Preliminary results of an absorbable interference screw
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
A randomized, prospective multicenter comparison was done of a bioabsorbable interference screw (Bioscrew; Linvatec Corp, Largo, FL) made from poly L‐lactic acid and a metal interference screw produced by the same company. Assignment was randomized by sealed envelopes. A total of 110 patients underwent arthroscopic patellar tendon autografts. A minimum 12 months follow‐up is available on 85 patients (mean 19 months, range 12 to 33) including 42 with Bioscrews and 43 with metal screws. There were 56 male and 29 female patients. The average age was 29 years (16 to 50 years). Tourniquet times and associated surgical findings were similar for the two groups. Postoperative Tegner and Lysholm scores were not statistically different between the two groups. KT tests at 1 year showed an average 20‐lb laxity of 1.8 mm for the Bioscrew and 1.2 mm for the metal screw groups. The average 1‐year KT maximum manual side‐to‐side difference was 1.6 mm for Bioscrews and 1.6 mm for metal screws. A pivot shift was absent in 83% of Bioscrews and 90% of metal screws at follow‐up. Six of 85 Bioscrews inserted (7%) broke on insertion (all were 7‐mm diameter screws at the femoral site). No additional fixation was required in four cases. In two, the broken screw was replaced. No lytic bone changes or tunnel widening were found with any Bioscrew. One metal screw had tibial tunnel widening. No statistical difference was found between the Bioscrew and the metal screw groups. Short‐term data support the conclusion that the Bioscrew is a reasonable alternative to metal interference screws.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Another important advantage is avoiding a second surgical procedure to remove unnecessary hardware, which reduces medical costs and allows for the gradual recovery of tissue function as the device is degraded simply by hydrolysis without any use of enzymes or catalysts (Fig. 13) [1,44,279].”
From Physical and mechanical properties of PLA, and their functions in widespread applications — A comprehensive review (2016) · cites this paper as [279]
Citations
Cites
Rating systems in the evaluation of knee ligament injuries
TEGNER, Y., & LYSHOLM, J. (1985) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198509000-00007 · Cited by 4,613
Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale
Lysholm, J., & Gillquist, J. (1982) · The American Journal of Sports Medicine · doi:10.1177/036354658201000306 · Cited by 2,775
Kurosaka, M., Yoshiya, S., & Andrish, J. T. (1987) · The American Journal of Sports Medicine · doi:10.1177/036354658701500306 · Cited by 745
Clancy, W. G., Nelson, D. A., Reider, B., & Narechania, R. G. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264030-00004 · Cited by 581
OʼBrien, S. J., Warren, R. F., Pavlov, H., Panariello, R., & Wickiewicz, T. L. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173020-00016 · Cited by 501
Biodegradable bone repair materials. Synthetic polymers and ceramics.
Hollinger, J. O., & Battistone, G. C. (1986) · PubMed · Cited by 486
Absorbable implants for the fixation of fractures.
