An automated intelligent diagnostic system for the interpretation of umbilical artery Doppler velocimetry
Abstract
The objective is to develop an automated intelligent diagnostic system for the interpretation of umbilical artery velocity waveforms. An ultrasound instrument with pulsed-wave Doppler is connected to a microcomputer by means of a frame grabber. After data acquisition, umbilical Doppler velocimetry is handled as a pattern recognition (feature extraction and classification) and decision-making problem. Automated image processing (enhancement, smoothing/ thresholding and edge detection) and analysis are used for feature extraction. Six waveform indices obtained by feature extraction are used as input layer to vector quantization which classifies waveforms into six groups. A clinical decision is assigned to each group by the medical expert. Our system is trained by 278 and 380 waveform images of 94 normal and 157 high risk pregnancies, respectively. The system was tested with 193 and 61 images of normal and risky pregnancies; it was demonstrated that sensitivity and specificity of the system are 54.1% and 80.3%, respectively.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Beksaç et al. and Baykal et al. presented an automated diagnostic, interpretation, and classification method to analyze umbilical artery blood flow Doppler US images.
“In the earliest studies included in this review, Beksaç et al. and Baykal et al. presented an automated diagnostic, interpretation, and classification method to analyze umbilical artery blood flow Doppler US images [124,125,126].”
Cites
An Algorithm for Vector Quantizer Design
Linde, Y., Buzo, A., & Gray, R. (1980) · IEEE Transactions on Communications · doi:10.1109/tcom.1980.1094577 · Cited by 7,201 · see citing works
Non-invasive measurement of human fetal circulation using ultrasound: a new method.
Fitzgerald, D. E., & Drumm, J. (1977) · BMJ · doi:10.1136/bmj.2.6100.1450 · Cited by 398 · see citing works
Wladimiroff, J. W., van den Wijngaard, J. A. G. W., Degani, S., Noordam, M. J., van Eyck, J., & Tonge, H. M. (1987) · PubMed · Cited by 348 · see citing works
Bilardo, C. M., Nicolaides, K. H., & Campbell, S. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90833-s · Cited by 280 · see citing works
Umbilical artery velocity waveforms and intrauterine growth retardation
Fleischer, A., Schulman, H., Farmakides, G., Bracero, L. A., Blattner, P., & Randolph, G. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90278-9 · Cited by 268 · see citing works
Umbilical artery blood flow characteristics in normal and growth‐retarded fetuses.
EKSKINE, R. L. A., & Ritchie, J. W. K. (1985) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1985.tb01399.x · Cited by 212 · see citing works
The significance of absent end-diastolic velocity in umbilical artery velocity waveforms
Rochelson, B. L., Schulman, H., Farmakides, G., Bracero, L. A., Ducey, J., Fleischer, A., Penny, B., & Winter, D. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(87)90147-5 · Cited by 196 · see citing works
UMBILICAL ARTERY FLOW VELOCITY WAVEFORMS IN HIGH-RISK PREGNANCY
Trudinger, B. J., Giles, W. B., Cook, C., Connelly, A., & Thompson, R. (1987) · The Lancet · doi:10.1016/s0140-6736(87)90003-1 · Cited by 178 · see citing works
Doppler flow velocity waveform analysis in high risk pregnancies: a randomized controlled trial
Newnham, J. P., OʼDEA, M. R.-A., Reid, K. P., & Diepeveen, D. (1991) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1991.tb15332.x · Cited by 84 · see citing works
A critical appraisal of fetal surveillance
Owen, P., & Patel, N. B. (1994) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(94)90057-4 · Cited by 81 · see citing works
Critical Appraisal of Fetal Surveillance
van Geijn, H. P., & Copray, F. J. A. (1994) · Medical Entomology and Zoology · Cited by 64 · see citing works
Omtzigt, A., Reuwer, P. J. H. M., & Bruinse, H. W. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(94)70240-3 · Cited by 64 · see citing works
Brar, H. S., Medearis, A. L., DeVore, G. R., & Platt, L. D. (1988) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(88)80178-9 · Cited by 35 · see citing works
Fairlie, F., Moretti, M. L., Walker, J. J., & Sibai, B. M. (1991) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(91)90590-n · Cited by 35 · see citing works
Anteby, E. Y., Tadmor, O. P., Revel, A., & Yagel, S. (1994) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(94)90244-5 · Cited by 27 · see citing works
Beksaç, M. S., Başaran, F., Eskiizmirliler, S., Erkmen, A. M., & Yörükan, S. (1996) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0301-2115(95)02256-2 · Cited by 23 · see citing works
Self-citationDoppler Velocimetry in Obstetrics
Maulik, D., Yarlagadda, P. K. D. V., & Downing, G. J. (1990) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/s0889-8545(21)00471-x · Cited by 23 · see citing works
Chan, F.-Y., Lam, C., Lam, Y. H., To, W. K., Pun, T. C., & Lee, C. P. (1994) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(94)90073-6 · Cited by 17 · see citing works
van Vugt, J. M. G. (1991) · Journal of Perinatal Medicine · doi:10.1515/jpme.1991.19.1-2.15 · Cited by 15 · see citing works
Are Blood Flow Velocity Waveforms Related to Umbilical Cord Acid-Base Status in the Human Fetus?
