Relation of transmitral flow velocity patterns to left ventricular diastolic function: New insights from a combined hemodynamic and Doppler echocardiographic study
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
In an effort to determine what clinically useful information regarding left ventricular diastolic function can be inferred noninvasively with pulsed wave Doppler echocardiography, mitral flow velocity patterns and measured variables were correlated with hemodynamic findings in 70 patients: 30 with coronary artery disease, 20 with idiopathic congestive cardiomyopathy, 14 with a restrictive myocardial process and 6 without significant cardiac disease. The effect of sudden changes in hemodynamics on the mitral flow velocity pattern was also investigated in a subgroup of patients who had simultaneous recording of mitral flow velocity and left ventricular pressure before and after left ventriculography. Mitral flow velocity recordings from 30 healthy adults served as a reference group. This analysis suggests that 1) the majority of patients with these cardiac disorders demonstrate abnormal mitral flow velocity patterns or variables; 2) markedly different flow velocity patterns can be seen in patients with impaired left ventricular relaxation; 3) the different mitral patterns appear to relate more to myocardial function and hemodynamic status than to the type of disease process present; 4) certain mitral patterns suggest different filling pressures and rates of early diastolic left ventricular filling; 5) an increase in left atrial pressure can "normalize" an abnormal mitral flow velocity pattern and "mask" a left ventricular relaxation abnormality; and 6) the different patterns appear to represent a dynamic continuum with the potential to change from one to another as a result of disease progression, medical therapy or sudden changes in hemodynamics. It is concluded that, despite the indirect method of estimation and certain limitations, mitral flow velocity recordings have clinical potential in assessing left ventricular diastolic function that merits further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sahn, D. J., DeMaria, A., Kisslo, J., & Weyman, A. (1978) · Circulation · doi:10.1161/01.cir.58.6.1072 · Cited by 7,430
Hemodynamic determinants of the time-course of fall in canine left ventricular pressure.
Weiss, J. L., Frederiksen, J. W., & Weisfeldt, M. L. (1976) · Journal of Clinical Investigation · doi:10.1172/jci108522 · Cited by 1,077
Preload dependence of doppler-derived indexes of left ventricular diastolic function in humans
Choong, C. Y., Herrmann, H. C., Weyman, A. E., & Fifer, M. A. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80273-5 · Cited by 624
Bonow, R. O., Bacharach, S. L., Green, M. V., Kent, K. M., Rosing, D. R., Lipson, L. C., Leon, M. B., & Epstein, S. E. (1981) · Circulation · doi:10.1161/01.cir.64.2.315 · Cited by 573
Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound.
Hatle, L., Brubakk, A., Tromsdal, A., & Angelsen, B. (1978) · Heart · doi:10.1136/hrt.40.2.131 · Cited by 539
Self-citationRokey, R., Kuo, L. C., Zoghbi, W. A., Limacher, M. C., & Quinones, M. A. (1985) · Circulation · doi:10.1161/01.cir.71.3.543 · Cited by 530
Triple control of relaxation: implications in cardiac disease.
Brutsaert, D. L., Rademakers, F. E., & Sys, S. U. (1984) · Circulation · doi:10.1161/01.cir.69.1.190 · Cited by 443
Raff, G. L., & Glantz, S. A. (1981) · Circulation Research · doi:10.1161/01.res.48.6.813 · Cited by 440
Spirito, P., Maron, B. J., & Bonow, R. O. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80461-2 · Cited by 421
Maron, B. J., Spirito, P., Green, K. J., Wesley, Y. E., Bonow, R. O., & Arce, J. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80264-4 · Cited by 410
Hanrath, P., Mathey, D. G., Siegert, R., & Bleifeld, W. (1980) · The American Journal of Cardiology · doi:10.1016/0002-9149(80)90214-3 · Cited by 400
Miyatake, K., Okamoto, M., Kinoshita, N., Owa, M., Nakasone, I., Sakakibara, H., & Nimura, Y. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90035-3 · Cited by 392
Doppler characterization of left ventricular diastolic function in cardiac amyloidosis
Klein, A. L., Hatle, L., Burstow, D. J., Seward, J. B., Kyle, R. A., Bailey, K. R., Lüscher, T. F., Gertz, M. A., & Tajik, A. J. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90254-4 · Cited by 335
Self-citationKITABATAKE, A., INOUE, M., ASAO, M., TANOUCHI, J., MASUYAMA, T., ABE, H., MORITA, H., SENDA, S., & MATSUO, H. (1982) · Japanese Circulation Journal · doi:10.1253/jcj.46.92 · Cited by 330
A clinical study of left ventricular relaxation.
