The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
Smartphone based non-invasive salivary glucose biosensor
Abstract
The present work deals with the development of a non-invasive optical glucose biosensor using saliva samples and a smartphone. The sensor was fabricated with a simple methodology by immobilization of Glucose oxidase enzyme along with a pH responsive dye on a filter paper based strip. The strip changes color upon reaction with glucose present in saliva and the color changes were detected using a smartphone camera through RGB profiling. This standalone biosensor showed good sensitivity and low interference while operating within 20 s response time. We used various means for improvements such as the use of slope method instead of differential response; use of a responsive pH indicator and made numerous tweaks in the smartphone app. Calibration with spiked saliva samples with slopes for (R + G + B) pixels revealed an exponentially increasing calibration curve with a linear detection range of 50-540 mg/dL, sensitivity of 0.0012 pixels sec-1/mg dL-1 and LOD of 24.6 mg/dL. The biosensor was clinically validated on both healthy and diabetic subjects divided into several categories based on sex, age, diabetic status etc. and correlation between blood and salivary glucose has been established for better standardization of the sensor. Correlation of 0.44 was obtained between blood and salivary glucose in healthy individuals whereas it was 0.64 and 0.94 in case of prediabetic and diabetic patients respectively. The developed biosensor has the potential to be used for mass diagnosis of diabetes especially in such areas where people remain prohibited from routine analysis due to high healthcare cost. Apart from that, a smartphone would be the only device the user needs for this measurement, along with a disposable low cost test strip.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because saliva can be readily collected123-125, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms,126-134.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [132]
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O. H., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 316,394
IDF Diabetes Atlas: Global estimates for the prevalence of diabetes for 2015 and 2040
Ogurtsova, K., Fernandes, J. D. D. R., Huang, Y., Linnenkamp, U., Guariguata, L., Cho, N. H., Cavan, D. A., Shaw, J. E., & Makaroff, L. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.03.024 · Cited by 7,121
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 651
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373
Mobile Applications for Diabetes Self-Management: Status and Potential
El-Gayar, O., Timsina, P., Nawar, N., & Eid, W. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700130 · Cited by 370
Vashist, S. K., Schneider, E. M., & Luong, J. H. T. (2014) · Diagnostics · doi:10.3390/diagnostics4030104 · Cited by 247
Claussen, J. C., Kumar, A., Jaroch, D., Khawaja, M. H., Hibbard, A. B., Porterfield, D. M., & Fisher, T. S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200551 · Cited by 236
Barbosa, A. I., Gehlot, P., Sidapra, K., Edwards, A. D., & Reis, N. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.006 · Cited by 227
Acid Neutralizing Capacity of Human Saliva
Helm, J. F., Dodds, W. J., Hogan, W. J., Soergel, K. H., Egide, M. S., & Wood, C. M. (1982) · Gastroenterology · doi:10.1016/s0016-5085(82)80286-2 · Cited by 215
Flagged first, then by citations
1 of the 33 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Abikshyeet, 2012, Glucose estimation in the salivary secretion of diabetes mellitus patients, Diabetes, metabolic syndrome and obesity, targets Ther., 5, 149
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 338