Arduini, D., Rizzo, G., Romaninï, C., & Mancuso, S. (2010) · Gynecologic and Obstetric Investigation · doi:10.1159/000293652 · Cited by 14 · see citing works
Doppler Ultrasonography of the Umbilical Cord in Complicated Pregnancies
BRUNER, J. B., LEVY, D. W., & Arger, P. H. (1993) · Southern Medical Journal · doi:10.1097/00007611-199304000-00009 · Cited by 11 · see citing works
Mori, A., Iwashita, M., & Takeda, Y. (1993) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446650 · Cited by 9 · see citing works
Pattinson, R., Norman, K., & Odendaal, H. J. (1993) · PubMed · Cited by 7 · see citing works
Beksaç, M. S., Önderoğlu, L., Özdemir, K., & Karakaş, Ü. (1991) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(91)90151-a · Cited by 6 · see citing works
Self-citation
Flagged first, then by citations
3 of the 27 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Davidson, L., & Boland, M. R. (2020) · Briefings in Bioinformatics · doi:10.1093/bib/bbaa369 · Cited by 127 · see citing works
Abut, S., Okut, H., & Kallail, K. J. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.122983 · Cited by 58 · see citing works
Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44 · see citing works
Şeker, H., Evans, D. H., Aydın, N., & Yazgan, E. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.945289 · Cited by 36 · see citing works
Image quality in image classification: Design and construction of an image quality database
Yan, S., Sayad, S., & Balke, S. T. (2008) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.10.013 · Cited by 4 · see citing works
Doherty, D. A., JAMES, I. R., & Newnham, J. P. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00574-4 · Cited by 3 · see citing works
ADAPTIVE IMAGE QUALITY IMPROVEMENT WITH BAYESIAN CLASSIFICATION FOR IN-LINE MONITORING
Yan, S. (2008) · TSpace (University of Toronto) · Cited by 2 · see citing works
Application of FFT-Analyzed Umbilical Artery Doppler Signals to Fuzzy Algorithm
Hardalaç, F., Bırı, A., & Sucak, A. (2004) · Journal of Medical Systems · doi:10.1023/b:joms.0000044957.91060.f5
- Authors
- Beksaç, M. S., Egemen, A., izzetoǵlu, K., Ergün, G., & Erkmen, A. M.
- Affiliations
- Hacettepe University (TR)
- Middle East Technical University (TR)
- Corresponding author
- Beksaç, M.Sinan
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 1996-09
- Volume
- 23
- Issue
- 2
- Pages
- 162-167
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W2018090249
- Cited by
- 8
- References
- 27
- Citations by year
- 2023: 2 · 2020: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Journal of Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Keywords
- umbilical artery Doppler, pattern recognition, feature extraction, vector quantization, high-risk pregnancy, fetal growth restriction, clinical decision support, image processing, edge detection, thresholding
- MeSH terms
- Artificial Intelligence, Blood Flow Velocity, Decision Making, Diagnosis, Computer-Assisted, Expert Systems, Female, Gestational Age, Humans, Image Enhancement, Image Processing, Computer-Assisted, Microcomputers, Pattern Recognition, Automated, Pregnancy, Pregnancy Complications, Software, Umbilical Arteries, Pregnancy, High-Risk, Ultrasonography, Doppler, Pulsed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review