Böstman, O. M. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173010-00022 · Cited by 459
Biodegradable Bone Repair Materials: Synthetic Polymers and Ceramics
HOLLINGER, J. O., & BATTISTONE, G. C. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198606000-00046 · Cited by 381
Osteolytic changes accompanying degradation of absorbable fracture fixation implants
Bostman, O. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.1649195 · Cited by 294
Knee rehabilitation after anterior cruciate ligament reconstruction and repair
Paulos, L., Noyes, F. R., Grood, E., & Butler, D. L. (1981) · The American Journal of Sports Medicine · doi:10.1177/036354658100900303 · Cited by 270
Self-citation
Research works printed but not linked: 6
- Brostrom L, 1968, Behandling av invetererad ruptur av framre korsbandet, Lakartidningen, 64, 4477
- Alm A, 1974, Reconstruction of the anterior cruciate ligament by using the medial third of the patellar ligament, Acta Chir Scand, 140, 289
- James P, 1989, Stable fixation of bone‐tendon‐bone grafts in ACL reconstruction, Am J Knee Surg, 2, 71
- Bach BR, 1989, Potential pitfalls of Kurosaka screw interference fixation for ACL surgery, Am J Knee Surg, 2, 76
- FChabot PChristel MVert.In vivo tests of bioresorbable bone plates in long lasting poly (L‐lactic acid)UPAC Symposium Prague Czechoslovakia Ed 1 Polymers in Medicine and Biology July 9–12 1987
- BFElrod.Arthroscopic shoulder stabilization with a bioabsorbable takPresented at the Arthroscopy Association of North America Annual Meeting. April 1–4 1993 · doi:10.1097/00132585-199300140-00005
Cited by
Items 101–180 of 180
The Principles of Interference Screw Fixation: Application to Foot and Ankle Surgery
Feldman, K. A. (2005) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2005.07.024 · Cited by 18
Wysocki, R. W., Cohen, M. S., Shott, S., & Fernandez, J. J. (2010) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2010.03.013 · Cited by 17
Ammon, J. T., Voor, M. J., & Tillett, E. D. (2005) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2005.09.005 · Cited by 16
Kajiyama, T., Kobayashi, H., Morisaku, K., Taguchi, T., Kataoka, K., & Tanaka, J. (2004) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2003.10.005 · Cited by 16
Barnhart, M. D., Watson, A. T., Thatcher, L. G., Wotton, H., & Naber, S. J. (2016) · Veterinary Surgery · doi:10.1111/vsu.12502 · Cited by 15
“Good clinical results with minimal evidence of inflammation and consistent gradual, complete degradation was reported using the first-generation interference screws made of poly L-lactide homopolymer.(8,9) Additionally, these bioabsorbable screws stabilized grafts with”
BackgroundBiodegradable Polymers for Orthopaedic Applications
Agrawal, C. M. (2002) · Springer eBooks · doi:10.1007/978-94-010-0305-6_3 · Cited by 15
Marks, P., O’Donnell, S. C., & Yee, G. (2008) · The Knee · doi:10.1016/j.knee.2007.11.004 · Cited by 14
“The interference screw is the most widely used [6–9] fixation technique for BPTB graft fixation and has been shown to withstand greater loads to failure compared to devices such as”
MethodBiodegradable Composite Implants
Schlichting, K., Dahne, M., & Weiler, A. (2006) · Sports Medicine and Arthroscopy Review · doi:10.1097/00132585-200609000-00009 · Cited by 16
Powers, D. L., Sonawala, M., Woolf, S. K., An, Y. H., Hawkins, R. J., & Pietrzak, W. S. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1045 · Cited by 13
Graft Fixation Alternatives in Anterior Cruciate Ligament Reconstruction
Robbe, R., & Johnson, D. L. (2002) · Cited by 13
Study on the hydrolytic degradation of poly(α,β-malic acid) by direct polycondensation
Kajiyama, T., Kobayashi, H., Taguchi, T., Komatsu, Y., Kataoka, K., & Tanaka, J. (2004) · Materials Science and Engineering C · doi:10.1016/j.msec.2004.08.029 · Cited by 12
Gawęda, K., Walawski, J., Węgłowski, R., & Krzyżanowski, W. (2007) · International Orthopaedics · doi:10.1007/s00264-007-0482-y · Cited by 12
“Even from the very beginning Barber reported some complications as follows: 7% broken screws and 1 in 42 cases of “unexpected anterior and medial knee pain” that required arthroscopy [4].”
InfluentialHofmann, G. O., Wagner, F. D., Beickert, R., Gonschorek, O., & Bühren, V. (2001) · European Journal of Trauma · doi:10.1007/s00068-001-1089-4 · Cited by 12
“In literature only few studies on this topic have been published up to now [3, 34, 45].”
