Abstract
We have developed several training methods in conjunction with a convolution neural network for general medical image pattern recognition. An unconventional method of using rotation and shift invariance is also proposed to enhance the neural net performance. The structure of the artificial neural network is a simplified network structure of the neocognitron. Two-dimensional local connection as a group is the fundamental architecture for the signal propagation in the convolution neural network. Weighting coefficients of convolution kernels are formed by the neural network through backpropagated training for this artificial neural net. In addition, radiologists' reading procedure was modelled in order to instruct the artificial neural network to recognize the predefined image patterns and those of interest to experts. Our training techniques involve (a) radiologists' rating for each suspected image area, (b) backpropagation of generalized distribution, (c) trainer imposed functions, (d) shift and rotation invariance of diagnosis interpretation, and (e) consistency of clinical input data using appropriate background reduction functions. We have tested these methods for detecting lung nodules on chest radiographs and microcalcications on mammograms. The performance studies have shown the potential use of this technique in a clinical environment. We also used a profile double-matching technique for initial nodule search and used a wavelet high pass filtering technique to enhance subtle clustered microcalcifications. We set searching parameters at a highly sensitive level to identify all potential disease areas. The artificial convolution neural network acts as a final detection classifier to determine whether a disease pattern is shown on the suspected image area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Learning Internal Representations by Error Propagation
Rumelhart, D. E., Hinton, G. E., & Williams, R. J. (1985) · doi:10.21236/ada164453 · Cited by 16,172
Fukushima, K. (1980) · Biological Cybernetics · doi:10.1007/bf00344251 · Cited by 5,759
Neocognitron: A neural network model for a mechanism of visual pattern recognition
Fukushima, K., Miyake, S., & Ito, T. (1983) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1983.6313076 · Cited by 713
CHAN, H.-P., DOI, K., VYBRONY, C. J., SCHMIDT, R. A., METZ, C. E., LAM, K. L., OGURA, T., WU, Y., & MACMAHON, H. (1990) · Investigative Radiology · doi:10.1097/00004424-199010000-00006 · Cited by 359
Self-citationArtificial convolution neural network techniques and applications for lung nodule detection
Lo, S.-C. B., Lou, S.-L. A., Lin, J.-S., Freedman, M. T., Chien, M. V., & Mun, S. K. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.476112 · Cited by 348
Self-citationChan, H.-P., Doi, K., Galhotra, S., Vyborny, C. J., MacMahon, H., & Jokich, P. M. (1987) · Medical Physics · doi:10.1118/1.596065 · Cited by 342
Self-citationEffects of sample size in classifier design
Fukunaga, K., & Hayes, R. R. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.31448 · Cited by 320
Giger, M. L., Doi, K., & MacMahon, H. (1988) · Medical Physics · doi:10.1118/1.596247 · Cited by 250
Handwritten alphanumeric character recognition by the neocognitron
Fukushima, K., & Wake, N. (1991) · IEEE Transactions on Neural Networks · doi:10.1109/72.97912 · Cited by 217
Chan, H., Lo, S. B., Sahiner, B., Lam, K. L., & Helvie, M. A. (1995) · Medical Physics · doi:10.1118/1.597428 · Cited by 208
Self-citationEvaluation of Diagnostic Systems
(1982) · Elsevier eBooks · doi:10.1016/b978-0-12-679080-1.x5001-4 · Cited by 165
Wu, Y. C., Doi, K., Giger, M. L., & Nishikawa, R. M. (1992) · Medical Physics · doi:10.1118/1.596845 · Cited by 154
Non-small-cell lung cancer: results of the New York screening program.
Heelan, R. T., Flehinger, B. J., Melamed, M. R., Zaman, M. B., Perchick, W. B., Caravelli, J. F., & Martini, N. (1984) · Radiology · doi:10.1148/radiology.151.2.6324279 · Cited by 153
Analysis of the process of visual pattern recognition by the neocognitron
Fukushima, K. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90041-5 · Cited by 144
Shih-Chung, B. L., Freedman, M. T., Lin, J.-S., & Mun, S. K. (1993) · Journal of Digital Imaging · doi:10.1007/bf03168418 · Cited by 94
Self-citationGiger, M. L., Ahn, N., Doi, K., MacMahon, H., & Metz, C. E. (1990) · Medical Physics · doi:10.1118/1.596478 · Cited by 94
Planning a totally digital radiology department.
Huang, H. K., Kangarloo, H., Cho, P. S., Taira, R. K., Ho, B. K. T., & Chan, K. K. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.154.3.2106235 · Cited by 36
Gómez-Morán, M. C. (1995) · PubMed · Cited by 29
PACS clinical experience at Georgetown University
Horii, S. C., Mun, S. K., Levine, B. A., Lo, B., Garra, B. S., Zeman, R. K., Freedman, M. T., Leftridge, C. A., Schellinger, D., Keyes, J. W., et al. (1991) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(91)90008-j · Cited by 15
Self-citationFEASIBILITY OF COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY
Doi, K., Katsuragawa, S., M.LGIGER, Fujita, H., & MacMahon, H. (1989) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.kj00001358902 · Cited by 11
Cited by
Setio, A. A. A., Ciompi, F., Litjens, G., Gerke, P., Jacobs, C., van Riel, S. J., Wille, M. M. W., Naqibullah, M., Sanchez, C. I., & van Ginneken, B. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2536809 · Cited by 1,258
“[19] is the only study which used ConvNets specifically trained for”
MethodOverview of deep learning in medical imaging
Suzuki, K. (2017) · Radiological Physics and Technology · doi:10.1007/s12194-017-0406-5 · Cited by 1,087
Deep Learning in Medical Image Analysis
Chan, H.-P., Samala, R. K., Hadjiiski, L. M., & Zhou, C. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-030-33128-3_1 · Cited by 747
Self-citationHuynh, B. Q., Li, H., & Giger, M. L. (2016) · Journal of Medical Imaging · doi:10.1117/1.jmi.3.3.034501 · Cited by 539
Self-citationDeep learning for automated skeletal bone age assessment in X-ray images
Spampinato, C., Palazzo, S., Giordano, D., Aldinucci, M., & Leonardi, R. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.10.010 · Cited by 434
Metadata
- Authors
- Lo, S.-C. B., Chan, H.-P., Lin, J.-S., Li, H., Freedman, M. T., & Mun, S. K.
- Venue
- Neural Networks
- Publisher
- Elsevier BV
- Published
- 1995
- Volume
- 8
- Issue
- 7-8
- Pages
- 1201-1214
- ISSN
- 0893-6080 (ISSN-L)
- OpenAlex
- W2063217105
- Cited by
- 321
- References
- 20
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.