Detection of vapours and odours from a multisensor array using pattern recognition Part 1. Principal component and cluster analysis
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Properties of Germanium
Brattain, W. H., & Bardeen, J. (1953) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1953.tb01420.x · Cited by 601
Selection of adsorbates for chemical sensor arrays by pattern recognition
Carey, W. P., Beebe, K. R., Kowalski, B. R., Illman, D. L., & Hirschfeld, T. (1986) · Analytical Chemistry · doi:10.1021/ac00292a036 · Cited by 200
Application of artificial neural networks to an electronic olfactory system
Gardner, J. W., Hines, E. L., & Wilkinson, M. (1990) · Measurement Science and Technology · doi:10.1088/0957-0233/1/5/012 · Cited by 158
Self-citationIntelligent vapour discrimination using a composite 12-element sensor array
Shurmer, H. V., Gardner, J. W., & Corcoran, P. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80211-h · Cited by 120
Self-citation
Cited by
Cross-Reactive Chemical Sensor Arrays
Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000) · Chemical Reviews · doi:10.1021/cr980102w · Cited by 1,284
A brief history of electronic noses
Gardner, J. W., & Bartlett, P. N. (1994) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(94)87085-3 · Cited by 1,255
Self-citationApplications and Advances in Electronic-Nose Technologies
Wilson, A. D., & Baietto, M. (2009) · Sensors · doi:10.3390/s90705099 · Cited by 1,144
Array-Based Vapor Sensing Using Chemically Sensitive, Carbon Black−Polymer Resistors
Lonergan, M. C., Severin, E. J., Doleman, B. J., Beaber, S. A., Grubbs, R. H., & Lewis, N. S. (1996) · Chemistry of Materials · doi:10.1021/cm960036j · Cited by 633
Pattern analysis for machine olfaction: a review
Gutierrez-Osuna, R. (2002) · IEEE Sensors Journal · doi:10.1109/jsen.2002.800688 · Cited by 578
Hierlemann, A., & Gutierrez-Osuna, R. (2008) · Chemical Reviews · doi:10.1021/cr068116m · Cited by 456
Sensor arrays for liquid sensing – electronic tongue systems
Ciosek, P., & Wróblewski, W. (2007) · The Analyst · doi:10.1039/b705107g · Cited by 408
Electronic Nose Feature Extraction Methods: A Review
Yan, J., Guo, X., Duan, S., Jia, P., Wang, L., Peng, C., & Zhang, S. (2015) · Sensors · doi:10.3390/s151127804 · Cited by 338
Srivastava, A. K. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00477-5 · Cited by 237
Application of an electronic nose to the discrimination of coffees
Gardner, J. W., Shurmer, H. V., & Tan, T. T. (1992) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(92)80033-t · Cited by 200
Self-citationTea quality prediction using a tin oxide-based electronic nose: an artificial intelligence approach
Dutta, R., Hines, E. L., Gardner, J. W., Kashwan, K. R., & Bhuyan, M. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00367-8 · Cited by 198
Self-citationGoodey, A., Lavigne, J. J., Savoy, S. M., Rodriguez, M. D., Curey, T., Tsao, A., Simmons, G., Wright, J., Yoo, S.-J., Sohn, Y., et al. (2001) · Journal of the American Chemical Society · doi:10.1021/ja003341l · Cited by 189
Llobet, E., Brezmes, J., Vilanova, X., Sueiras, J. E., & Correig, X. (1997) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(97)80272-9 · Cited by 188
Jin, H., Huynh, T.-P., & Haick, H. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01066 · Cited by 167
Metadata
- Authors
- Gardner, J. W.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 1991-05
- Volume
- 4
- Issue
- 1-2
- Pages
- 109-115
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W1985288104
- Cited by
- 314
- References
- 4
- FWCI
- 12.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.