Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
An apparatus for simultaneously monitoring heart and respiratory rates was developed using photoplethysmography (PPG) and digital filters, and compared with conventional methods. The PPG signal, which includes both heart and respiratory components, was measured at the earlobe with an original transmission mode photoplethysmographic device. A digital filtering technique was used to distinguish heart and respiratory signals from the PPG signal. The cut-off frequency of the respiratory signal filter was selected automatically depending on the heart rate. Using digital filtering techniques, heart and respiratory signals were separated at rest and during exercise. The digital signal processor was employed to realize an adaptive and real-time filtering. The heart rate was calculated by the zero-crossing method and the respiratory rate from the peak interval of the filtered signal. To evaluate the newly developed monitor, an ECG for heart rate and a transthoracic impedance plethysmogram for respiratory rate were monitored simultaneously. To obtain higher heart and respiratory rates, exercise was performed on an electrical bicycle ergometer. Heart and respiratory rates calculated by the new method compare to those obtained from ECG and the transthoracic impedance plethysmogram. The maximum error of heart and respiratory rates was 10 beats/min and 7 breaths/min, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 447 · cited 4×
“The current output sample, y(n), is given by equation (1) for the IIR and by equation (2) for the FIR filter:”
BackgroundMethodInfluentialPHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIA
DORLAS, J. C., & NIJBOER, J. A. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.5.524 · Cited by 160
Monitoring of respiratory and heart rates using a fibre-optic sensor
Lindberg, L. G., Ugnell, H., & Öberg, P. Å. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457833 · Cited by 158
Non invasive physiological measurements
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90184-3 · Cited by 120
Experimental evaluation of two new sensors for respiratory rate monitoring
Vegfors, M., Ugnell, H., Hök, B., Öberg, P. Å., & Lennmarken, C. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/2/008 · Cited by 34
Photoplethysmographic measurement of heart and respiratory rates using digital filters
Nakajima, K., TAMURA, T., Ohta, T., Miike, H., & Öberg, P. Å. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1993.978978 · Cited by 31
Self-citationThe Peripheral Pulse Monitor — A Review of Electrical Plethysmography
Sara, C. A., & Shanks, C. A. (1978) · Anaesthesia and Intensive Care · doi:10.1177/0310057x7800600309 · Cited by 14
(1970) · Andalas University Repository (Andalas University)
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“These include simple digital filtering and zero crossing detection to separate heart rate and respiratory components from the ear PPG signal (Nakajima et al 1996).”
MethodOn the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2246160 · Cited by 485
Critical review of non-invasive respiratory monitoring in medical care
Folke, M., Cernerud, L., Ekström, M., & Hök, B. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348078 · Cited by 430
Metadata
- Authors
- Nakajima, K., Tamura, T., & Miike, H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1996-07-01
- Volume
- 18
- Issue
- 5
- Pages
- 365-372
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1975267419
- Cited by
- 244
- References
- 8
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.