BackgroundPiltz, S., Strunk, P., Meyer, L., Plitz, W., & Lob, G. (2004) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-003-0463-7 · Cited by 12
Torsion test method for mechanical characterization of PLDLA 70/30 ACL interference screws
Roesler, C. R. D. M., Salmoria, G. V., Moré, A. D. O., Vassoler, J. M., & Fancello, E. A. (2013) · Polymer Testing · doi:10.1016/j.polymertesting.2013.12.005 · Cited by 11
Hackl, W., Benedetto, K. P., Hoser, C., Künzel, K. H., & Fink, C. (2000) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/jars.2000.4825 · Cited by 11
Bioresorbable fixation devices for musculoskeletal injuries in adults
Jainandunsing, J., van der Elst, M., & van der Werken, C. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004324.pub2 · Cited by 11
RetractedDenti, M., Randelli, P. S., Vetere, D. L., Moioli, M., & Tagliabue, M. (2004) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-004-0062-5 · Cited by 10
“In vitro studies [12, 13] have shown that their fixation property is the same as that of metal screws and their employment does not result in any clinical differences [11, 14, 15].”
BackgroundBarth, J. R. H., Akritopoulos, P., Graveleau, N., Barthélémy, R., Toanen, C., & Saffarini, M. (2016) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967116647724 · Cited by 10
“Male sex, n (%) 8 (53) 7 (58) NS IKDC score (preoperative), n (%) NS B 1 (7) 1 (8) C 12 (80) 11 (92) D 2 (13) 0 (0)”
InfluentialGraft fixation issues in kneeligament surgery
Brand, J. C., Weiler, A., Caborn, D. N. M., & Johnson, D. L. (1999) · Operative Techniques in Orthopaedics · doi:10.1016/s1048-6666(99)80003-2 · Cited by 10
An Experimental Study of Heat Adaptation of Bioabsorbable Craniofacial Meshes and Plates
Pietrzak, W. S., & Eppley, B. L. (2007) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e318052fdeb · Cited by 9
Umar, M., Baqai, N., & Peck, C. (2009) · BMJ Case Reports · doi:10.1136/bcr.09.2008.1007 · Cited by 9
Hegde, A. S., Deepak, K., & Kannampilly, A. J. (2014) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2014/8834.4237 · Cited by 9
“Over several years, fixations for ACL reconstructions have been performed by using metal interference screws [3].”
BackgroundHalder, A. M., Ludwig, S., & Neumann, W. (2002) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/jars.2002.36107 · Cited by 9
Seitz, H., Vécsei, V., Menth‐Chiari, W. A., Pichl, W., Wielke, B., & Marlovits, S. (1999) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/ar.1999.v15.015017 · Cited by 9
RETRACTED ARTICLE: Graft fixation alternatives in anterior cruciate ligament reconstruction
Saccomanni, B. (2011) · MUSCULOSKELETAL SURGERY · doi:10.1007/s12306-011-0137-4 · Cited by 8
“Although lower fixation strengths have been reported with bioabsorbable interference screws [33], most studies indicate comparable strength and stiffness in sideby-side comparisons of metal and bioabsorbable interference screws [11, 29, 33–42].”
BackgroundResultRetractedWang, Z., Wang, S., Guidoin, R., Marois, Y., & Zhang, Z. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30739 · Cited by 8
Scrivens, B., Kluczynski, M. A., Fineberg, M. S., & Bisson, L. J. (2021) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671211006477 · Cited by 7
Piltz, S., Dieckmann, R., Meyer, L., Strunk, P., Plitz, W., & Lob, G. (2005) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-005-0007-3 · Cited by 6
“Another reported complication associated with the use of biodegradable interference screws is the breakage during insertion [2, 19, 21].”
BackgroundBiodegradable Hard Tissue Implants
METU, B., Aydin, E., Vasif, H., & METU, B. (2010) · Journal of Siberian Federal University Biology · doi:10.17516/1997-1389-0213 · Cited by 6
“According to a randomized clinical trial on 85 patients having arthroscopic patellar tendon autografts (Barber et al., 1995), commercial PLLA interference screws showed essentially no difference in terms of ease of application or patient’s healing period when compared to metal screws used in the same application.”