Recent Developments in Biomarkers for Diagnosis and Screening of Type 2 Diabetes Mellitus
Ortiz‐Martínez, M., González‐González, M., Martagón, A. J., Hlavinka, V., Willson, R. C., & Rito‐Palomares, M. (2022) · Current Diabetes Reports · doi:10.1007/s11892-022-01453-4 · Cited by 241
Recent trends in smartphone-based detection for biomedical applications: a review
Banik, S., Melanthota, S. K., Arbaaz, Vaz, J. M., Kadambalithaya, V. M., Hussain, I., Dutta, S., & Mazumder, N. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03184-z · Cited by 176
Smartphone based optical biosensor for the detection of urea in saliva
Soni, A., Surana, R. K., & Jha, S. K. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.04.108 · Cited by 170
Self-citationCao, L., Han, G., Xiao, H., Chen, Z., & Cheng, F. J. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.10.049 · Cited by 161
Hu, S., Jiang, Y., Wu, Y., Guo, X., Ying, Y., Wen, Y., & Yang, H. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c12988 · Cited by 146
Non-invasive wearable chemical sensors in real-life applications
Promphet, N., Ummartyotin, S., Ngeontae, W., Puthongkham, P., & Rodthongkum, N. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338643 · Cited by 141
Non-enzymatic and non-invasive glucose detection using Au nanoparticle decorated CuO nanorods
Chakraborty, P., Dhar, S., Debnath, K., Majumder, T., & Mondal, S. P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.086 · Cited by 134
Smart biosensors and intelligent devices for salivary biomarker detection
Zheng, X., Zhang, F., Wang, K., Zhang, W., Li, Y., Sun, Y. L., Sun, X., Li, C., Dong, B., Wang, L., et al. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116281 · Cited by 126
Ilea, A., Andrei, V., Feurdean, C. N., Băbțan, A.-M., Petrescu, N. B., Câmpian, R. S., Boşca, A. B., Ciui, B., Tertiş, M., Săndulescu, R., et al. (2019) · Biosensors · doi:10.3390/bios9010027 · Cited by 114
Kap, Ö., Kılıç, V., Hardy, J. G., & Horzum, N. (2021) · The Analyst · doi:10.1039/d0an02031a · Cited by 111
Upadhyay, S., Kumar, A., Srivastava, M., Srivastava, A., Dwivedi, A., Singh, R. K., & Srivastava, S. (2024) · Talanta · doi:10.1016/j.talanta.2024.126080 · Cited by 106
Reddy, V. S., Agarwal, B., Ye, Z., Zhang, C., Roy, K., Chinnappan, A., Narayan, R. J., Ramakrishna, S., & Ghosh, R. (2022) · Nanomaterials · doi:10.3390/nano12071082 · Cited by 99
Electrochemical vs. Optical Biosensors for Point-of-Care Applications: A Critical Review
Pour, S. R. S., Calabria, D., Emamiamin, A., Lazzarini, E., Pace, A., Guardigli, M., Zangheri, M., & Mirasoli, M. (2023) · Chemosensors · doi:10.3390/chemosensors11100546 · Cited by 97
Lee, T., Kim, I., Cheong, D. Y., Roh, S., Jung, H. G., Lee, S. W., Kim, H. S., Yoon, D. S., Hong, Y., & Lee, G. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338387 · Cited by 75
Fu, Q., Zhang, C., Xie, J., Li, Z., Qu, L., Cai, X., Ouyang, H. X., Song, Y., Du, D., Lin, Y., et al. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.09.059 · Cited by 64
Luo, Y., Wang, Q., Li, J., Xu, F., Sun, L., Bu, Y., Zou, Y., Kraatz, H., & Rosei, F. (2020) · Inorganic Chemistry Frontiers · doi:10.1039/d0qi00104j · Cited by 63
Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids
Falk, M., Psotta, C., Cirovic, S., & Shleev, S. (2020) · Sensors · doi:10.3390/s20216352 · Cited by 62
Jędrzak, A., Kuznowicz, M., Rębiś, T., & Jesionowski, T. (2022) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2022.108071 · Cited by 59
Yuan, Y., Wang, Y., Wang, H., & Hou, S. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113495 · Cited by 59
Noninvasive glucose detection in exhaled breath condensate
Tankasala, D., & Linnes, J. C. (2019) · Translational research · doi:10.1016/j.trsl.2019.05.006 · Cited by 54
