Smartphone based non-invasive salivary glucose biosensor
Abstract
The present work deals with the development of a non-invasive optical glucose biosensor using saliva samples and a smartphone. The sensor was fabricated with a simple methodology by immobilization of Glucose oxidase enzyme along with a pH responsive dye on a filter paper based strip. The strip changes color upon reaction with glucose present in saliva and the color changes were detected using a smartphone camera through RGB profiling. This standalone biosensor showed good sensitivity and low interference while operating within 20 s response time. We used various means for improvements such as the use of slope method instead of differential response; use of a responsive pH indicator and made numerous tweaks in the smartphone app. Calibration with spiked saliva samples with slopes for (R + G + B) pixels revealed an exponentially increasing calibration curve with a linear detection range of 50-540 mg/dL, sensitivity of 0.0012 pixels sec-1/mg dL-1 and LOD of 24.6 mg/dL. The biosensor was clinically validated on both healthy and diabetic subjects divided into several categories based on sex, age, diabetic status etc. and correlation between blood and salivary glucose has been established for better standardization of the sensor. Correlation of 0.44 was obtained between blood and salivary glucose in healthy individuals whereas it was 0.64 and 0.94 in case of prediabetic and diabetic patients respectively. The developed biosensor has the potential to be used for mass diagnosis of diabetes especially in such areas where people remain prohibited from routine analysis due to high healthcare cost. Apart from that, a smartphone would be the only device the user needs for this measurement, along with a disposable low cost test strip.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because saliva can be readily collected123-125, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms,126-134.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [132]
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O. H., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 316,394
IDF Diabetes Atlas: Global estimates for the prevalence of diabetes for 2015 and 2040
Ogurtsova, K., Fernandes, J. D. D. R., Huang, Y., Linnenkamp, U., Guariguata, L., Cho, N. H., Cavan, D. A., Shaw, J. E., & Makaroff, L. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.03.024 · Cited by 7,121
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 651
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373
Mobile Applications for Diabetes Self-Management: Status and Potential
El-Gayar, O., Timsina, P., Nawar, N., & Eid, W. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700130 · Cited by 370
Vashist, S. K., Schneider, E. M., & Luong, J. H. T. (2014) · Diagnostics · doi:10.3390/diagnostics4030104 · Cited by 247
Claussen, J. C., Kumar, A., Jaroch, D., Khawaja, M. H., Hibbard, A. B., Porterfield, D. M., & Fisher, T. S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200551 · Cited by 236
Barbosa, A. I., Gehlot, P., Sidapra, K., Edwards, A. D., & Reis, N. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.006 · Cited by 227
Acid Neutralizing Capacity of Human Saliva
Helm, J. F., Dodds, W. J., Hogan, W. J., Soergel, K. H., Egide, M. S., & Wood, C. M. (1982) · Gastroenterology · doi:10.1016/s0016-5085(82)80286-2 · Cited by 215
Flagged first, then by citations
1 of the 33 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Abikshyeet, 2012, Glucose estimation in the salivary secretion of diabetes mellitus patients, Diabetes, metabolic syndrome and obesity, targets Ther., 5, 149
Cited by
Sorted by citations
Items 101–143 of 143
González‐González, M., Flores-DelaToba, R., Ortiz‐Martínez, M., & Rito‐Palomares, M. (2025) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.7900 · Cited by 4
A multivariate biosensor for non-invasive glucose and urea monitoring via saliva