Tendon and Ligament Fixation to Bone
Hill, C. M., An, Y. H., & Young, F. A. (2006) · Humana Press eBooks · doi:10.1385/1-59259-942-7:257 · Cited by 5
Retraction Note: Graft fixation alternatives in anterior cruciate ligament reconstruction
Saccomanni, B. (2012) · MUSCULOSKELETAL SURGERY · doi:10.1007/s12306-012-0212-5 · Cited by 5
A Structural Optimization Framework for Biodegradable Magnesium Interference Screws
Shen, Z., Zhou, X., Zhao, M., & Li, Y. (2025) · Biomimetics · doi:10.3390/biomimetics10040210 · Cited by 4
“Since the performance of interference screws depends on both corrosion behavior and mechanical integrity [23,24], optimization strategies must incorporate corrosion models to simulate screw degradation.”
Biodegradable Metals and Responsive Biosensors for Musculoskeletal Applications
Liu, H. H. (2010) · Springer eBooks · doi:10.1007/978-1-4419-7291-0_6 · Cited by 4
Surgical techniques to correct nonanatomic femoral tunnels
Dalton, J. D., & Harner, C. D. (1998) · Operative Techniques in Sports Medicine · doi:10.1016/s1060-1872(98)80054-3 · Cited by 4
Vaquero, J., Vidal, C., & Cubillo, A. (1997) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(97)90018-9 · Cited by 4
Bioabsorbable Expansion Bolt Fixation in Anterior Cruciate Ligament Reconstruction
Piltz, S., Steinbauer, T., Meyer, L., Plitz, W., Andreß, H.-J., & Lob, G. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200401000-00039 · Cited by 4
“Despite the advantages of bioabsorbable screws, breakage of the screw was seen during insertion.(1,16,17,28,31) Moreover, in the current series screw breakage was seen once when a torque greater than 3.”
BackgroundMethodGraft fixation in ACL reconstruction
Kousa, P. (2004) · Tampere University Institutional Repository (Tampere University) · Cited by 4
Parsons, E. M., Yu, J. S., Pedroza, A. D., & Kaeding, C. C. (2013) · The Knee · doi:10.1016/j.knee.2013.03.001 · Cited by 3
“suggesting that these devices perform as well as their metal counterparts [17–24].”
BackgroundArthroskopische Rekonstruktion des vorderen Kreuzbandes in Press-fit-Technik
Halder, A. M. (2010) · Der Unfallchirurg · doi:10.1007/s00113-010-1828-2 · Cited by 3
Milam, R. J., Drayer, N. J., Wallace, C. S., Kang, D. G., & Masini, B. D. (2022) · Orthopedic Reviews · doi:10.52965/001c.37078 · Cited by 3
Tecklenburg, K., Hoser, C., Sailer, R., Oberladstätter, J., & Fink, C. (2005) · Der Unfallchirurg · doi:10.1007/s00113-005-0948-6 · Cited by 3
Bioabsorbable Polymers Used in Knee Arthroscopy, Part 1: Basic Science and Application
Siparsky, P. N., Gramenz, P., Gall, K. A., D'Ambrosia, R. D., & Bartz, R. L. (2006) · Techniques in Knee Surgery · doi:10.1097/01.btk.0000221928.66783.28 · Cited by 3
Anterior Cruciate Ligament Injuries and Reconstruction
Long, W. J., & Scott, W. N. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-1503-3.00041-x · Cited by 3
Abidin, N. A. Z., Wahab, A. A., Ramlee, M. H., & Kadir, M. R. A. (2018) · International Conference on BioSignal Analysis, Processing and Systems (ICBAPS) · doi:10.1109/icbaps.2018.8527418 · Cited by 3
Südkamp, N. P., Stähelin, A. C., Wagner, M. A., & Weiler, A. (2000) · Arthroskopie · doi:10.1007/s001420050175 · Cited by 3
“Daher haben biodegradierbare Interferenzschrauben zunehmend an Bedeutung für die Verankerung von Patellarsehnentransplantaten gewonnen, nachdem biomechanische und klinische Studien ihre Gleichwertigkeit im Vergleich zu Metallschrauben gezeigt haben [2, 5, 18, 25, 35].”