Abdelbasset, W. K., Savina, S. V., Mavaluru, D., SHICHIYAKH, R. A., Bokov, D. O., & Mustafa, Y. F. (2022) · Talanta · doi:10.1016/j.talanta.2022.123769 · Cited by 54
Kalasin, S., Sangnuang, P., Khownarumit, P., Tang, I. M., & Surareungchai, W. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00864 · Cited by 53
Hasan, M. K., Aziz, M. H., Zarif, M. I. I., Hasan, M., Hashem, M. M. A., Guha, S., Love, R. R., & Ahamed, S. I. (2020) · JMIR mhealth and uhealth · doi:10.2196/16806 · Cited by 52
Moving toward smart biomedical sensing
Naghdi, T., Ardalan, S., Adib, Z. A., Sharifi, A. R., & Golmohammadi, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.115009 · Cited by 52
Biosensing Technologies for Medical Applications, Manufacturing, and Regenerative Medicine
Shafiee, A., Ghadiri, E., Kassis, J. N., Zarandi, N. P., & Atala, A. (2018) · Current Stem Cell Reports · doi:10.1007/s40778-018-0123-y · Cited by 51
Non-invasive, ultrasensitive detection of glucose in saliva using metal oxide transistors
Sharma, A., AlGhamdi, W. S., Faber, H. A., Lin, Y., Liu, C., Hsu, E.-K., Lin, W., Naphade, D. R., Mandal, S. K., Heeney, M., et al. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115448 · Cited by 51
Singh, A. K., & Jha, S. K. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2920296 · Cited by 50
Self-citationKhachornsakkul, K., Rybicki, F. J., & Sonkusale, S. (2023) · Talanta · doi:10.1016/j.talanta.2023.124538 · Cited by 46
Recent Advances in Smart Phone-Based Biosensors for Various Applications
Xing, E., Chen, H., Xin, X., Cui, H., Dou, Y., & Song, S. (2025) · Chemosensors · doi:10.3390/chemosensors13070221 · Cited by 47
Color changing sensors: A multimodal system for integrated screening
Shende, P. K., Prabhakar, B. R., & Patil, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115687 · Cited by 45
Golap, M. A.-U., Raju, S. M. T. U., Haque, M. R., & Hashem, M. M. A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102478 · Cited by 43
Rajasulochana, P., Ganesan, Y., Kumar, P. S., Mahalaxmi, S., Tasneem, S., Ponnuchamy, M., & Kapoor, A. (2022) · Environmental Research · doi:10.1016/j.envres.2022.112745 · Cited by 43
Microneedle-Based Glucose Sensor Platform: From Vitro to Wearable Point-of-Care Testing Systems
Ju, J., Li, L., Regmi, S., Zhang, X., & Tang, S. (2022) · Biosensors · doi:10.3390/bios12080606 · Cited by 42
Breath-based biosensors and system development for noninvasive detection of diabetes: A review
Jadhav, M. R., Wankhede, P. R., Srivastava, S., Bhargaw, H. N., & Singh, S. (2023) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2023.102931 · Cited by 42
Saeed, A. A., Abbas, M. N., Singh, B., ABOUZEID, R. E., & Kamel, S. M. (2019) · Analytical Methods · doi:10.1039/c9ay02176k · Cited by 42
Fabrication of porous silicon based label-free optical biosensor for heat shock protein 70 detection
Maniya, N. H., & Srivastava, D. N. (2020) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2020.105126 · Cited by 42
Promphet, N., Thanawattano, C., Buekban, C., Laochai, T., Rattanawaleedirojn, P., Siralertmukul, K., Potiyaraj, P., Hinestroza, J. P., & Rodthongkum, N. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202101684 · Cited by 41
Smartphone-Based Electrochemical Systems for Glucose Monitoring in Biofluids: A Review
Xu, J., Yan, Z., & Liu, Q. (2022) · Sensors · doi:10.3390/s22155670 · Cited by 42
Estimation of trace-mercury concentration in water using a smartphone
Hatiboruah, D., Das, T., Chamuah, N., Rabha, D., Talukdar, B., Bora, U., Ahamad, K. U., & Nath, P. (2020) · Measurement · doi:10.1016/j.measurement.2020.107507 · Cited by 40
Dou, Q., Zhang, Z., Wang, Y., Wang, S., Hu, D., Zhao, Z., Liu, H., & Dai, Q. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c08229 · Cited by 39
Proteomic advances in salivary diagnostics.