Singh, A. K., Panwar, S., & Jha, S. K. (2025) · RSC Advances · doi:10.1039/d5ra01018g · Cited by 4
Self-citationHEMT-Based Wearable Biosensors for Noninvasive Health Monitoring and AI-Driven Diagnostics: A Review
Das, C., & Mazumdar, K. (2025) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2025.3639676 · Cited by 4
Wells, P. K., Melman, A., Katz, E., & Smutok, O. V. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05466-4 · Cited by 4
Biosensors for glucose detection
Sehit, E., & Altıntaş, Z. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90222-9.00015-7 · Cited by 4
Bio-inspired nano-engineered strip for semiquantitative FeNO analysis
Shende, P. K., Vaidya, J., & Kulkarni, Y. A. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/ab1faf · Cited by 4
Mannino, R. G., Lopez, P., Sullivan, J., Whitson, J. D., Tumlin, J. A., Tyburski, E. A., & Lam, W. A. (2022) · medRxiv · doi:10.1101/2022.12.01.22282972 · Cited by 4
Mobile-Integrated Biosensing Technologies: State-of-the-Art Progress and Future Directions
Ganguly, A., Ali, S. A., Thakkellapati, S., Ghosh, S., Gupta, S., Teja, G. K. A., Aherwar, V., & Kapusetti, G. (2026) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.6c00233 · Cited by 3
Huang, T., Liu, G., Yu, J., Liu, M., Huang, Z., Li, J., & Li, D. (2018) · Current Analytical Chemistry · doi:10.2174/1573411014666181023112032 · Cited by 3
Non-invasive neonatal jaundice determination using smartphone camera
Anggraeni, M. D., Fatoni, A., & Rahmawati, E. (2022) · AIP conference proceedings · doi:10.1063/5.0103718 · Cited by 3
Badriah, S., Bahtiar, Y., Cahyati, P., Andang, A., & Fathurrohman, F. (2024) · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics · doi:10.35882/ijeeemi.v6i3.8 · Cited by 3
Kizilova, N. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00122 · Cited by 3
Point-of-Care Sensors in Clinical Environments
Alarcón-Ángeles, G., Álvarez‐Romero, G. A., Rosati, G., Parolo, C., & Merkoçi, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00106-0 · Cited by 3
Smartphone-based biosensors for healthcare
Shaheen, A., Qazalbash, A. A., Noor, M., Arif, M. F. M., Asim, T., Khan, W. S., & Bajwa, S. Z. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00025-9 · Cited by 2
Smartphone-based sensors for biomedical application
Borah, N., & Tamuly, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00016-8 · Cited by 2
Rajgopal, B. (2026) · Electroanalysis · doi:10.1002/elan.70167 · Cited by 2
An Abiotic Glucose Indicator System
Baingane, A., & Slaughter, G. E. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3041801 · Cited by 2
Hashemi‐Moghaddam, H., Salamat, Q., & Soylak, M. (2024) · Analytical Letters · doi:10.1080/00032719.2024.2384059 · Cited by 2
Emerging biomarkers in type 2 diabetes mellitus
Mir, R., Alghamdi, M. A. A., BinAfif, W. F., Alharthi, M. H., Alshahrani, A., Alamri, M. M. S., Alfaifi, J. A., Ameer, A., & Mir, R. (2025) · Advances in clinical chemistry · doi:10.1016/bs.acc.2025.01.002 · Cited by 3
Chen, J., Dong, X., Zhuo, D., Tang, J., Xiong, X., Luo, H., & Zou, Z. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.113675 · Cited by 2
Estimation of Neonatal Jaundice from the Chest Images Captured with a Smartphone
Anggraeni, M. D., Fatoni, A., Rahmawati, E., & Nartiningsih, I. (2022) · Advances in physics research/Advances in Physics Research · doi:10.2991/apr.k.220503.005 · Cited by 2
Goswami, R., Roy, R. K., Das, H., & Bezboruah, T. (2026) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2026.120213 · Cited by 1
Biocatalytic membrane for membrane inlet mass spectrometry
Zlámal, T., Kavcová, B., Kašparovský, T., & Červený, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-50908-1 · Cited by 1
Pereira, M. G., Brandão, T. R. S., Rangel, A. O. S. S., Mesquita, R. B. R., & Cerdà, V. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.116337 · Cited by 1
