Observation of noncovalent complexes to the avidin tetramer by electrospray ionization mass spectrometry
The DOI matches its Crossref record.
Abstract
Intact avidin-biotin and avidin-biotin maleimide noncovalent complexes have been observed by electrospray ionization mass spectrometry (ESI-MS) by using an extended mass range quadrupole mass spectrometer. By utilizing mild ES1 interface conditions, the expected solution behavior of four biotin or biotin maleimide molecules noncovalently binding to each avidin tetramer can be preserved in the gas phase. The ESI-MS results show the appropriate mass additions of 973 ± 60 Da for biotin and 1802 ± 40 Da for biotin maleimide to the avidin tetramer species. These results support the hypothesis that substantial retention of higher order structure is possible in the gas phase by using gentle ESI conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 13
- 10.1007/BF01384871 · DOI · Paper page
- 10.1002/mas.1280090103 · DOI · Paper page
- 10.1021/ja00016a069 · DOI · Paper page
- 10.1002/9780470110461.ch1 · DOI · Paper page
- DeLange R. J., 1971, J. Biol. Chem., 246, 698, 10.1016/S0021-9258(18)62469-X · doi:10.1016/s0021-9258(18)62469-x
- 10.1016/S0065-3233(08)60411-8 · DOI · Paper page
- 10.1073/pnas.90.11.5076 · DOI · Paper page
- Smith, P. B.; Snyder, A. P.; Simmons, T. A.; Vestliig, M. M. Proceedings of the 41st ASMS Conference on Mass Spectrometry and Allied Topics; San Francisco, CA, May 30–June 4, 1993; p 76a.
- Kerns, E. H.; Klohr, S. E.; Volk, K. J.; Lee, M. S. Proceedings of the 41st ASMS Cortftxnce on Mass Spectronletry and Allied Topics; San Francisco, CA, May 30–June 4, 1993; p 42a.
- 10.1016/1044-0305(93)85015-P · DOI
- 10.1002/rcm.1290040305 · DOI · Paper page
- 10.1002/rcm.1290051203 · doi:10.1002/rcm.1290051203
- 10.1016/0003-2697(85)90609-8 · doi:10.1016/0003-2697(85)90609-8
Cited by
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Mass spectrometry of intact membrane protein complexes
Laganowsky, A., Reading, E., Hopper, J. T. S., & Robinson, C. V. (2013) · Nature Protocols · doi:10.1038/nprot.2013.024 · Cited by 409
Native protein mass spectrometry: from intact oligomers to functional machineries
Heuvel, R. H. V. D., & Heck, A. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.006 · Cited by 303
Metadata
- Authors
- Schwartz, B. L., Light-Wahl, K. J., & Smith, R. D.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-03-01
- Volume
- 5
- Issue
- 3
- Pages
- 201-204
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2040121478
- Cited by
- 77
- References
- 0
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Observation of noncovalent complexes to the avidin tetramer by electrospray ionization mass spectrometry. https://app.cochat.ai/papers/10.1016/1044-0305(94)85034-8
- The paper
- Schwartz, B. L., Light-Wahl, K. J., & Smith, R. D. (1994). Observation of noncovalent complexes to the avidin tetramer by electrospray ionization mass spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/1044-0305(94)85034-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.