The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Influence of the fiber diameter and surface roughness of electrospun vascular grafts on blood activation
Open accessAbstract
Electrospun grafts have been widely investigated for vascular graft replacement due to their ease and compatibility with many natural and synthetic polymers. Here, the effect of the processing parameters on the scaffold's architecture and subsequent reactions of partially heparinized blood triggered by contacting these topographies were studied. Degrapol® (DP) and poly(lactic-co-glycolic acid) (PLGA) electrospun fibrous scaffolds were characterized with regard to fiber diameter, pore area and scaffold roughness. The study showed that electrospinning parameters greatly affect fiber diameter together with pore dimension and overall scaffold roughness. Coagulation cascade activation, early platelet adhesion and activation were analyzed after 2h of exposure of blood to the biomaterials. While no differences were found between DP and PLGA with similar topographies, the blood reactions were observed to be dependent on the fiber diameter and scaffold roughness. Scaffolds composed of thin fibers (diameter <1μm) triggered very low coagulation and almost no platelets adhered. On the other hand, scaffolds with a bigger fiber diameter (2-3μm) triggered higher thrombin formation and more platelets adhered. The highest platelet adhesion and activations rates as well as coagulation cascade activation were found in blood incubated in contact with the scaffolds produced with the biggest fiber diameter (5μm). These findings indicate that electrospun grafts with small fiber diameter (<1μm) could perform better with reduced early thrombogenicity due to lower platelet adhesion and lower activation of platelets and coagulation cascade.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keun Kwon, I., Kidoaki, S., & Matsuda, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.007 · Cited by 607
Controlling the porosity of fibrous scaffolds by modulating the fiber diameter and packing density
Soliman, S., Sant, S., Nichol, J. W., Khabiry, M., Traversa, E., & Khademhosseini, A. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33010 · Cited by 305
Cited by
Adeli, H., Khorasani, M. T., & Parvazinia, M. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.10.115 · Cited by 512
Design Challenges in Polymeric Scaffolds for Tissue Engineering
Echeverria Molina, M. I., Malollari, K. G., & Komvopoulos, K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.617141 · Cited by 397
Polymeric scaffolds in tissue engineering: a literature review
Jafari, M., Paknejad, Z., Rad, M. R., Motamedian, S. R., Eghbal, M. J., Nadjmi, N., & Khojasteh, A. (2017) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33547 · Cited by 296
Hernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 259
Radke, D., Jia, W., Sharma, D., Fena, K., Wang, G., Goldman, J., & Zhao, F. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701461 · Cited by 256
Metadata
- Authors
- Milleret, V., Hefti, T., Hall, H., Vogel, V., & Eberli, D.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2012-12
- Volume
- 8
- Issue
- 12
- Pages
- 4349-4356
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2074949711
- Cited by
- 227
- References
- 2
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of the fiber diameter and surface roughness of electrospun vascular grafts on blood activation. https://app.cochat.ai/papers/10.1016/j.actbio.2012.07.032
- The paper
- Milleret, V., Hefti, T., Hall, H., Vogel, V., & Eberli, D. (2012). Influence of the fiber diameter and surface roughness of electrospun vascular grafts on blood activation. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2012.07.032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.