Pappa, E., Vougas, K., Zoidakis, J., & Vastardis, H. (2020) · Biochimica et Biophysica Acta - Proteins and Proteomics · doi:10.1016/j.bbapap.2020.140494 · Cited by 35
Bibliometric Analysis and Methodological Review of Mobile Health Services and Applications in India
Pai, R. R., & Alathur, S. (2021) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2020.104330 · Cited by 35
Survey of Saliva Components and Virus Sensors for Prevention of COVID-19 and Infectious Diseases
Dave, P., Rojas‐Cessa, R., Dong, Z., & Umpaichitra, V. (2020) · Biosensors · doi:10.3390/bios11010014 · Cited by 35
Fan, B., Wu, Y., Guo, H., Yu, F., Liu, L.-E., Yu, S., Wang, J., & Wang, Y. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342852 · Cited by 34
Smartphone-based image analysis coupled to paper-based colorimetric devices
Kim, D., Kim, S., Ha, H.-T., & Kim, S. (2020) · Current Applied Physics · doi:10.1016/j.cap.2020.06.021 · Cited by 29
Vidal, E., Lorenzetti, A. S., García, C. D., & Domini, C. E. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338249 · Cited by 28
Gholamalizadeh, N., Mazinani, S., Abdouss, M., Bazargan, A. M., & Fatemi, F. (2022) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.107083 · Cited by 28
Geldsetzer, P., Flores, S., Wang, G., Flores, B. E. I., Rogers, A. B., Bunker, A., Chang, A. Y., & Tisdale, R. L. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00644-3 · Cited by 29
Dou, Q., Wang, S., Zhang, Z., Wang, Y., Zhao, Z., Guo, H., Liu, H., & Dai, Q. (2020) · Nanoscale · doi:10.1039/d0nr03193c · Cited by 26
Development of an amperometric biosensor on a toothbrush for glucose
Liu, Y., Yue, W., & Cui, Y. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100133 · Cited by 26
Ortiz‐Martínez, M., Flores-DelaToba, R., González‐González, M., & Rito‐Palomares, M. (2021) · Biosensors · doi:10.3390/bios11120482 · Cited by 25
A Chemometric-Assisted Colorimetric-Based Inexpensive Paper Biosensor for Glucose Detection
Kishnani, V., Kumari, S., & Gupta, A. (2022) · Biosensors · doi:10.3390/bios12111008 · Cited by 25
Nanosensors for Therapeutic Drug Monitoring: Implications for Transplantation
Shafiee, A., Ghadiri, E., Kassis, J. N., & Atala, A. (2019) · Nanomedicine · doi:10.2217/nnm-2019-0150 · Cited by 25
Tandem Quantification of Multiple Carbohydrates in Saliva Using Surface-Enhanced Raman Spectroscopy
Lin, D., Yang, S.-W., Hsieh, C.-L., Hsu, K.-J., Gong, T., Wu, Q., Qiu, S., Feng, S., & Kong, K. V. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02533 · Cited by 24
Salivary glucose measurement: A holy ground for next generation of non-invasive diabetic monitoring
Ko, A., & Liao, C. (2023) · Hybrid Advances · doi:10.1016/j.hybadv.2023.100052 · Cited by 24
A miniature CuO nanoarray sensor for noninvasive detection of trace salivary glucose
Yang, J., Chen, H., Zhu, C., Huang, Z., Ou, R., Gao, S., & Yang, Z. (2022) · Analytical Biochemistry · doi:10.1016/j.ab.2022.114857 · Cited by 23
Panwar, S., Sarkar, P., Kasim, D. S., Anand, R., Priya, A., Prakash, S., & Jha, S. K. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100452 · Cited by 22
Self-citationWide-field multi-modal microscopic imaging using smartphone
Rabha, D., Biswas, S., Chamuah, N., Mandal, M., & Nath, P. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106343 · Cited by 22
Lanzalaco, S., Fabregat, G., Muñoz-Galán, H., Cabrera, J., Muñoz-Pascual, X., Llorca, J., & Alemán, C. (2020) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.0c03545 · Cited by 21
gluCam: Smartphone Based Blood Glucose Monitoring and Diabetic Sensing
Ghosal, S., Kumar, A., Udutalapally, V., & Das, D. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3116191 · Cited by 19
Molecularly imprinted polymer-based biosensor for detection of salivary glucose in diabetes
Vaidya, A., Sahoo, J., & Shende, P. K. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.125219 · Cited by 19
