The DOI matches its Crossref record.
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Abstract
A "micro-electrospray" ionization source has been developed that markedly increases the sensitivity of the conventional electrospray source. This was achieved by optimization of the source to accommodate nanoliter flow rates from 300 to 800-nL/min spraying directly from a capillary needle that, for the analysis of peptides, contained C18 liquid chromatography packing as an integrated concentration-desalting device. Thus, a total of 1 fmol of methionine enkephalin was desorbed from the capillary column spray needle, loaded as a 10-μL injection of 100-amol/μL solution. The mass spectrum showed the [M + H](+) ion at m/z 574.2 with a signal-to-noise ratio of better than 5:1 from a chromatographic peak with a width of about 12 s. A narrow range (15-u) tandem mass spectrum was obtained for methionine enkephalin from the injection of 500 amol, and a full-scan tandem-mass spectrum was obtained from 50 fmol. For proteins, the average mass measurement accuracy was approximately 100-200 ppm for the injection of 2.5 fmol of apomyoglobin and 20-40 ppm for 200 fmol. Carbonic anhydrase B and bovine serum albumin showed similar mass measurement accuracies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Ultra‐high sensitivity mass spectrometry quantifies single‐cell proteome changes upon perturbation
Brunner, A., Thielert, M., Vasilopoulou, C., Ammar, C., Coscia, F., Mund, A., Hoerning, O. B., Bache, N., Apalategui, A., Lubeck, M., et al. (2022) · Molecular Systems Biology · doi:10.15252/msb.202110798 · Cited by 544
Senko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Self-citationAttomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
Microcolumns with self-assembled particle frits for proteomics
Ishihama, Y., Rappsilber, J., Andersen, J. S., & Mann, M. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01402-4 · Cited by 323
Metadata
- Authors
- Emmett, M. R., & Caprioli, R. M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-07-01
- Volume
- 5
- Issue
- 7
- Pages
- 605-613
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2066486253
- Cited by
- 510
- References
- 0
- FWCI
- 15.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins. https://app.cochat.ai/papers/10.1016/1044-0305(94)85001-1
- The paper
- Emmett, M. R., & Caprioli, R. M. (1994). Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/1044-0305(94)85001-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.