The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
Abstract
We present a novel method for estimating respiratory rate in real time from the photoplethysmogram (PPG) obtained from pulse oximetry. Three respiratory-induced variations (frequency, intensity, and amplitude) are extracted from the PPG using the Incremental-Merge Segmentation algorithm. Frequency content of each respiratory-induced variation is analyzed using fast Fourier transforms. The proposed Smart Fusion method then combines the results of the three respiratory-induced variations using a transparent mean calculation. It automatically eliminates estimations considered to be unreliable because of detected presence of artifacts in the PPG or disagreement between the different individual respiratory rate estimations. The algorithm has been tested on data obtained from 29 children and 13 adults. Results show that it is important to combine the three respiratory-induced variations for robust estimation of respiratory rate. The Smart Fusion showed trends of improved estimation (mean root mean square error 3.0 breaths/min) compared to the individual estimation methods (5.8, 6.2, and 3.9 breaths/min). The Smart Fusion algorithm is being implemented in a mobile phone pulse oximeter device to facilitate the diagnosis of severe childhood pneumonia in remote areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Intrathoracic Pressure on Left Ventricular Performance
Buda, A. J., Pinsky, M. R., Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L. (1979) · New England Journal of Medicine · doi:10.1056/nejm197908303010901 · Cited by 823
An Efficient Algorithm for Spectral Analysis of Heart Rate Variability
Berger, R. D., Akselrod, S., Gordon, D., & Cohen, R. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325789 · Cited by 807
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450
ThomsonChavan, J. A. (2006) · Europe PMC (PubMed Central) · doi:10.1136/adc.2006.095844 · Cited by 402
Pneumonia: the forgotten killer of children.
Wardlaw, T., Johansson, E., & Hodge, M. C. (2006) · Cited by 286
Pneumonia - The forgotten killer of children
Unicef, W. (2006) · Cited by 270
Nakajima, K., Tamura, T., & Miike, H. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00066-6 · Cited by 244
Lovett, P. B., Buchwald, J. M., Stürmann, K., & Bijur, P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.06.016 · Cited by 244
Estimation of Respiratory Rate From Photoplethysmogram Data Using Time–Frequency Spectral Estimation
Chon, K. H., Dash, S., & Ju, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2019766 · Cited by 212
Cited by
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
Metadata
- Authors
- Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-07
- Volume
- 60
- Issue
- 7
- Pages
- 1946-1953
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2124106073
- Cited by
- 485
- References
- 28
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiparameter Respiratory Rate Estimation From the Photoplethysmogram. https://app.cochat.ai/papers/10.1109/tbme.2013.2246160
- The paper
- Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A. (2013). Multiparameter Respiratory Rate Estimation From the Photoplethysmogram. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2013.2246160
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.