Skonta, A., Bellou, M. G., Matikas, T. E., & Stamatis, H. (2024) · Biosensors · doi:10.3390/bios14060299 · Cited by 18
Optical blood glucose non-invasive detection and its research progress
Peng, Z., & Yang, Z. (2024) · The Analyst · doi:10.1039/d4an01048e · Cited by 18
Integrated paper-based sensing devices for diagnostic applications
Brunauer, A., Ates, H. C., Dincer, C., & Früh, S. M. (2020) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2020.03.003 · Cited by 18
Modern noninvasive methods for monitoring glucose levels in patients: a review
Dziergowska, K., Łabowska, M. B., Gąsior‐Głogowska, M., Kmiecik, B., & Detyna, J. D. (2019) · Bio-Algorithms and Med-Systems · doi:10.1515/bams-2019-0052 · Cited by 18
Immobilization of glucose oxidase on plasma-treated polyethylene for non-invasive glucose detection
Fabregat, G., Lanzalaco, S., Saïd, J. A., Muñoz-Pascual, X., Llorca, J., & Alemán, C. (2021) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2021.115509 · Cited by 17
Revisiting the Use of Biological Fluids for Noninvasive Glucose Detection
Zhao, M., & Leung, P. S. (2020) · Future Medicinal Chemistry · doi:10.4155/fmc-2020-0019 · Cited by 16
Review of point-of-care platforms for diabetes: (1) sensing
Liu, Y., Luo, X., Yu, Q., Ye, L., Yang, L., & Cui, Y. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100113 · Cited by 19
Clinical Evaluation of a Photonic Crystal Sensor for Glucose Monitoring in Urine
Lan, Y., Xue, M., Qiu, L., & Meng, Z. (2019) · ChemistrySelect · doi:10.1002/slct.201900840 · Cited by 16
A Smart Tongue Depressor-Based Biosensor for Glucose
Luo, X., Shi, W., Liu, Y., Sha, P., Chu, Y., & Cui, Y. (2019) · Sensors · doi:10.3390/s19183864 · Cited by 16
Advances in point-of-care testing based on microfluidic chips towards small molecular biomarkers
Hu, W., Zhao, Y. C., Qi, H., Sun, H., Xie, Y., Wang, Y., & Liang, Q. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118596 · Cited by 14
NFC-enabled photothermal-based microfluidic paper analytical device for glucose detection
Khachornsakkul, K., Del‐Rio‐Ruiz, R., Asci, C., & Sonkusale, S. (2024) · The Analyst · doi:10.1039/d4an00506f · Cited by 14
Ekawita, R., Nasution, A. A., Yuliza, E., Suardi, N., & Suwarsono, S. (2020) · Jurnal Penelitian Fisika dan Aplikasinya (JPFA) · doi:10.26740/jpfa.v10n2.p103-113 · Cited by 14
Saliva sampling strategies affecting the salivary glucose measurement
Qian, X., Ko, A. S. M., Li, H., & Liao, C. (2023) · Analytical Methods · doi:10.1039/d3ay01005h · Cited by 13
Data Reliability and Quality in Body Area Networks for Diabetes Monitoring
Huzooree, G., Khedo, K. K., & Joonas, N. (2018) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-00865-9_4 · Cited by 13
Microfluidic Technologies Using Oral Factors: Saliva-Based Studies
Masooleh, H. S., Ghavami‐Lahiji, M., Ciancio, A., & Tayebi, L. (2019) · Springer eBooks · doi:10.1007/978-3-030-21583-5_16 · Cited by 13
Çelik, H., Caf, B. B., & Çebi, G. (2025) · Chemical Papers · doi:10.1007/s11696-025-04319-7 · Cited by 12
Electrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 12
Chemiluminescence methods for glucose determination: A guiding light for diabetes management
Iranifam, M. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118316 · Cited by 11
Martins, L., Silva, A. F. D. S., de Moraes, L. M. B., Gonçalves, I. C., de Godoy, B. B. R., & Rocha, F. R. P. (2020) · International Electronic Conference on Foods (Foods) · doi:10.3390/foods_2020-07655 · Cited by 11
A biosensor based on a thermal camera using infrared radiance as the signal probe
Jiao, F., Cao, F., Gao, Y., Shuang, F., & Dong, D. (2022) · Talanta · doi:10.1016/j.talanta.2022.123453 · Cited by 11
A smartphone-based photometric and fluorescence sensing for accurate estimation of zinc ion in water