BackgroundRisinger, R. J., Verma, N. N., & Bach, B. R. (2005) · Techniques in Orthopaedics · doi:10.1097/01.bto.0000190447.30210.5c · Cited by 2
Bioresorbable fixation devices for musculoskeletal injuries in adults
Jainandunsing, J. S., van der Elst, M., & van der Werken, C. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004324.pub3 · Cited by 2
Biomechanics of Intratunnel Anterior Cruciate Ligament Graft Fixation
Chen, N. C., & Brown, C. H. (2008) · Elsevier eBooks · doi:10.1016/b978-1-4160-3834-4.10028-9 · Cited by 3
The Current Status and Prospects of Poly(Lactic Acid) Applications in Clinical Treatment
Yang, Z., Qiao, C., Liu, J., Qin, T., Gao, P., Chen, J., & Yin, G. (2024) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2024.3826 · Cited by 1
Finite Element Analyses of ACL Interference Screws: A Review
Hawkins, K. M., Flowers, J. R., & McCullough, M. B. A. (2013) · Cited by 1
Arthroscopic Management of Shoulder Instability: Bio-Anchor (Linvatec)
Barber, F. A. (2001) · Springer eBooks · doi:10.1007/978-0-387-21541-9_9 · Cited by 1
Self-citationMilano, G., Petersen, W. J., Hoeher, J., Paessler, H. H., Akoto, R., Campana, V., Saccomanno, M. F., & Siebold, R. (2014) · Springer eBooks · doi:10.1007/978-3-642-45349-6_24 · Cited by 1
Kumar, N. N., Halbhavi, M. R., Gouthamraj, H., Kumar, T. N. S., Shivanna, H. Y., & Sahana, V. K. (2024) · Journal of Orthopaedic Case Reports · doi:10.13107/jocr.2024.v14.i05.4472 · Cited by 1
“Barber et al. compared 7 mm PLLA bio screws to metal interference screws and had femoral breakage in six patients out of 42 with no adverse functional outcomes [19].”
BackgroundIntratunnel Anterior Cruciate Ligament Graft Fixation
Mlynarek, R. A., Bedi, A., & Brown, C. H. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-38962-4.00061-8 · Cited by 1
Bioabsorbable Versus Metal Interference Screws
Laupattarakasem, W., & Laupattarakasem, P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-38962-4.00075-8 · Cited by 1
Bioresorbierbare Schrauben bei der arthroskopischen vorderen Kreuzbandplastik
Schwamborn, T., & Imhoff, A. B. (1998) · Steinkopff eBooks · doi:10.1007/978-3-642-50249-1_17 · Cited by 1
Tecklenburg, K., Hoser, C., Sailer, R., Oberladstätter, J., & Fink, C. (2005) · Der Unfallchirurg · Cited by 1
Protection of the bone-tendon-bone graft during anterior cruciate ligament reconstruction
Milankov, M. Z., Stankovic, M. D., & Miljkovic, N. D. (2005) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-004-0789-8 · Cited by 1
“The use of biodegradable interference screws also reduces the risk of graft laceration during screw insertion [2, 7].”
BackgroundLetter to the Editor: Fibroxanthoma: A Complication of a Biodegradable Screw
Bauer, T. W. (2010) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-010-1601-4 · Cited by 1
“Some cases of tunnel widening and bone resorption also have been associated with degrading polymer screws [3], although this is nonspecific as it also has been reported associated with metal screws [ 1 ].”