Prediction of bilirubin concentration using neonatal forehead images
Anggraeni, M. D., Fatoni, A., & Rahmawati, E. (2022) · AIP conference proceedings · doi:10.1063/5.0103722 · Cited by 1
Nanobiosensors: Construction and Diagnosis of Disease
Erkmen, C., Uslu, B., & Tığ, G. A. (2023) · Springer eBooks · doi:10.1007/978-981-19-9437-1_29 · Cited by 1
Challenges and trends in paper-based optical sensors
Sharifi, H., & Golmohammadi, H. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13356-5.00002-1 · Cited by 1
A Universal Multichannel Platform for Assembling Enzyme‐Based Boolean Logic Gates
Melman, Y., Katz, E., & Smutok, O. V. (2022) · ChemPhysChem · doi:10.1002/cphc.202200352 · Cited by 1
Glucose Monitoring Techniques and Their Calibration
Yadav, D., Singh, S. P., & Dubey, P. K. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_99 · Cited by 1
Preparation of graphene nanocomposites for anticorrosion and sensors
Promphet, N. (2018) · Chula Digiverse · doi:10.58837/chula.the.2018.371 · Cited by 1
Sandoval-Palomares, J. D. J., & Yáñez-Mendiola, J. (2019) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2019.05.00167
A wireless self-powered glucose monitoring biosystem
Baingane, A., & Slaughter, G. E. (2020) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems50311.2020.9265568
Measurement in biological fluids
Patel, B. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-821203-5.00002-6
A review of noninvasive methods applied in diabetes management and treatment
Rydosz, A. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-99887-1.00004-2
Xu, W., Long, T., Ouyang, M., Peng, C., Luo, H., Xu, D. Y., & Lin, Q. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4195261
Aroutiounian, V. M. (2022) · Armenian Journal of Physics · doi:10.54503/18291171-2022.15.4-131
Cavitas Biosensors (Body Cavity Sensors)
Arakawa, T., Iitani, K., Toma, K., & Mitsubayashi, K. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_1
Nanoscale sensors for monitoring of human health
Chawla, S., Shashikumar, U., & Hussain, C. M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-90254-0.00008-8
Highly Protein-resistant AuNPs-ampholytes Modified Boric Acid Hydrogel for Saliva Glucose Detection
Dou, Q., Chen, T., Liping, Z., Qing, D., & Hu, D. (2025) · Open Journal of Analytical and Bioanalytical Chemistry · doi:10.17352/ojabc.000033
Deng, J., Xu, Y., Li, C., & Wang, L. (2025) · Research Square · doi:10.21203/rs.3.rs-7331923/v1
Bioelectronic Devices for Diabetes: Monitoring, Management, and Precision Health
Mahato, K., & Kummari, S. (2025) · Springer eBooks · doi:10.1007/978-981-95-2117-3_8
Chaurasia, A., Kumar, H., Banik, O., Perumal, A. S., Ganesan, S., Haldavnekar, R., Kumar, P., & Banoth, E. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3682263
Ren, Q., Zhang, C., Li, H., Xie, L., Sun, X., & Liu, Q. (2026) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2026.101230
Metadata
- Authors
- Soni, A., & Jha, S. K.
- Affiliations
- All India Institute of Medical Sciences (IN)
- Corresponding author
- Jha, Sandeep Kumar
- ORCID
- Jha, Sandeep Kumar
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 996
- Pages
- 54-63
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2766873441
- Cited by
- 143
- References
- 33
- Citations by year
- 2026: 7 · 2025: 22 · 2024: 9 · 2023: 13 · 2022: 30 · 2021: 11 · 2020: 25 · 2019: 18 · 2018: 8
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Indian Institute of Technology Delhi
- Indian Council of Medical Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- salivary glucose, smartphone sensing, glucose oxidase, pH-responsive dyes, colorimetric sensing, diabetes diagnosis, disposable test strip, low-cost diagnostics
- MeSH terms
- Smartphone, Adult, Aged, Aged, 80 and over, Diabetes Mellitus, Enzymes, Immobilized, Female, Glucose, Glucose Oxidase, Humans, Male, Middle Aged, Saliva, Biosensing Techniques, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review