Cited by 220Electrochemical sensors and biosensorsAnalytical Chemistry and SensorsAdvanced biosensing and bioanalysis techniques

A contact lens with an integrated lactate sensor

Thomas, N., Lähdesmäki, I., Parviz, B.A.·2012·Sensors and Actuators B Chemical

Integrity signals

Registry

Crossref · 10.1016/j.snb.2011.12.049

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wearable tear biosensors have been used for continuous glucose monitoring since 2007 and later for lactate sensing since 2012.

    “Wearable tear biosensors have been used for continuous glucose monitoring since 2007 [147,148,149], and later for lactate sensing since 2012 [150].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Thomas, N., Lähdesmäki, I., & Parviz, B. A.
Affiliations
University of Washington (US)
Corresponding author
Parviz, B.A.
Venue
Sensors and Actuators B Chemical
Publisher
Elsevier BV
Published
2012-02
Volume
162
Issue
1
Pages
128-134
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2013374362
Cited by
220
References
52
Citations by year
2026: 10 · 2025: 20 · 2024: 13 · 2023: 21 · 2022: 19 · 2021: 30 · 2020: 21 · 2019: 24 · 2018: 16 · 2017: 14 · 2016: 14 · 2015: 9 · 2014: 8 · 2013: 1
FWCI
2.02
Type
journal article
Language
en
Open access
closed
Locations
Sensors and Actuators B Chemical (publishedVersion)
Funders
  • National Science Foundation
  • University of Washington
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
contact lenses, lactate sensor, L-lactate, tear film, enzyme biosensor, lactate oxidase, glutaraldehyde crosslinking, bovine serum albumin, polyurethane coatings, interference suppression, in situ monitoring, platinum electrode, eye health monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review