Tetanus toxoid and synthetic malaria antigen containing poly(lactide)/poly(lactide-co-glycolide) microspheres: importance of polymer degradation and antigen release for immune response
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krevelen, D. W. V. (1990) · Cited by 4,491
Controlled Delivery Systems for Proteins Based on Poly(Lactic/Glycolic Acid) Microspheres
Cohen, S., Yoshioka, T., Lucarelli, M., Hwang, L. H., & Langer, R. (1991) · Pharmaceutical Research · doi:10.1023/a:1015841715384 · Cited by 843
Eldridge, J. H., Hammond, C. J., Meulbroek, J. A., Staas, J. K., Gilley, R. M., & Tice, T. R. (1990) · Journal of Controlled Release · doi:10.1016/0168-3659(90)90133-e · Cited by 689
Effect of the size and surface charge of polymer microspheres on their phagocytosis by macrophage
Tabata, Y., & Ikada, Y. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90033-6 · Cited by 538
Degradation of poly (D,L-lactic acid) microspheres: Effect of molecular weight
Park, T. G. (1994) · Journal of Controlled Release · doi:10.1016/0168-3659(94)90263-1 · Cited by 359
Biodegradable Polymers and Plastics
(2003) · Springer eBooks · doi:10.1007/978-1-4419-9240-6 · Cited by 337
Biodegradable microspheres as controlled-release tetanus toxoid delivery systems
Alonso, M. J., Gupta, R. K., Min, C., Siber, G. R., & Langer, R. (1994) · Vaccine · doi:10.1016/0264-410x(94)90092-2 · Cited by 313
More about the degradation of LA/GA-derived matrices in aqueous media
Vert, M., Li, S., & Garreau, H. (1991) · Journal of Controlled Release · doi:10.1016/0168-3659(91)90027-b · Cited by 295
Biodegradable Polymers and Plastics
(2004) · Chemistry International -- Newsmagazine for IUPAC · doi:10.1515/ci.2004.26.2.30b · Cited by 293
Park, T. G., Lu, W., & Crotts, G. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(94)00084-8 · Cited by 255
Cited by
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
“In this study, Gander and colleagues examined the effect of polymer degradation time, microsphere size, antigen release kinetics and immunological responses in mice [74].”
BackgroundBiodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.004 · Cited by 814
Engineering synthetic vaccines using cues from natural immunity
Irvine, D. J., Swartz, M. A., & Szeto, G. L. (2013) · Nature Materials · doi:10.1038/nmat3775 · Cited by 594
Oyewumi, M. O., Kumar, A., & Cui, Z. (2010) · Expert Review of Vaccines · doi:10.1586/erv.10.89 · Cited by 547
Tam, H. H., Melo, M. B., Kang, M., Pelet, J. M., Ruda, V. M., Foley, M. H., Hu, J. K., Kumari, S., Crampton, J., Baldeon, A. D., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1606050113 · Cited by 425
Controlled drug delivery in tissue engineering
Biondi, M., Ungaro, F., Quaglia, F., & Netti, P. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.038 · Cited by 412
Designing spatial and temporal control of vaccine responses
Roth, G. A., Picece, V. C. T. M., Ou, B. S., Luo, W., Pulendran, B., & Appel, E. A. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00372-2 · Cited by 316
Formulation aspects of biodegradable polymeric microspheres for antigen delivery
TAMBER, H., JOHANSEN, P., MERKLE, H., & GANDER, B. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.09.002 · Cited by 316
Self-citationShape and size-dependent immune response to antigen-carrying nanoparticles
Kumar, S., Anselmo, A. C., Banerjee, A., Zakrewsky, M., & Mitragotri, S. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.09.069 · Cited by 307
Gutierro, I., Hernández, R. M., Igartua, M., Gascón, A. R., & Pedraz, J. L. (2002) · Vaccine · doi:10.1016/s0264-410x(02)00435-8 · Cited by 292
Thiele, L., Rothen-Rutishauser, B., Jilek, S., Wunderli-Allenspach, H., Merkle, H. P., & Walter, E. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00412-6 · Cited by 281
Self-citationSchlosser, E., Mueller, M., Fischer, S., Basta, S., Busch, D. H., Gander, B., & Groettrup, M. (2008) · Vaccine · doi:10.1016/j.vaccine.2008.01.030 · Cited by 262
Self-citationWalter, E., Moelling, K., Pavlovic, J., & Merkle, H. P. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00151-0 · Cited by 257
Self-citationParticulate formulations for the delivery of poly(I:C) as vaccine adjuvant
Hafner, A. M., Corthésy, B., & Merkle, H. P. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.013 · Cited by 247
“Three processes were commonly used for the preparation of antigen-loaded PLGA microspheres: (i) phase separation, frequently also called coacervation [158], (ii) spray-drying [158,159] and (iii) solvent extraction/evaporation [160].”
