Peptide LL-37 coating on micro-structured titanium implants to facilitate bone formation in vivo via mesenchymal stem cell recruitment
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Titanium (Ti) and Ti-alloys were widely used in clinic orthopedics, however, the insufficient bone formation surrounding Ti-based implants still limited their biological performances. Surface modification of Ti substrates is essential to improve their interactions with bone-forming cells and bone tissue. In this study, we modified Ti substrates by coating peptide LL-37 onto micro-structured Ti substrates and aimed to (i) induce mesenchymal stem cells (MSCs) migration both in vitro and in vivo, (ii) facilitate osteogenic differentiation of MSCs and new bone formation. The surface micro-structured Ti substrates with hydroxyapatite deposition were fabricated by a two-step method including micro-arc oxidation (MAO) and hydrothermal treatment. LL-37 was loaded on micro-structured Ti substrates with the assistance of polydopamine coating. We confirmed that surface-modified Ti substrates benefited viability, adhesion, migration and osteogenic differentiation of MSCs in vitro. In a femur-defect rat model, the surface-modified Ti implants effectively induced CD29+/CD90+ positive cells migration in one week after implantation. According to the results of H&E, Masson's trichrome staining and immunohistochemical staining of OCN, OPN and collagen I, the targeted Ti implants exhibited significant new bone formation after implantation for 4 weeks. These results indicate that the surface modification of Ti samples facilitated bone formation through MSCs recruitment. STATEMENT OF SIGNIFICANCE: The inherent surface bioinertness of titanium (Ti) and Ti-alloys still limits their biological performances in clinical applications. Recently, the strategy of mesenchymal stem cells (MSCs) recruitment has been proposed to improve the osteointegration of bone implants. Herein, we reports the surface modification of Ti implants from the point of MSCs recruitment. Peptide LL-37 was coated on micro-structured Ti substrates to (i) recruit MSCs, (ii) regulate bio-physiological performance of MSCs, and (iii) facilitate bone formation in vivo. Our results improve the understanding of the interaction between Ti implants and MSCs, and provide a promising strategy of MSCs recruitment in the design of bone repair related biomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Caplan, A. I., & Correa, D. (2011) · Cell Stem Cell · doi:10.1016/j.stem.2011.06.008 · Cited by 1,682
Chromek, M., Slamová, Z., Bergman, P., Kovács, L., Podracká, L., Ehrén, I., Hökfelt, T., Gudmundsson, G. H., Gallo, R. L., Agerberth, B., et al. (2006) · Nature Medicine · doi:10.1038/nm1407 · Cited by 652
How mesenchymal stem cells interact with tissue immune responses
Shi, Y., Su, J., Roberts, A. I., Shou, P., Rabson, A. B., & Ren, G. (2012) · Trends in Immunology · doi:10.1016/j.it.2011.11.004 · Cited by 633
Developing a pro-regenerative biomaterial scaffold microenvironment requires T helper 2 cells
Sadtler, K., Estrellas, K., Allen, B. W., Wolf, M. T., Fan, H., Tam, A. J., Patel, C. H., Luber, B. S., Wang, H., Wagner, K. R., et al. (2016) · Science · doi:10.1126/science.aad9272 · Cited by 605
Bai, L., Du, Z., Du, J., Yao, W., Zhang, J., Weng, Z., Liu, S., Zhao, Y., Liu, Y., Zhang, X., et al. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.010 · Cited by 265
Cited by
Combating Implant Infections: Shifting Focus from Bacteria to Host
Amin Yavari, S., Castenmiller, S. M., van Strijp, J. A. G., & Croes, M. (2020) · Advanced Materials · doi:10.1002/adma.202002962 · Cited by 257
Tao, B., Zhao, W., Lin, C., Yuan, Z., He, Y., Lu, L., Chen, M., Ding, Y., Yang, Y., Xia, Z., et al. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124621 · Cited by 206
Self-citationLu, G., Xu, Y., Liu, Q., Chen, M., Sun, H., Wang, P., Li, X., Wang, Y., Li, X., Hui, X., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-30243-5 · Cited by 185
Self-citationPolydopamine-Modified functional materials promote bone regeneration
Wang, J., Cui, Y., Zhang, B., Sun, S., Xu, H., Yao, M., Wu, D., & Wang, Y. (2024) · Materials & Design · doi:10.1016/j.matdes.2024.112655 · Cited by 56
Antimicrobial peptides for bone tissue engineering: Diversity, effects and applications
Hao, Z., Chen, R., Chai, C., Wang, Y., Chen, T., Li, H., Hu, Y., Feng, Q., & Li, J. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1030162 · Cited by 47
Zhang, M., Mi, M., Hu, Z., Li, L., Chen, Z., Gao, X., Liu, D., Xu, B., & Liu, Y. (2024) · Drug Design, Development and Therapy · doi:10.2147/dddt.s473007 · Cited by 31
“78 PDA-modified titanium (Ti) substrates enhance the viability, adhesion, migration, and osteogenic differentiation of MSCs. 79 Additionally, biofunctionalized TiO 2 /MoS 2 /PDA nanotube coatings on Ti implants have been developed to stimulate osteogenic activity, notably through the simulation of MC3T3-E1 osteoblasts…”
BackgroundInfluentialAzadi, S., Yazdanpanah, M. A., Afshari, A., Alahdad, N., Chegeni, S., Angaji, A., Rezayat, S. M., & Tavakol, S. (2024) · Journal of Tissue Engineering · doi:10.1177/20417314241303818 · Cited by 24
Metadata
- Authors
- He, Y., Mu, C., Shen, X., Yuan, Z., Liu, J., Chen, W., Lin, C., Tao, B., Liu, B., & Cai, K.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 80
- Pages
- 412-424
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2892464396
- Cited by
- 86
- References
- 5
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.