Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.
Abstract
Continuous computed tomographic (CT) scanning of organ volumes during a single breath hold was studied. The authors modified the table feed mechanism of a continuously rotating CT scanner to allow patient transport at low, but accurately controlled, speeds (0.1-11.0 mm/sec) during continuous 1-second scanning. An algorithm was designed to reconstruct artifact-free images for arbitrary table positions from the helical data by interpolating between adjacent scans. Section sensitivity profiles were enlarged; the section width for a 10-mm section and a speed of 10.0 mm/sec was increased by a factor of 1.3, compared with the nominal value. Clinical examples were presented for studies of lung nodules and studies enhanced with contrast medium. Major advantages are the possibility of continuous scanning of extended volumes within a breath-hold period and retrospective, arbitrary selection of anatomic levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study
Huber-Wagner, S., Lefering, R., Qvick, L.-M., Körner, M., Kay, M. V., Pfeifer, K.-J., Reiser, M., Mutschler, W., & Kanz, K.-G. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60232-4 · Cited by 890
Goldstein, S. A., Evangelista, A., Abbara, S., Arai, A., Asch, F. M., Badano, L. P., Bolen, M. A., Connolly, H. M., Cuéllar-Calàbria, H., Czerny, M., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.015 · Cited by 641
Principles of CT and CT Technology
Goldman, L. W. (2007) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.107.042978 · Cited by 445
Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Self-citationMutic, S., Palta, J. R., Butker, E. K., Das, I. J., Huq, M. S., Loo, L.-N. D., Salter, B. J., McCollough, C. H., & Van Dyk, J. (2003) · Medical Physics · doi:10.1118/1.1609271 · Cited by 344
Metadata
- Authors
- Kalender, W. A., Seissler, W., Klotz, E., & Vock, P.
- Venue
- Radiology
- Published
- 1990-07
- Volume
- 176
- Issue
- 1
- Pages
- 181-183
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2028648047
- Cited by
- 1,036
- References
- 0
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. https://app.cochat.ai/papers/10.1148/radiology.176.1.2353088
- The paper
- Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990). Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology. https://doi.org/10.1148/radiology.176.1.2353088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.