CoChat

Effect of interference on the performance of glucose enzyme electrodes using Nafion ® coatings

Vaidya, R., Atanasov, P., Wilkins, E. · 1995 · Medical Engineering & Physics
Cited by 65

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The negatively charged perfluorinated ionomer Nafion was used as a coating on hydrogen peroxide detecting platinum electrode as well as on a polycarbonate diffusion membrane in the construction of a glucose amperometric enzyme electrode. The current response of these electrodes to hydrogen peroxide, ascorbic acid, acetaminophen, uric acid and glucose was studied and the coating procedure was optimized. It was confirmed that the Nafion coating prevents interference by anionic substances such as ascorbic acid and uric acid, and decreases acetaminophen interference. In this regard it was shown that coating the glucose diffusion membrane (polycarbonate) was more effective than coating the platinum wire itself, because of the prevention of the homogeneous redox reaction of the interference species with hydrogen peroxide, as well as the additional diffusional resistance to the glucose flux. The glucose levels in serum samples were estimated and the stability of the enzyme electrodes during continuous operation in serum was studied. An enzyme electrode with constant sensitivity of ca. 1 microA/mM and a linear range of up to 15 mM, unaffected by contact with serum, is reported.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/1350-4533(94)00006-u

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Vaidya, R., Atanasov, P., & Wilkins, E.
Venue
Medical Engineering & Physics
Published
1995-09-01
Volume
17
Issue
6
Pages
416-424
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1973333728
Cited by
65
References
1
FWCI
2.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.