005 · Cited by 45
Age-Related Adaptations of Lower Limb Intersegmental Coordination During Walking
Gueugnon, M., Stapley, P. J., Gouteron, A., Lecland, C., Morisset, C., Casillas, J.-M., Ornetti, P., & Laroche, D. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00173 · Cited by 45
Shih, Y. C., Chau, M. M., Arendt, E. A., & Novacheck, T. F. (2019) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.18.01115 · Cited by 45
Bernetti, A., Agostini, F., Alviti, F., Giordan, N., Martella, F., Santilli, V., Paoloni, M., & Mangone, M. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.673988 · Cited by 46
“The GAIT approach is a non-invasive method to measure body kinematics and kinetics: patients were requested to walk at a self-selected speed along a 10 m level surface after applying on their knee several retroreflective spherical markers to determine the joint centers and segment axis (Davis protocol) (Davis et al.,…”
MethodDoes the anterior approach for total hip arthroplasty better restore stair climbing gait mechanics?
Lamontagne, M., Varin, D., & Beaulé, P. E. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.21392 · Cited by 45
“Anthropometric measurements (height, weight, and leg length) were used to measure the hip joint center location with a commonly used regression technique.(19) The lower body was modeled as a rigid linked body, as previously described.”
MethodMotion-analysis studies of transtibial prosthesis users: a systematic review
Rusaw, D. F., & Ramstrand, N. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364610393060 · Cited by 45
Bonnefoy‐Mazure, A., Turcot, K., Kaelin, A., Coulon, G. D., & Armand, S. (2012) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2012.09.005 · Cited by 47
Celletti, C., Galli, M., Cimolin, V., Castori, M., Albertini, G., & Camerota, F. (2012) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2012.06.018 · Cited by 45
Vahdati, A., Walscharts, S., Jonkers, I., García‐Aznar, J. M., Sloten, J. V., & van Lenthe, H. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.11.015 · Cited by 45
“During subject's walking, reflective markers (Davis et al., 1991) tracked the motion of the subject while two AMTI™ (Advanced Mechanical Technology Inc., Watertown, MA, USA) force plates measured the ground contact force.”
BackgroundThe stroke-related effects of hip flexion fatigue on over ground walking
Rybar, M. M., Walker, E. R., Kuhnen, H. R., Ouellette, D. R., Barillas, R. B., Hunter, S. K., & Hyngstrom, A. S. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.01.012 · Cited by 45
Gait characteristics and functional assessment of children with Type I Osteogenesis Imperfecta
Graf, A. N., Hassani, S., Krzak, J. J., Caudill, A. K., Flanagan, A., Bajorunaite, R., Harris, G. E., & Smith, P. A. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20871 · Cited by 45
Lower-extremity biomechanics during forward and lateral stepping activities in older adults
Wang, M., Flanagan, S. P., Song, J., Greendale, G. A., & Salem, G. J. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(02)00204-8 · Cited by 45
“Three-dimensional kinematics were quantified using methods described by Kadaba et al. (1990) and Davis et al. (1991).”
MethodAssi, A., Sauret, C., Massaad, A., Bakouny, Z., Pillet, H., Skalli, W., & Ghanem, I. B. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.04.028 · Cited by 45
“This could be due to the fact that the regression equation used by the Davis method, which was computed from adult cadavers [7], is inadequate for use in children.”
MethodStief, F., Schmidt, A., van Drongelen, S., Lenarz, K., Froemel, D., Tarhan, T., Lutz, F., & Meurer, A. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.23886 · Cited by 45
Trunk and center of mass movements during gait in children with juvenile idiopathic arthritis
Broström, E. W., Örtqvist, M., Haglund‐Åkerlind, Y., Hagelberg, S., & Gutierrez-Farewik, E. M. (2007) · Human Movement Science · doi:10.1016/j.humov.2007.01.007 · Cited by 44
Aksenov, A. Y., Heath, G. H., Klishkovskaia, T. A., & Игоревна, Д. Т. (2019) · Genij Ortopedii · doi:10.18019/1028-4427-2019-25-1-102-110 · Cited by 45
Marchis, C. D., Ranaldi, S., Varrecchia, T., Serrao, M., Castiglia, S. F., Tatarelli, A., Ranavolo, A., Draicchio, F., Lacquaniti, F., & Conforto, S. (2022) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2022.804746 · Cited by 44
“A six-infrared camera optoelectronic motion analysis system (SMART-DX 6000 System, BTS, Milan, Italy) was used, with passive spherical markers placed according to a modified Davis’ protocol (47).”
