Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A "micro-electrospray" ionization source has been developed that markedly increases the sensitivity of the conventional electrospray source. This was achieved by optimization of the source to accommodate nanoliter flow rates from 300 to 800-nL/min spraying directly from a capillary needle that, for the analysis of peptides, contained C18 liquid chromatography packing as an integrated concentration-desalting device. Thus, a total of 1 fmol of methionine enkephalin was desorbed from the capillary column spray needle, loaded as a 10-μL injection of 100-amol/μL solution. The mass spectrum showed the [M + H](+) ion at m/z 574.2 with a signal-to-noise ratio of better than 5:1 from a chromatographic peak with a width of about 12 s. A narrow range (15-u) tandem mass spectrum was obtained for methionine enkephalin from the injection of 500 amol, and a full-scan tandem-mass spectrum was obtained from 50 fmol. For proteins, the average mass measurement accuracy was approximately 100-200 ppm for the injection of 2.5 fmol of apomyoglobin and 20-40 ppm for 200 fmol. Carbonic anhydrase B and bovine serum albumin showed similar mass measurement accuracies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Characterization of Peptides Bound to the Class I MHC Molecule HLA-A2.1 by Mass Spectrometry
Hunt, D. F., Henderson, R. A., Shabanowitz, J., Sakaguchi, K., Michel, H., Sevilir, N., Cox, A. L., Appella, E., & Engelhard, V. H. (1992) · Science · doi:10.1126/science.1546328 · Cited by 1,198
Kennedy, R. T., & Jorgenson, J. W. (1989) · Analytical Chemistry · doi:10.1021/ac00185a016 · Cited by 298
Electrospray: Its potential and limitations as an ionization method for biomolecules
Mann, M. (1990) · Organic Mass Spectrometry · doi:10.1002/oms.1210251104 · Cited by 225
Small volume and low flow‐rate electrospray lonization mass spectrometry of aqueous samples
Gale, D. C., & Smith, R. D. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071111 · Cited by 176
Design and performance of a novel electrospray interface
Allen, M. H., & Vestal, M. L. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)85014-b · Cited by 123
Wahl, J. H., Goodlett, D. R., Udseth, H. R., & Smith, R. D. (1992) · Analytical Chemistry · doi:10.1021/ac00048a019 · Cited by 116
Moseley, M. A., Deterding, L. J., Tomer, K. B., & Jorgenson, J. W. (1991) · Analytical Chemistry · doi:10.1021/ac00014a023 · Cited by 106
Wahl, J. H., Goodlett, D. R., Udseth, H. R., & Smith, R. D. (1993) · ELECTROPHORESIS · doi:10.1002/elps.1150140170 · Cited by 86
Cited by
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,995
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“An important development in ESI technique includes microand nano-ESI (26, 27), in which the flow rates are lowered to a nanoliter-per-minute regime to improve the method’s sensitivity.”
BackgroundMethodUltra‐high sensitivity mass spectrometry quantifies single‐cell proteome changes upon perturbation
Brunner, A., Thielert, M., Vasilopoulou, C., Ammar, C., Coscia, F., Mund, A., Hoerning, O. B., Bache, N., Apalategui, A., Lubeck, M., et al. (2022) · Molecular Systems Biology · doi:10.15252/msb.202110798 · Cited by 544
“As electrospray (ES) is concentration dependent, sensitivity increases with decreasing flow rate; however, very low flow systems are challenging to operate robustly and are consequently not widely available (Emmett & Caprioli, 1994; Wilm & Mann, 1996; Gregu (cid”
Senko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Self-citationAttomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
Gajiwala, K. S., Wu, J. C., Christensen, J., Deshmukh, G. D., Diehl, W., DiNitto, J. P., English, J. M., Greig, M. J., He, Y.-A., Jacques, S. L., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0812413106 · Cited by 391
Self-citationGatlin, C. L., Kleemann, G. R., Hays, L. G., Link, A. J., & Yates, J. R. (1998) · Analytical Biochemistry · doi:10.1006/abio.1998.2809 · Cited by 391
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
Peptides and Proteins in the Vapor Phase
Jarrold, M. F. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.179 · Cited by 361
Håkansson, K., Cooper, H. J., Emmett, M. R., Costello, C. E., Marshall, A. G., & Nilsson, C. L. (2001) · Analytical Chemistry · doi:10.1021/ac0103470 · Cited by 359
Self-citationMultichannel Microchip Electrospray Mass Spectrometry
Xue, Q., Foret, F., Dunayevskiy, Y. M., Zavracky, P. M., McGruer, N. E., & Karger, B. L. (1997) · Analytical Chemistry · doi:10.1021/ac9607119 · Cited by 341
LC/MS applications in drug development
Lee, M. S., & Kerns, E. H. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:3/4<187::aid-mas2>3.0.co;2-k · Cited by 339
Development of probe electrospray using a solid needle
Hiraoka, K., Nishidate, K., Mori, K., Asakawa, D., & Suzuki, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3201 · Cited by 328
Mass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326
Microcolumns with self-assembled particle frits for proteomics
Ishihama, Y., Rappsilber, J., Andersen, J. S., & Mann, M. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01402-4 · Cited by 323
Moini, M. (2007) · Analytical Chemistry · doi:10.1021/ac0704560 · Cited by 322
Tandem mass spectrometry in the study of fatty acids, bile acids, and steroids
Griffiths, W. J. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10046 · Cited by 287
OMICS-driven biomarker discovery in nutrition and health
