Cited by 8Artificial Intelligence in HealthcarePregnancy and preeclampsia studiesMedical Image Segmentation Techniques

An automated intelligent diagnostic system for the interpretation of umbilical artery Doppler velocimetry

Beksaç, M.Sinan, Egemen, Ali, izzetoǵlu, Kurtuluş, Ergün, Gülşah, Erkmen, Aydan M.·1996·European Journal of Radiology

Abstract

The objective is to develop an automated intelligent diagnostic system for the interpretation of umbilical artery velocity waveforms. An ultrasound instrument with pulsed-wave Doppler is connected to a microcomputer by means of a frame grabber. After data acquisition, umbilical Doppler velocimetry is handled as a pattern recognition (feature extraction and classification) and decision-making problem. Automated image processing (enhancement, smoothing/ thresholding and edge detection) and analysis are used for feature extraction. Six waveform indices obtained by feature extraction are used as input layer to vector quantization which classifies waveforms into six groups. A clinical decision is assigned to each group by the medical expert. Our system is trained by 278 and 380 waveform images of 94 normal and 157 high risk pregnancies, respectively. The system was tested with 193 and 61 images of normal and risky pregnancies; it was demonstrated that sensitivity and specificity of the system are 54.1% and 80.3%, respectively.

Integrity signals

Registry

Crossref · 10.1016/0720-048x(96)01067-4

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

3 of the 27 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Beksaç, M. S., Egemen, A., izzetoǵlu, K., Ergün, G., & Erkmen, A. M.
Affiliations
  • Hacettepe University (TR)
  • Middle East Technical University (TR)
Corresponding author
Beksaç, M.Sinan
Venue
European Journal of Radiology
Publisher
Elsevier BV
Published
1996-09
Volume
23
Issue
2
Pages
162-167
ISSN
0720-048X (ISSN-L)
OpenAlex
W2018090249
Cited by
8
References
27
Citations by year
2023: 2 · 2020: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
Keywords
umbilical artery Doppler, pattern recognition, feature extraction, vector quantization, high-risk pregnancy, fetal growth restriction, clinical decision support, image processing, edge detection, thresholding
MeSH terms
Artificial Intelligence, Blood Flow Velocity, Decision Making, Diagnosis, Computer-Assisted, Expert Systems, Female, Gestational Age, Humans, Image Enhancement, Image Processing, Computer-Assisted, Microcomputers, Pattern Recognition, Automated, Pregnancy, Pregnancy Complications, Software, Umbilical Arteries, Pregnancy, High-Risk, Ultrasonography, Doppler, Pulsed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review