Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 132 of the 132 references it cites were found in a registry or an index; 16 of the 99 sources its claims cite were checked for support.

Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives

Open access
Podevin, Michael, Fotidis, Ioannis A., Angelidaki, Irini · 2018 · Critical Reviews in Biotechnology

Abstract

emissions. However, due to economic challenges, microalgae bioprocesses have maneuvered towards the simultaneous production of food, feed, fuel, and various high-value chemicals in a biorefinery concept. On-line and in-line monitoring of macromolecules such as lipids, proteins, carbohydrates, and high-value pigments will be more critical to maintain product quality and consistency for downstream processing in a biorefinery to maintain and valorize these markets. The main contribution of this review is to present current and prospective advances of on-line and in-line process analytical technology (PAT), with high-selectivity - the capability of monitoring several analytes simultaneously - in the interest of improving product quality, productivity, and process automation of a microalgal biorefinery. The high-selectivity PAT under consideration are mid-infrared (MIR), near-infrared (NIR), and Raman vibrational spectroscopies. The current review contains a critical assessment of these technologies in the context of recent advances in software and hardware in order to move microalgae production towards process automation through multivariate process control (MVPC) and software sensors trained on "big data". The paper will also include a comprehensive overview of off-line implementations of vibrational spectroscopy in microalgal research as it pertains to spectral interpretation and process automation to aid and motivate development.

Overview

CoChat Summary

TL;DR

This review critically assesses on-line/in-line MIR, NIR, and Raman vibrational spectroscopy as process analytical technology for microalgal biorefineries, emphasizing high-selectivity monitoring of lipids, proteins, carbohydrates, pigments, and contaminants. It concludes MIR/ATR-FTIR is currently most promising for high-selectivity and mixed-culture/contamination prediction, Raman is a growing competitor, and NIR remains cheap and reliable for basic constituents.

Key findings

  • MIR/ATR-FTIR is considered best suited for high-selectivity, species and phenotypic differentiation, and mixed-culture/contamination prediction; Raman is second and may compete with growing spectral libraries and hardware advances; NIR remains cheap and reliable for measuring basic liquid constituents such as lipids, carbohydrates, and proteins.
  • NIR examples: Shao et al. predicted carotenoid content in *Spirulina* sp. suspensions with PLSR correlation coefficients as high as 0.96; Challagulla et al. predicted biomass and lipids in *Rhopalosolen saccatus* with Rcv values of 0.88, 0.93, and 0.93 for biomass and 0.72, 0.86, and 0.81 for total lipids for on-line liquid, off-line wet, and dry filter papers, respectively. In *Chlorella vulgaris*, on-line Vis-SW NIR biomass prediction had Rcv = 0.95 versus off-line wet 0.88 and dry 0.96, but total lipid content could not be predicted with much accuracy on-line.
  • Raman examples: Nadadoor et al. predicted glucose, biomass, and oil in a 2 L heterotrophic *Auxenochlorella prototheocoides* fed-batch with R² as high as 0.8867, 0.9822, and 0.8597 using support vector regression; Noack et al. reported SERDS/SVM extracellular polymeric substance prediction with PRESS = 0.031 versus PLSR PRESS = 0.48; Ren et al. achieved 93.3% accuracy for phenotypic match of *Nannochloropsis oceana* under nitrogen deplete/replete conditions using a database of 12,011 single-cell Raman spectra containing 14 strains.
  • MIR/automation examples: Girard et al. established R² > 99.9 for lactose, glucose, and galactose prediction by ATR-FTIR in mixotrophic *Scenedesmus obliquus*; Laurens and Wolfrum reported triglyceride predictions R² > 0.902 and phospholipid predictions R² = 0.588; Meng et al. used off-line FTIR carbohydrate/amide I ratio to predict photosynthetic efficiency with R² = 0.998; ATR-FTIR H2PO4− to HPO4−2 ratio was used for pH feedback control within ±0.15 pH units. MVPC, soft sensors, and nonlinear chemometrics such as ANNs, SVMs, and Kohonen networks are proposed for automation.

