Cited by 332Liver Disease Diagnosis and TreatmentAdvanced MRI Techniques and ApplicationsNMR spectroscopy and applications

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Quantification of liver fat using magnetic resonance spectroscopy

Abstract

Localized proton MR spectroscopy using stimulated echoes was used to quantify the liver fat concentration in patients with various degrees of fatty liver due to alcohol abuse. Ten patients underwent a liver biopsy followed by chemical triglyceride estimation of the fatty content. A statistically significant correlation was found between the fat concentration measured in the liver biopsies, and the concentration calculated from the spectroscopic experiments (r = 0.9, p < .001). Quantitative assessment of liver fat concentrations using localized spectroscopy is superior to methods based on differences in relaxation times, and can be used to estimate the fat concentration over the full range of fat content in contrast to the spectroscopic imaging methods. Localized spectroscopy may replace liver biopsy in the diagnosis of diffuse fatty infiltrations, and can be used for follow-up, due to its noninvasive nature.

Overview

Integrity signals

Registry

Crossref · 10.1016/0730-725x(94)92543-7

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 37 references

Research works printed but not linked: 3

  1. Von Rödl, 1985, Die Kernspintomographie zur Untersuchung der Leber und ihrer Erkrankungen, Z. Gastroenterol., 23, 31
  2. Fantazzini, 1987, 1H-NMR in vitro sensitivity to lipid accumulation, Eurospin, 10, 77
  3. Henriksen, 1987, Rekommandation af regime ved perkutan leverbiopsi, Ugeskr. Laeger, 47, 3177

Cited by

Sorted by citations

Items 201–300 of 332

Metadata

Authors
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O.
Affiliations
University of Copenhagen (DK)
Corresponding author
Thomsen, Carsten
Venue
Magnetic Resonance Imaging
Publisher
Elsevier BV
Published
1994-01
Volume
12
Issue
3
Pages
487-495
ISSN
0730-725X (ISSN-L)
OpenAlex
W2093071246
Cited by
332
References
37
Citations by year
2025: 4 · 2024: 4 · 2023: 6 · 2022: 7 · 2021: 4 · 2020: 9 · 2019: 7 · 2018: 9 · 2017: 17 · 2016: 7 · 2015: 15 · 2014: 15 · 2013: 18 · 2012: 17
FWCI
1.37
Type
journal article
Language
en
Open access
closed
Locations
  • Magnetic Resonance Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Hepatology › Liver Disease Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
Keywords
liver fat quantification, 1H NMR, stimulated echo, alcoholic fatty liver, liver biopsy, triglyceride content, non-invasive diagnosis
MeSH terms
Adult, Aged, Biopsy, Fatty Liver, Alcoholic, Female, Humans, Lipids, Liver, Male, Middle Aged, Magnetic Resonance Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review