Superparamagnetic iron oxides as MPI tracers: A primer and review of early applications
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Abstract
Magnetic particle imaging (MPI) has recently emerged as a non-invasive, whole body imaging technique that detects superparamagnetic iron oxide (SPIO) nanoparticles similar as those used in magnetic resonance imaging (MRI). Based on tracer “hot spot” detection instead of providing contrast on MRI scans, MPI has already proven to be truly quantitative. Without the presence of endogenous background signal, MPI can also be used in certain tissues where the endogenous MRI signal is too low to provide contrast. After an introduction to the history and simplified principles of MPI, this review focuses on early MPI applications including MPI cell tracking, multiplexed MPI, perfusion and tumor MPI, lung MPI, functional MPI, and MPI-guided hyperthermia. While it is too early to tell if MPI will become a mainstay imaging technique with the (theoretical) sensitivity that it promises, and if it can successfully compete with SPIO-based 1H MRI and perfluorocarbon-based 19F MRI, it provides unprecedented opportunities for exploring new nanoparticle-based imaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003 · cited 1×
“years later, in 2005, the scientific world first heard about MPI [2].”
BackgroundIron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500 · cited 1×
“It was realized that these nanosized magnetic entities change the microenvironment of the strong external magnetic fields, leading to a loss of phase coherence of resonating protons with as result a loss of MRI signal [8].”
BackgroundSelf-citationThree-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651 · cited 1×
“With the high temporal resolution of 40 frames per second for the FFP method, flowing blood can be observed in real-time in the heart [40] and the brain [38], and it is possible to obtain blood flow velocity measurements [41].”
MethodDynamic Imaging of Allogeneic Mesenchymal Stem Cells Trafficking to Myocardial Infarction
Kraitchman, D. L., Tatsumi, M., Gilson, W. D., Ishimori, T., Kedziorek, D., Walczak, P., Segars, W. P., H. Chen, H., Fritzges, D., Izbudak, I., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.537480 · Cited by 602 · cited 1×
“Systemically injected SPIO-labeled MSCs initially became entrapped within the lung vasculature, and then redistributed within one day to the liver and spleen (Figure 4)[21], which is a typical distribution pattern previously observed with single photon emission computed tomography (SPECT) of intravenously injected 111…”
BackgroundSelf-citationCheng, Y., Zhao, L., Li, Y., & Xu, T. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00097c · Cited by 515 · cited 1×
“This biological feature has previously been exploited to non-selectively target tumors with SPIO nanoparticles [45] and other nanosized contrast agents [46, 47] by means of the so-called enhanced permeability and retention (EPR) effect, leading to enhanced tumor MR images.”
BackgroundTracking immune cells in vivo using magnetic resonance imaging
Ahrens, E. T., & Bulte, J. W. M. (2013) · Nature Reviews Immunology · doi:10.1038/nri3531 · Cited by 491 · cited 1×
“Another example is imaging of inflammation, following intravenous injection of nanoparticles that accumulate in macrophages at the site of inflammation [11].”
BackgroundSelf-citationFluorine (19F) MRS and MRI in biomedicine
Ruiz‐Cabello, J., Barnett, B. P., Bottomley, P. A., & Bulte, J. W. M. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1570 · Cited by 489 · cited 1×
“While 19F MRI avoids the problems encountered with 1H MRI and has been successfully used for lung ventilation imaging using fluorous gases, it suffers in from low sensitivity [53].”
Self-citationTay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459 · cited 1×
“To proof this, localization of thermal damage and therapy was validated with luciferase activity and histological assessment [55].”
MethodIn vivo detection of single cells by MRI
Shapiro, E. M., Sharer, K., Skrtic, S., & Koretsky, A. P. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20718 · Cited by 378
Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection
Yu, E. Y., Bishop, M., Zheng, B., Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Krishnan, K. M., Goodwill, P. W., & Conolly, S. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04865 · Cited by 366 · cited 1×
“In another study, the tumor could be highlighted with a tumor-to-background ratio of up to 50 at the peak uptake of 6 hours after tracer injection [49].”
Background
Cited by
Recent progress of magnetic nanoparticles in biomedical applications: A review
Anik, M. I., Hossain, M. K., Hossain, I., Mahfuz, A. M. U. B., Rahman, M. T., & Ahmed, I. (2021) · Nano Select · doi:10.1002/nano.202000162 · Cited by 300
Magnetic Nanostructures: Rational Design and Fabrication Strategies toward Diverse Applications
Wang, S., Xu, J., Li, W., Sun, S., Gao, S., & Hou, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00370 · Cited by 129
Metadata
- Authors
- Bulte, J. W. M.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 138
- Pages
- 293-301
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2903992024
- Cited by
- 202
- References
- 68
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Superparamagnetic iron oxides as MPI tracers: A primer and review of early applications. https://app.cochat.ai/papers/10.1016/j.addr.2018.12.007
- The paper
- Bulte, J. W. M. (2019). Superparamagnetic iron oxides as MPI tracers: A primer and review of early applications. Advanced Drug Delivery Reviews. https://doi.org/10.1016/j.addr.2018.12.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.