Hatiboruah, D., Biswas, S., Sarma, D., & Nath, P. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113586 · Cited by 11
Mashhadizadeh, M. H., & Abdollahi, G. (2023) · ChemistrySelect · doi:10.1002/slct.202204359 · Cited by 11
Mannino, R. G., Sullivan, J., Frediani, J. K., George, P. E., Whitson, J. D., Tumlin, J. A., Lyon, L. A., Tyburski, E. A., & Lam, W. A. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2424677122 · Cited by 10
Kimura, H., & Asano, R. (2022) · Analytical Biochemistry · doi:10.1016/j.ab.2022.114806 · Cited by 10
A Glucose Monitoring System With Remote Data Access
Baingane, A., & Slaughter, G. E. (2020) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2020.3002453 · Cited by 9
Melman, Y., Wells, P. K., Katz, E., & Smutok, O. V. (2022) · Talanta · doi:10.1016/j.talanta.2022.123325 · Cited by 9
Fully inkjet-printed glucose assay fabricated on highly porous pigment coating
Jutila, E., Koivunen, R., Bollström, R., & Gane, P. A. C. (2020) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-02344-4 · Cited by 8
Development of a palm-sized bioelectronic sensing device for protein detection in milk samples
Mahapatra, S., & Chandra, P. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.123132 · Cited by 8
de Santana, P. C., & Lourenço, F. R. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104626 · Cited by 7
Xu, W., Ouyang, M., Luo, H., Xu, D., & Lin, Q. (2022) · New Journal of Chemistry · doi:10.1039/d2nj03107h · Cited by 7
A non-invasive device for glucose monitoring through saliva – a paradigm shift in diabetes care
Panwar, S., Kasim, D. S., Singh, H., Priya, A., Deepak, K. K., Prakash, S., & Jha, S. K. (2025) · Sensors & Diagnostics · doi:10.1039/d5sd00027k · Cited by 6
Self-citationGlucose Monitoring Techniques and Their Calibration
Yadav, D., Singh, S. P., & Dubey, P. K. (2023) · Springer eBooks · doi:10.1007/978-981-19-1550-5_99-1 · Cited by 7
Artigues, M., Oh, S., Gilabert‐Porres, J., Abellà, J., Borrós, S., & Colominas, S. (2018) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2018.11.076 · Cited by 6
Fang, Y., Ning, J., Tang, Z., Hu, T., Zhu, T., Wang, F. R., Wang, C., Shen, X., & Chong, Y. (2025) · Nano Research · doi:10.26599/nr.2025.94907984 · Cited by 5
Sharma, V., Kapil, D., & Singh, B. (2024) · Process Biochemistry · doi:10.1016/j.procbio.2024.11.023 · Cited by 5
A Saliva-Based Noninvasive Point-of-Care Glucometer
Panwar, S., Aasarey, R., Anand, R., Priya, A., Prakash, S., & Jha, S. K. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3536293 · Cited by 5
Self-citationPalladium‐Based Nanozymes: From Synthesis and Activity Modulation to Biomedical Applications
Fang, Y., Liu, Y., Tang, Z., Zhang, Z., Yang, X., Li, X., Zhao, L., & Chong, Y. (2026) · Chemistry - A European Journal · doi:10.1002/chem.202503589 · Cited by 4
Metadata
- Authors
- Soni, A., & Jha, S. K.
- Affiliations
- All India Institute of Medical Sciences (IN)
- Corresponding author
- Jha, Sandeep Kumar
- ORCID
- Jha, Sandeep Kumar
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 996
- Pages
- 54-63
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2766873441
- Cited by
- 143
- References
- 33
- Citations by year
- 2026: 7 · 2025: 22 · 2024: 9 · 2023: 13 · 2022: 30 · 2021: 11 · 2020: 25 · 2019: 18 · 2018: 8
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Indian Institute of Technology Delhi
- Indian Council of Medical Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- salivary glucose, smartphone sensing, glucose oxidase, pH-responsive dyes, colorimetric sensing, diabetes diagnosis, disposable test strip, low-cost diagnostics
- MeSH terms
- Smartphone, Adult, Aged, Aged, 80 and over, Diabetes Mellitus, Enzymes, Immobilized, Female, Glucose, Glucose Oxidase, Humans, Male, Middle Aged, Saliva, Biosensing Techniques, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review