Bioabsorbable implants in knee surgery : An experimental and clinical study
Tuompo, P. (2004) · Helda - University of Helsinki Institutional Repository · Cited by 1
Polylactic Acid: Properties and Applications
Hamad, K., Kaseem, M., & Dezi, F. (2016) · Taylor & Francis eBooks · doi:10.1081/e-ebpp-120050007 · Cited by 1
Kim, K. E. (2014) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 1
Raviraj, A., Anand, A., & Santosh, K. (2012) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-012-0954-7
Bioabsorbable Polymers Used in Knee Arthroscopy, Part 2: Clinical Results
Gramenz, P., Siparsky, P. N., Gall, K. A., D'Ambrosia, R. D., & Bartz, R. L. (2006) · Techniques in Knee Surgery · doi:10.1097/01.btk.0000221929.66783.61
Barber, F. A. (2008) · Elsevier eBooks · doi:10.1016/b978-1-4160-3834-4.10051-4
Self-citationErste Ergebnisse der implantatfreien arthroskopischen Kreuzbandplastik in Double-Press-Fit-Technik
Halder, A. M., & Kreusch-Brinker, R. (1997) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-60913-8_165
Derzeitiger Stand biodegradabler Implantate
Rehm, K. E. (1997) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-60913-8_276
Möglichkeiten und Grenzen des Einsatzes biodegradierbarer Osteosyntheseimplantate-State of the Art
Hofmann, G. O. (1998) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-80390-1_2 · Cited by 2
Stähelin, C. (1998) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-80390-1_27
Zvezdkina, E. A., Lesnyak, V. N., Akhpashev, A. А., Александровна, Д. Е., & Семенович, К. А. (2016) · Journal of clinical practice · doi:10.17816/clinpract743-8
Ronco, J., González, X., Sagasti, I., Bralic, D., Iglesias, A., Aguayo, G., & Lavín, G. (2019) · Revista Chilena de Ortopedia y Traumatología · doi:10.1055/s-0039-1683989
(2006) · Springer eBooks · doi:10.1007/0-387-21594-8_11
Sawallich, T. (2011) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-920
Barber, F. A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-38962-4.00072-2
Self-citationLow, Y. J. (2024) · University of Malaya Students Repository
Graft Fixation in ACL Injuries: A Review
Bernardino, S. (2025) · International Journal of Family Medicine & Healthcare · doi:10.33425/2833-0382.1044
“Three potential disadvantages are screw breakage during insertion [16,38,39], an inflammatory response described with bioabsorbable implants [46] and inadequate fixation after partial degradation prior to biologic incorporation.”
Bozhokin, M. S., Korneva, Y. S., Labutin, D. V., Antipov, A. P., Nashchekina, Y. A., Velizhanina, M. E., Leonova, E., Sopova, J. V., Георгиевич, Х. М., & Божкова, С. А. (2026) · Regenerative Engineering and Translational Medicine · doi:10.1007/s40883-026-00580-8
Minister McEntee launches public consultation process on Spent Convictions Policy.
(2020) · HRB National Drugs Library (Health Research Board)
Metadata
- Authors
- Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E.
- Affiliations
- Plano Orthopedic Sports Medicine & Spine Center (US)
- Southern Sports Medicine And Orthopaedic Center Nashville Tennessee U.S.A.
- Knee and Arthroscopic Surgery Anchorage Alaska U.S.A.
- Orthopedic Specialty Hospital (US)
- Corresponding author
- Barber, F.Alan
- Venue
- Arthroscopy
- Publisher
- Wiley
- Published
- 1995-10
- Volume
- 11
- Issue
- 5
- Pages
- 537-548
- ISSN
- 0749-8063 (ISSN-L)
- 1526-3231
- OpenAlex
- W1968503265
- Cited by
- 178
- References
- 22
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 5 · 2018: 2 · 2017: 3 · 2016: 8 · 2015: 4 · 2014: 4 · 2013: 11 · 2012: 5
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Arthroscopy The Journal of Arthroscopic and Related Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
- Keywords
- bioabsorbable interference screw, poly(L-lactic acid), patellar tendon autograft, knee arthroscopy, screw fixation, pivot shift, knee laxity, KT-1000 arthrometry, screw breakage, tunnel widening
- MeSH terms
- Absorption, Adolescent, Adult, Arthroplasty, Bone Screws, Female, Follow-Up Studies, Humans, Knee Joint, Lactates, Male, Metals, Middle Aged, Polyesters, Polymers, Prospective Studies, Radiography, Tendons, Transplantation, Autologous, Anterior Cruciate Ligament, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.