MethodKannape, O. A., Barré, A., Aminian, K., & Blanke, O. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085560 · Cited by 47
McClelland, J. A., Feller, J. A., Menz, H. B., & Webster, K. E. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.03.026 · Cited by 44
Muscle Activation during Gait in Children with Duchenne Muscular Dystrophy
Ropars, J., Lempereur, M., Vuillerot, C., Tiffreau, V., Peudenier, S., Cuisset, J., Péréon, Y., Leboeuf, F., Delporte, L., Delpierre, Y., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0161938 · Cited by 44
Drużbicki, M., Guzik, A., Przysada, G., Kwołek, A., Brzozowska-Magoń, A., & Sobolewski, M. (2016) · Medical Science Monitor · doi:10.12659/msm.898420 · Cited by 44
“Reference markers were placed according to the internal protocol of the system (Helen Hayes (Davis) Marker Placement) on the sacrum, pelvis (anterior posterior iliac spine), femur (lateral epicondyle, greater trochanter and in lower 1/3 of the shank), fibula (lateral malleolus, lateral condyle and in lower 1/3 of the…”
MethodTabard-Fougère, A., Rose-Dulcina, K., Pittet, V., Dayer, R., Vuillerme, N., & Armand, S. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.026 · Cited by 44
Goffredo, M., Iacovelli, C., Russo, E. F., Pournajaf, S., Blasi, C. D., Galafate, D., Pellicciari, L., Agosti, M., Filoni, S., Aprile, I. G., et al. (2019) · Applied Sciences · doi:10.3390/app9132627 · Cited by 44
“The Davis heel protocol, which includes 22 retro-reflective markers, was employed [34], and anthropometric data were collected.”
Cricket Fast Bowling Technique and Lumbar Bone Stress Injury
Alway, P., Felton, P., Brooke-Wavell, K. S. F., Peirce, N. S., & King, M. A. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002512 · Cited by 44
“The markers placed over the left and right anterior and posterior superior iliac spine were used to calculate the hip joint centers (24), whereas the midpoint of the posterior superior iliac spine markers defined the lumbopelvic junction (21).”
MethodUpper Body Kinematics in Patients with Cerebellar Ataxia
Conte, C., Pierelli, F., Casali, C., Ranavolo, A., Draicchio, F., Martino, G., Harfoush, M., Padua, L., Coppola, G., Sandrini, G., et al. (2014) · The Cerebellum · doi:10.1007/s12311-014-0586-z · Cited by 44
“Twenty-two markers were placed on anatomical landmarks in accordance with validated biomechanical model [15] and using the anthropometric data of Winter [16].”
MethodRange of motion and repeatability of knee kinematics for 11 clinically relevant motor tasks
Desloovere, K., Wong, P. D., Swings, L., Callewaert, B., Vandenneucker, H., & Leardini, A. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.08.010 · Cited by 46
“determined the 3D trajectories of 23 passive retro-reflective markers (14-mm diameter), located on the lower limbs, pelvis, and trunk (Total body Plug-in-Gait marker set [15,16,27] with Knee Alignment Device, KAD [28], Vicon, Oxford, UK).”
BackgroundInfluence of the 3D Inverse Dynamic Method on the Joint Forces and Moments During Gait
Dumas, R., Nicol, E., & Chèze, L. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2768114 · Cited by 44
von Porat, A., Henriksson, M., Holmström, E., & Roos, E. M. (2007) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-8-35 · Cited by 44
“Calculation methods and model assumptions were as described [40-42].”
MethodThe influence of gait speed on co-activation in unilateral spastic cerebral palsy children
Gross, R., Leboeuf, F., Hardouin, J.-B., Lempereur, M., Perrouin-Verbe, B., Rémy‐Néris, O., & Brochard, S. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.01.002 · Cited by 44
Differences in Gait Across the Menstrual Cycle and Their Attractiveness to Men
Provost, M. P., Quinsey, V. L., & Troje, N. F. (2007) · Archives of Sexual Behavior · doi:10.1007/s10508-007-9219-7 · Cited by 44
“We also placed additional markers (for a total of 41) directly on their skin, using a modified version of the Helen Hayes marker set ( Davis, Ounpuu, Tyburski, & Gage, 1991 ).”