Methods

  • Design: critical review of current and prospective on-line/in-line process analytical technology using MIR, NIR, and Raman vibrational spectroscopies for microalgal process monitoring, including a comprehensive overview of off-line implementations.
  • Data or sample: literature-based synthesis; no primary experimental sample is reported. Figures categorize applications by species/strain, research focus, and major/minor products.
  • Main analysis: qualitative and critical assessment of hardware, chemometrics, and automation, citing reported prediction metrics from selected studies.

Limitations

  • The paper states that MIR suffers from water interference; ATR-FTIR fiber optics with sufficient MIR transmission are limited and costly, require very short cables, and may not be suitable for multiplexing. Raman is complicated by fluorescence and colored samples and is costly. NIR has lower detection than FTIR, and total lipid predictions were often only successful on dry filter papers. Soft sensor building is nontrivial and robustness is contingent on the frequency of analysis of the desired CQA. Most microalgal MIR research is off-line on dry or lyophilized samples, and Raman and ATR-FTIR had not been used to differentiate microalgal cells in suspensions.
  • Evident from the text: as a review, it presents no new primary data and relies on heterogeneous cited studies; several referenced figures and tables are not fully available in the provided text.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1080/07388551.2017.1398132

Cites

132 of 132 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

9 Valid · 10 Not valid · 41 Not checked · 39 Own results and interpretations

19 more claims

Create a free account to see all 99 claims and to verify the 1 reference still open.

See all claims — free account
  • It may state two separate claims as one. 37
  • Probably not a substantial claim. 47
  • Borderline: one of the tests for a substantial claim is unclear. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 130 references

Research works printed but not linked: 8

  1. Ge Y., 2016, Trans ASABE, 59:435–442
  2. Bernard O, 2015, Adv Biochem Eng Biotechnol, 153, 59
  3. Havlik I, 2016, Adv Biochem Eng Biotechnol, 153, 89
  4. ICH. Pharmaceutical Development Q8(R2): ICH Harmonised Tripartite Guideline. International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use [Internet]. 2009 [cited 2016 Dec 3]. p. 1–24. Available from: http://www.ich.org/fileadmin/Public_Web_Site/ICH_Products/Guidelines/Quality/Q8_R1/Step4/Q8_R2_Guideline.pdf.
  5. 10.1002/9783527654703 · DOI · Paper page
  6. Parab NDT, 2012, J Nanomed Nanotechnol, 3, 1000131
  7. Steyer J., 2002, Water Sci Technol, 45
  8. Samek O, 2012, Spectrosc Eur, 24, 22

Cited by

See all 34

Metadata

Authors
Podevin, M., Fotidis, I. A., & Angelidaki, I.
Affiliations
  • Technical University of Denmark (DK)
  • Department of Environmental Engineering, Technical University of Denmark, Lyngby, Denmark
Venue
Critical Reviews in Biotechnology
Published
2017-11-27
Volume
38
Issue
5
Pages
704-718
ISSN
  • 0738-8551 (ISSN-L)
  • 1549-7801
OpenAlex
W2768649232
Cited by
34
References
130
Citations by year
2026: 3 · 2025: 7 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 4 · 2018: 2
FWCI
0.32
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Critical Reviews in Biotechnology (publishedVersion)
  • PubMed (publishedVersion)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion, other-oa)
Funders
  • European Commission
  • Economically and Ecologically Efficient Water Management (280756)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Algal biology and biofuel production
Keywords
microalgae biorefinery, process analytical technology, real-time process monitoring, in-line monitoring, mid-infrared spectroscopy, near-infrared spectroscopy, Raman spectroscopy, multivariate statistical process control, soft sensors, big data, process automation, lipid content, product quality control
MeSH terms
Spectrum Analysis, Raman, Bioreactors, Spectroscopy, Near-Infrared, Microalgae

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives. https://app.cochat.ai/papers/10.1080/07388551.2017.1398132
The paper
Podevin, M., Fotidis, I. A., & Angelidaki, I. (2018). Microalgal process-monitoring based on high-selectivity spectroscopy tools: status and future perspectives. Critical Reviews in Biotechnology. https://doi.org/10.1080/07388551.2017.1398132

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.