Drug release from microdisperse systems: a critical review
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Higuchi, T. (1963) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600521210 · Cited by 4,884
Ritger, P. L., & Peppas, N. A. (1987) · Journal of Controlled Release · doi:10.1016/0168-3659(87)90035-6 · Cited by 4,064
Rate of Release of Medicaments from Ointment Bases Containing Drugs in Suspension
Higuchi, T. (1961) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600501018 · Cited by 2,262
Kinetics of drug release from hydrogel matrices
Lee, P. I. (1985) · Journal of Controlled Release · doi:10.1016/0168-3659(85)90051-3 · Cited by 433
Bodmeier, R., & McGinity, J. W. (1987) · Pharmaceutical Research · doi:10.1023/a:1016419303727 · Cited by 198
Magnetic Microspheres: Synthesis of a Novel Parenteral Drug Carrier
Widder, K., Flouret, G., & Senyei, A. (1979) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600680124 · Cited by 196
Analysis of non-fickian transport in polymers using simplified exponential expressions
Sinclair, G. W., & Peppas, N. A. (1984) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)83223-8 · Cited by 167
Preparation and evaluation in vitro of polylactic acid microspheres containing local anesthetics.
Wakiyama, N., Juni, K., & Nakano, M. (1981) · Chemical and Pharmaceutical Bulletin · doi:10.1248/cpb.29.3363 · Cited by 138
Washington, C. (1989) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(89)90062-8 · Cited by 112
Self-citationHarland, R. S., Dubernet, C., Benoît, J., & Peppas, N. A. (1988) · Journal of Controlled Release · doi:10.1016/0168-3659(88)90053-3 · Cited by 89
Cited by
Biodegradable polymeric nanoparticles as drug delivery devices
Soppimath, K. S., Aminabhavi, T. M., Kulkarni, A. R., & Rudzinski, W. E. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(00)00339-4 · Cited by 3,549
Chitosan—A versatile semi-synthetic polymer in biomedical applications
Dash, M., Chiellini, F., Ottenbrite, R. M., & Chiellini, E. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.02.001 · Cited by 2,903
Recent advances on chitosan-based micro- and nanoparticles in drug delivery
Agnihotri, S. A., Mallikarjuna, N. N., & Aminabhavi, T. M. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.08.010 · Cited by 2,586
Mathematical Modeling of Release Kinetics from Supramolecular Drug Delivery Systems
Mircioiu, C., Voicu, V., Anuta, V., Tudose, A., Celia, C., Paolino, D., Fresta, M., Sandulovici, R., & Mircioiu, I. (2019) · Pharmaceutics · doi:10.3390/pharmaceutics11030140 · Cited by 480
Chen, H., Kim, S., Li, L., Wang, S., Park, K., & Cheng, J.-X. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707046105 · Cited by 394
“The core composed of hydrophobic chains is expected to regulate the retention and the release of loaded drug molecules on an appropriate time scale (6–8).”
Zhuang, C.-Y., Li, N., Wang, M., Zhang, X.-N., Pan, W.-S., Peng, J.-J., Pan, Y.-S., & Tang, X. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.05.005 · Cited by 318
Benita, S., & Levy, M. Y. (1993) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600821102 · Cited by 311
Modi, S., & Anderson, B. D. (2013) · Molecular Pharmaceutics · doi:10.1021/mp400154a · Cited by 307
Larsen, C., Østergaard, J., Larsen, S. W., Jensen, H., Jacobsen, S., Lindegaard, C., & Andersen, P. H. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21346 · Cited by 301
Mechanisms by which cyclodextrins modify drug release from polymeric drug delivery systems
Bibby, D. C., Davies, N. M., & Tucker, I. G. (2000) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(00)00335-5 · Cited by 298
Methods to Assess in Vitro Drug Release from Injectable Polymeric Particulate Systems
D'Souza, S. S., & DeLuca, P. P. (2006) · Pharmaceutical Research · doi:10.1007/s11095-005-9397-8 · Cited by 288
Sustained-release from nanocarriers: a review
Natarajan, J. V., Nugraha, C., Ng, X. W., & Venkatraman, S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.029 · Cited by 285
Magenheim, B., Levy, M. Y., & Benita, S. (1993) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(93)90015-8 · Cited by 250
Injectable Lipid Emulsions—Advancements, Opportunities and Challenges
Hippalgaonkar, K., Majumdar, S., & Kansara, V. (2010) · AAPS PharmSciTech · doi:10.1208/s12249-010-9526-5 · Cited by 236
Predicting drug release kinetics from nanocarriers inside dialysis bags
Yu, M., Yuan, W., Li, D., Schwendeman, A., & Schwendeman, S. P. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.09.016 · Cited by 232
“In dialysis settings, the sink condition is assumed to be achieved by having a large volume of release media in the receiver compartment which is 10–20 times higher than the volume required for the saturated drug solution [17].”
BackgroundLocatelli, E., & Comes Franchini, M. (2012) · Journal of Nanoparticle Research · doi:10.1007/s11051-012-1316-4 · Cited by 229
“…the in vitro release: most of this involved typical purification procedures like the use of artificial or biological membranes, dialysis, ultrafiltration, or ultracentrifugation techniques but nowadays difficulties in a good determination of the release profile are still present (Washington 1990).”
MethodDrug release from nanomedicines: selection of appropriate encapsulation and release methodology
Wallace, S. J., Li, J., Nation, R. L., & Boyd, B. J. (2012) · Drug Delivery and Translational Research · doi:10.1007/s13346-012-0064-4 · Cited by 217
“The true release rate must be deconvoluted from the kinetics of drug diffusion across the membrane, which requires a priori knowledge of the appropriate “free” concentration to enable an appropriate control experiment to be conducted [1].”
InfluentialAllémann, E., Leroux, J.-C., Gurny, R., & Doelker, E. (1993) · Pharmaceutical Research · doi:10.1023/a:1018970030327 · Cited by 212
Effects of crystalline microstructure on drug release behavior of poly(ε-caprolactone) microspheres
Jeong, J.-C., Lee, J., & Cho, K. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(03)00367-5 · Cited by 209
Chorny, M., Fishbein, I., Yellen, B. B., Alferiev, I. S., Bakay, M., Ganta, S., Adamo, R., Amiji, M., Friedman, G., & Levy, R. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909506107 · Cited by 197
Artificial intelligence to bring nanomedicine to life
Serov, N., & Vinogradov, V. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114194 · Cited by 189
Kim, Y. I., Fluckiger, L., Hoffman, M., Lartaud‐Idjouadiene, I., Atkinson, J., & Maincent, T. (1997) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0700910 · Cited by 61
“The main problem with the dialysis bag technique is that it is not a rapid sink method (Washington, 1989; 1990).”
Method
Metadata
- Authors
- Washington, C.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 1990-01
- Volume
- 58
- Issue
- 1
- Pages
- 1-12
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2019796793
- Cited by
- 314
- References
- 16
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.