The development and application of FET-based biosensors
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bousse, L., De Rooij, N. F., & Bergveld, P. (1983) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1983.21284 · Cited by 574 · cited 1×
“Therefore this parameter has to be investigated in more detail (Bousse et al ., 1983) .”
MethodSelf-citationThe operation of an ISFET as an electronic device
Bergveld, P. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80004-2 · Cited by 179 · cited 3×
“In order to obtain a stable ISFET operation, the ISFET is always applied in a feedback circuit (Bergveld, 1981) .”
BackgroundMethodSelf-citationThe history of chemically sensitive semiconductor devices
Bergveld, P., & de Rooij, N. F. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80003-0 · Cited by 30 · cited 1×
“A very short description of the operation of an ISI-ET can be ma e by comparing it with its purely electronic analogue, the MOSFET (metal oxide semiconductor field effect transistor) (Bergveld & de Rooij, 1981) .”
Self-citationHydrogel basedin vivo reference electrode catheter
Margules, G. S., Hunter, C. M., & MacGregor, D. C. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446400 · Cited by 21
Sensors of biological organisms — biological transducers
Stieve, H. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85083-5 · Cited by 21 · cited 1×
“Personally, the author would like to compare biosensors with ON natural type of biosensors, which are as old as the living organisms or earth, namely the bioreceptors (Stieve, 1983) .”
Background
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Biosensors and Microfluidic Biosensors: From Fabrication to Application
Kulkarni, M. B., Ayachit, N. H., & Aminabhavi, T. M. (2022) · Biosensors · doi:10.3390/bios12070543 · Cited by 281
Waleed Shinwari, M., Jamal Deen, M., & Landheer, D. (2007) · Microelectronics Reliability · doi:10.1016/j.microrel.2006.10.003 · Cited by 268
Dielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor
Kannan, N., & Kumar, M. J. (2013) · IEEE Electron Device Letters · doi:10.1109/led.2013.2283858 · Cited by 161
“THE application of field effect transistor (FET) as a biosensor for label-free detection of charged biomolecules has seen significant usage [1]–[3].”
BackgroundChakraborty, A., & Sarkar, A. (2017) · Journal of Computational Electronics · doi:10.1007/s10825-017-0999-2 · Cited by 94
Sharma, S., Nath, V., Deswal, S. S., & Gupta, R. S. (2022) · Microelectronics Journal · doi:10.1016/j.mejo.2022.105599 · Cited by 31
Metadata
- Authors
- Bergveld, P.
- Venue
- Biosensors
- Publisher
- Elsevier BV
- Published
- 1986-01
- Volume
- 2
- Issue
- 1
- Pages
- 15-33
- ISSN
- 0265-928X (ISSN-L)
- OpenAlex
- W2128912813
- Cited by
- 207
- References
- 5
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.