MethodPostural inflexibility in PD: Does it affect compensatory stepping?
Smulders, K., Esselink, R. A. J., de Swart, B. J., Geurts, A. C. H., Bloem, B. R., & Weerdesteyn, V. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.10.003 · Cited by 44
“Reflective markers were placed at the legs and trunk according to the Vicon Plug-in-Gait model [21].”
MethodDewan, B. M., James, C. R., Kumar, N. A., & Sawyer, S. F. (2019) · BioMed Research International · doi:10.1155/2019/8185710 · Cited by 44
“*e study implemented Vicon’s PiG model, the scientific basis of which is previously validated [32, 33], to compute whole body COM position providing a direct measure of balance function.”
MethodGait analysis in children and uncertainty assessment for Davis protocol and Gillette Gait Index
Assi, A., Ghanem, I. B., Lavaste, F., & Skalli, W. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.02.011 · Cited by 44
“This study evaluated the uncertainty and repeatability of the GGI and kinematics using Davis model [6] and Helen Hayesmarker set for young subjects in gait analysis.”
MethodInfluentialQuantification of Pelvic Soft Tissue Artifact in Multiple Static Positions
Hara, R., Sangeux, M., Baker, R., & McGinley, J. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2013.10.001 · Cited by 43
“The pelvic segment and its coordinate system were defined according to the Davis model [2] and according to VICON’s PiG implementation, which describes x, y, and z axis in direction of anterior/posterior, medial/lateral, and superior/inferior, respectively.”
MethodInfluentialMcMulkin, M. L., Gordon, A. B., Caskey, P. M., Tompkins, B. J., & Baird, G. O. (2015) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0000000000000465 · Cited by 43
Lam, M.-H., Fong, D. T.-P., Yung, P. S., Ho, E. P.-Y., Fung, K.-Y., & Chan, K. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510394430 · Cited by 43
“With the anthropometric measurements, knee joint kinematics was then calculated.(6) All calculations were conducted using a self-compiled program (MathWorks, Natick, Massachusetts).”
MethodAn optimal control approach to reconstruct human gait dynamics from kinematic data
Felis, M. L., Mombaur, K., & Berthoz, A. (2015) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2015.7363490 · Cited by 43
“[5] only describes the computation for the lower-limb kinematics, however for the upper-body we were not able to find corresponding references.”
BackgroundMethodSHIBATA, S., Takemura, M., & Miyakawa, S. (2018) · Physical Therapy Research · doi:10.1298/ptr.e9938 · Cited by 44
Ward, R. E., Yan, A. F., Orishimo, K. F., Kremenic, I. J., Hagins, M., Liederbach, M., Hiller, C. E., & Pappas, E. (2018) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13309 · Cited by 43
The effects of dual tasks on gait in children with cerebral palsy
Carcreff, L., Fluss, J., Allali, G., Valenza, N., Aminian, K., Newman, C. J., & Armand, S. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.02.014 · Cited by 43
Landing Kinematics and Isometric Hip Strength of Individuals With Chronic Ankle Instability
McCann, R. S., Terada, M., Kosik, K. B., & Gribble, P. A. (2019) · Foot & Ankle International · doi:10.1177/1071100719846085 · Cited by 44
Metadata
- Authors
- Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R.
- Affiliations
- Newmarket Hospital (GB)
- Corresponding author
- Davis, Roy B.
- Venue
- Human Movement Science
- Publisher
- Elsevier BV
- Published
- 1991-10
- Volume
- 10
- Issue
- 5
- Pages
- 575-587
- ISSN
- 0167-9457 (ISSN-L)
- OpenAlex
- W2049223406
- Cited by
- 3,086
- References
- 13
- Citations by year
- 2026: 121 · 2025: 162 · 2024: 153 · 2023: 157 · 2022: 166 · 2021: 177 · 2020: 179 · 2019: 175 · 2018: 187 · 2017: 165 · 2016: 167 · 2015: 155 · 2014: 151 · 2013: 142 · 2012: 126
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Human Movement Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- gait analysis, motion capture, retroreflective markers, joint kinetics, force plate, electromyography, data reduction, human locomotion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.