CoChat

Ultra performance liquid chromatography tandem mass spectrometry method for the measurement of anandamide in human plasma

Open access
Lam, Patricia M.W., Marczylo, Timothy H., El-Talatini, Mona, Finney, Mark, Nallendran, Vijaianitha, Taylor, Anthony H., Konje, Justin C. · 2008 · Analytical Biochemistry
Cited by 99

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Anandamide (N-arachidonoylethanolamine, AEA) is an endocannabinoid present in human plasma that is associated with several physiological functions and disease states. Significant variability in AEA plasma concentrations has been reported between studies, because quantification of AEA is fraught with methodological difficulties. A rapid, highly sensitive, robust, specific, and highly reproducible ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method is described here for the analysis of AEA in human plasma. This fully validated method using octa-deuterated AEA (AEA-d8) as an internal standard represents an improvement over previous analyses in terms of run time (4 min), limit of detection (0.055 fmol on column, 18.75 fmol/ml plasma), precision (relative standard deviations of 3.7, 3.9, and 4.8% for 1.66, 6.65, and 133 fmol on column), and accuracy (97.5-104.5%). AEA analysis was linear over the range 0.23 to 19 nM (1.66 to 133 fmol on column). To demonstrate the usefulness of this method for the measurement of AEA levels in clinical samples, plasma samples obtained from female volunteers at different stages of the menstrual cycle and pregnant women were assayed. Plasma AEA concentrations were significantly (P=0.0078) lower in the luteal phase of the menstrual cycle compared to the follicular phase. In pregnancy, the concentrations were lowest in the first and second trimesters with levels comparable to those observed in the luteal phase of the menstrual cycle and modestly increased in the third trimester. The highest plasma AEA levels were observed in women in active labour, and these were significantly (P=0.0147) higher than those observed in women at term but not in active labour. Postmenopausal women had AEA concentrations comparable to levels observed during the luteal phase of premenopausal women and were significantly (P=0.0389) lower than AEA plasma concentrations obtained during the follicular phase. The sensitivity and precision of the validated method described here suggests that this method is suitable for the analysis of AEA in clinical samples and may be utilised for the investigation of biomatrices containing limited amounts of AEA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ab.2008.05.033

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 99

Metadata

Authors
Lam, P. M. W., Marczylo, T. H., El-Talatini, M., Finney, M., Nallendran, V., Taylor, A. H., & Konje, J. C.
Venue
Analytical Biochemistry
Publisher
Elsevier BV
Published
2008-09
Volume
380
Issue
2
Pages
195-201
ISSN
0003-2697 (ISSN-L)
OpenAlex
W1966721286
Cited by
99
References
5
FWCI
6.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.