Automated assignment of charge states from resolved isotopic peaks for multiply charged ions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The recent proliferation of electrospray as an ionization method has greatly increased the ability to perform analyses of large biomolecules by using mass spectrometry. The major advantage of electrospray is the ability to produce multiply charged ions, which brings large molecules down to a mass-to-charge ratio range amenable to most instruments. Multiple charging is also a disadvantage because mass (m) becomes ambiguous unless charge (z) can be assigned. This is typically performed with simple algorithms that use multiple peaks of the same m and different z, but these methods are difficult to apply to complex mixtures and not applicable when only one z appears for each m. The use of mass analyzers with higher resolving powers, like the Fourier transform mass spectrometer, allows resolution of isotopic peaks, providing an internal 1-Da mass scale that can be used for unambiguous charge assignment. Manual assignment of charge state from the isotopic peaks is time consuming and becomes inaccurate when either the signal level or resolving power are low. For these cases, computer algorithms based on pattern recognition techniques have been developed to assist in assignment of charge states to isotopic clusters. These routines provide for more rapid analysis with higher accuracy than available manually.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Petroleomics: Chemistry of the underworld
Marshall, A. G., & Rodgers, R. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805069105 · Cited by 673
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Self-citationZhang, Z., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00284-5 · Cited by 509
Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
Self-citationComplete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371
Metadata
- Authors
- Senko, M. W., Beu, S. C., & McLafferty, F. W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-01-01
- Volume
- 6
- Issue
- 1
- Pages
- 52-56
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2073162961
- Cited by
- 119
- References
- 2
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated assignment of charge states from resolved isotopic peaks for multiply charged ions. https://app.cochat.ai/papers/10.1016/1044-0305(94)00091-d
- The paper
- Senko, M. W., Beu, S. C., & McLafferty, F. W. (1995). Automated assignment of charge states from resolved isotopic peaks for multiply charged ions. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/1044-0305(94)00091-d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.