Hirota, Y. (1980) · Circulation · doi:10.1161/01.cir.62.4.756 · Cited by 293
Aroesty, J. M., McKay, R. G., Heller, G. V., Royal, H. D., Als, A. V., & Grossman, W. (1985) · Circulation · doi:10.1161/01.cir.71.5.889 · Cited by 249
Kuo, L. C., Quinones, M. A., Rokey, R., Sartori, M., Abinader, E. G., & Zoghbi, W. A. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90870-8 · Cited by 239
Doppler evaluation of left ventricular diastolic filling in children with systemic hypertension
Snider, A. R., Gidding, S. S., Rocchini, A. P., Rosenthal, A., Dick, M., Crowley, D. C., & Peters, J. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90405-9 · Cited by 235
Left ventricular relaxation and filling in hypertrophic cardiomyopathy. An echocardiographic study.
Sanderson, J. E., Traill, T. A., Sutton, M. G., Brown, D. J., Gibson, D. G., & Goodwin, J. F. (1978) · Heart · doi:10.1136/hrt.40.6.596 · Cited by 180
Doppler echocardiography analysis of left ventricular filling in treated hypertensive patients
Phillips, R. A., Coplan, N. L., Krakoff, L. R., Yeager, K., Ross, R. S., Gorlin, R., & Goldman, M. E. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80382-0 · Cited by 164
Gamble, W. H., Shaver, J. A., Alvares, R. F., Salerni, R., & REDDY, P. S. (1983) · Circulation · doi:10.1161/01.cir.68.1.76 · Cited by 137
Standardized Intracardiac Measurements of Two-Dimensional Echocardiography
Schnittger, I., Gordon, E., Fitzgerald, P. J., & Popp, R. L. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80242-3 · Cited by 116
Self-citationMyocardial relaxation and passive diastolic properties in man.
Pasipoularides, A. D., MIRSKY, I., Hess, O. M., Grimm, J., & Krayenbuehl, H. P. (1986) · Circulation · doi:10.1161/01.cir.74.5.991 · Cited by 113
Diastolic function of the heart in untreated primary hypertension.
Hartford, M., Wikstrand, J., Wallentin, I., Ljungman, S., Wilhelmsen, L., & Berglund, G. (1984) · Hypertension · doi:10.1161/01.hyp.6.3.329 · Cited by 111
Sabbah, H. N., & Stein, P. D. (1981) · Circulation Research · doi:10.1161/01.res.48.3.357 · Cited by 98
Iwase, M., Sotobata, I., Takagi, S., Miyaguchi, K., Jing, H. X., & Yokota, M. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80313-3 · Cited by 79
Cited by
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Self-citationRecommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Self-citationRecommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Self-citationNagueh, S. F., Middleton, K. J., Kopelen, H. A., Zoghbi, W. A., & Quiñones, M. A. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00344-6 · Cited by 3,029
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew082 · Cited by 2,425
Self-citation
Metadata
- Authors
- Appleton, C. P., Hatle, L. K., & Popp, R. L.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1988-08
- Volume
- 12
- Issue
- 2
- Pages
- 426-440
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2014671408
- Cited by
- 1,568
- References
- 26
- FWCI
- 39.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.