MethodSelf-citationThomas, C., Rawat, A., Hope-Weeks, L., & Ahsan, F. (2011) · Molecular Pharmaceutics · doi:10.1021/mp100255c · Cited by 241
Walter, E., Dreher, D., Kok, M., Thiele, L., Kiama, S. G., Gehr, P., & Merkle, H. P. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00413-8 · Cited by 230
Self-citationPreparation of functional nanostructured particles by spray drying
Okuyama, K., Abdullah, M., Wuled Lenggoro, I., & Iskandar, F. (2006) · Advanced Powder Technology · doi:10.1163/156855206778917733 · Cited by 215
pH and Osmotic Pressure Inside Biodegradable Microspheres During Erosion1
Brunner, A., Mäder, K., & Göpferich, A. (1999) · Pharmaceutical Research · doi:10.1023/a:1018822002353 · Cited by 213
Revisiting PLA/PLGA microspheres: an analysis of their potential in parenteral vaccination
Johansen, P. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00079-5 · Cited by 210
Defining and designing polymers and hydrogels for neural tissue engineering
Aurand, E. R., Lampe, K. J., & Bjugstad, K. B. (2012) · Neuroscience Research · doi:10.1016/j.neures.2011.12.005 · Cited by 206
Park, T. G., Yong Lee, H., & Sung Nam, Y. (1998) · Journal of Controlled Release · doi:10.1016/s0168-3659(98)00050-9 · Cited by 198
Biodegradable polymers in drug delivery and oral vaccination
Jana, P., Shyam, M., Singh, S., Jayaprakash, V., & Dev, A. (2021) · European Polymer Journal · doi:10.1016/j.eurpolymj.2020.110155 · Cited by 178
Audran, R., Peter, K., Dannull, J., Men, Y., Scandella, E., Groettrup, M., Gander, B., & Corradin, G. (2003) · Vaccine · doi:10.1016/s0264-410x(02)00521-2 · Cited by 168
Self-citationPrior, S., Gander, B., Blarer, N., Merkle, H. P., Subirá, M. L., Irache, J. M., & Gamazo, C. (2002) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00218-4 · Cited by 138
Self-citation“Programmed polymeric devices” for pulsed drug delivery
Stubbe, B. G., De Smedt, S. C., & Demeester, J. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000045223.45400.01 · Cited by 84
Immunogenicity of single-dose diphtheria vaccines based on PLA/PLGA microspheres in guinea pigs
Johansen, P., Moon, L., Tamber, H., Merkle, H. P., Gander, B., & Sesardic, D. (1999) · Vaccine · doi:10.1016/s0264-410x(99)00191-7 · Cited by 71
Self-citationOral Immunization with Helicobacter pylori‐Loaded Poly( d, l‐Lactide‐Co‐Glycolide) Nanoparticles
Kim, S., Doh, H., Jang, M., Ha, Y., Chung, S., & Park, H. (1999) · Helicobacter · doi:10.1046/j.1523-5378.1999.09046.x · Cited by 65
Luzardo-Alvarez, A., Blarer, N., Peter, K., Romero, J. F., Reymond, C., Corradin, G., & Gander, B. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.09.015 · Cited by 59
Self-citationFelder, C. B., Blanco-Príeto, M. J., Heizmann, J., Merkle, H. P., & Gander, B. (2003) · Journal of Microencapsulation · doi:10.3109/02652040309178346 · Cited by 55
Self-citationBiodegradable PLGA Particles for Improved Systemic and Mucosal Treatment of Type I Allergy
Schöll, I., Kopp, T., Bohle, B., & Jensen-Jarolim, E. (2006) · Immunology and Allergy Clinics of North America · doi:10.1016/j.iac.2006.02.007 · Cited by 40
“First, the bioerosion rates and thereby the release kinetics can be tailored to the needs of the respective application [34].”
BackgroundPeyre, M., Sesardic, D., Merkle, H. P., Gander, B., & Johansen, P. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10361 · Cited by 36
Self-citationIgartua, M., Hernández, R. M., Gutierro, I., Gascón, A. R., & Pedraz, J. L. (2001) · Pharmaceutical Development and Technology · doi:10.1081/pdt-120000299 · Cited by 12
Metadata
- Authors
- Thomasin, C., Corradin, G., Men, Y., Merkle, H. P., & Gander, B.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 1996-08
- Volume
- 41
- Issue
- 1-2
- Pages
- 131-145
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2032247822
- Cited by
- 188
- References
- 36
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.