Kussmann, M., Raymond, F., & Affolter, M. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2006.02.014 · Cited by 286
Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Nanoscale LC-MS(n): technical design and applications to peptide and protein analysis
Meiring, H. D., van der Heeft, E., ten Hove, G. J., & de Jong, A. P. J. M. (2002) · Journal of Separation Science · doi:10.1002/1615-9314(20020601)25:9<557::aid-jssc557>3.0.co;2-f · Cited by 267
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Analytical Chemistry · doi:10.1021/ac049848m · Cited by 261
Rizzello, C. G., Tagliazucchi, D., Babini, E., Sefora Rutella, G., Taneyo Saa, D. L., & Gianotti, A. (2016) · Journal of Functional Foods · doi:10.1016/j.jff.2016.09.023 · Cited by 250
Parent Ion Scans of Unseparated Peptide Mixtures
Wilm, M., Neubauer, G., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950875+ · Cited by 250
Håkansson, K., Chalmers, M. J., Quinn, J. P., McFarland, M. A., Hendrickson, C. L., & Marshall, A. G. (2003) · Analytical Chemistry · doi:10.1021/ac030015q · Cited by 245
Kelly, R. T., Page, J. S., Luo, Q., Moore, R. J., Orton, D. J., Tang, K., & Smith, R. D. (2006) · Analytical Chemistry · doi:10.1021/ac061133r · Cited by 240
Kujawinski, E. B., Hatcher, P. G., & Freitas, M. A. (2002) · Analytical Chemistry · doi:10.1021/ac0108313 · Cited by 236
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Srivastava, S., Chandra, A., Wang, L.-F., Seifert, W. E., DaGue, B. B., Ansari, N. H., Srivastava, S. K., & Bhatnagar, A. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.18.10893 · Cited by 222
Electrospray mass spectrometry for protein characterization
Mann, M., & Wilm, M. (1995) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(00)89019-2 · Cited by 214
Emmett, M. R., White, F. M., Hendrickson, C. L., Shi, S. D. H., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00287-0 · Cited by 211
Self-citationLarge-scale protein identification using mass spectrometry
Lin, D., Tabb, D. L., & Yates, J. R. (2003) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/s1570-9639(02)00546-0 · Cited by 210
Informatics and multiplexing of intact protein identification in bacteria and the archaea
Meng, F., Cargile, B. J., Miller, L. M., Forbes, A. J., Johnson, J. R., & Kelleher, N. L. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-952 · Cited by 208
Lanman, J., Lam, T. T., Barnes, S., Sakalian, M., Emmett, M. R., Marshall, A. G., & Prevelige, P. E. (2003) · Journal of Molecular Biology · doi:10.1016/s0022-2836(02)01245-7 · Cited by 206
Self-citationNiessen, W. M. A. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01112-6 · Cited by 206
van Baar, B. L. M. (2000) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(99)00036-4 · Cited by 197
“The nebulisation capillary may have a coaxial £ow of gas (`ionspray' [25]) or may be miniaturised for better spray performance and lower sample consumption: micro-ES [26] and nanospray [27,28].”
BackgroundHigh-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla
Schaub, T. M., Hendrickson, C. L., Horning, S., Quinn, J. P., Senko, M. W., & Marshall, A. G. (2008) · Analytical Chemistry · doi:10.1021/ac800386h · Cited by 192
Mass spectrometry in protein studies from genome to function
Roepstorff, P. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80151-6 · Cited by 189
Recent Developments in Ion Mobility Spectrometry
Borsdorf, H., Mayer, T., Zarejousheghani, M., & Eiceman, G. A. (2011) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2011.582658 · Cited by 188
“The term microelectrospray was used by Emmett and Caprioli in 1994 (197) for flows ranging from 300 to 800 nL min−1 spraying directly from a capillary needle with an inner diameter of 5 to 250 μm.”
MethodElectrospray and tandem mass spectrometry in biochemistry
GRIFFITHS, W. J., JONSSON, A. P., LIU, S., RAI, D. K., & WANG, Y. (2001) · Biochemical Journal · doi:10.1042/bj3550545 · Cited by 187
Figeys, D., Ducret, A., Yates, J. R., & Aebersold, R. (1996) · Nature Biotechnology · doi:10.1038/nbt1196-1579 · Cited by 187
Processing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Di Palma, S., Hennrich, M. L., Heck, A. J. R., & Mohammed, S. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.033 · Cited by 170
Analytical and Biochemical Perspectives of Protein O-GlcNAcylation
Ma, J., Wu, C., & Hart, G. W. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00884 · Cited by 169
Burlingame, A. L., Boyd, R. K., & Gaskell, S. J. (1996) · Analytical Chemistry · doi:10.1021/a1960021u · Cited by 169
Proteomic LC–MS systems using nanoscale liquid chromatography with tandem mass spectrometry
Ishihama, Y. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.10.107 · Cited by 168
Nanoelectrospray emitters: Trends and perspective
Gibson, G. T. T., Mugo, S. M., & Oleschuk, R. D. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20248 · Cited by 158
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Schäfer, M., Schmuck, C., Heil, M., Cooper, H. J., Hendrickson, C. L., Chalmers, M. J., & Marshall, A. G. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00576-2 · Cited by 14
Metadata
- Authors
- Emmett, M. R., & Caprioli, R. M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-07-01
- Volume
- 5
- Issue
- 7
- Pages
- 605-613
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2066486253
- Cited by
- 510
- References
- 12
- FWCI
- 15.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.