Microneedles for advanced ocular drug delivery
Open accessThe DOI matches its Crossref record; 111 of the 111 references it cites were found in a registry or an index.
Abstract
In the field of ocular drug delivery, topical delivery remains the most common treatment option for managing anterior segment diseases, whileintraocular injectionsare the current gold standard treatment option for treating posterior segment diseases. Nonetheless, topical eye drops are associated with low bioavailability (<5%), and theintravitreal administration procedure is highly invasive, yielding poor patient acceptability. In both cases, frequent administration is currently required. As a result, there is a clear unmet need for sustained drug delivery to the eye, particularly in a manner that can be localised. Microneedles, which are patches containing an array of micron-scale needles (<1 mm), have the potential to meet this need. These platforms can enable localised drug delivery to the eye while enhancing penetration of drug molecules through key ocular barriers, thereby improving overall therapeutic outcomes. Moreover, the minimally invasive manner in which microneedles are applied could provide significant advantages over traditional intravitreal injections regarding patient acceptability. Considering the benefitsofthis novel ocular delivery system, this review provides an in-depth overviewofthe microneedle systems for ocular drug delivery, including the types of microneedles used and therapeutics delivered. Notably, we outline and discuss the current challenges associated with the clinical translation of these platforms and offer opinions on factors which should be considered to improve such transition from lab to clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026 · cited 2×
“[12,13,14,15,16,23,24,25,32,106,107,42,43,44,45,46,42,17, 19,18,47,49,50,51,52,53,19,54,23,55,56,57,58,59,60,61,53,23,49,62, 25,63,64,65,66,67,54,68,69,63].”
Ghasemi Falavarjani, K., & Nguyen, Q. D. (2013) · Eye · doi:10.1038/eye.2013.107 · Cited by 982 · cited 3×
“…to the target site, while the majority is cleared by the subconjunctival – episcleral blood and lymph vessel flow and the choriocapillaris blood flow and then absorbed into systemic circulation via the highly vascularised nasolacrimal duct, which can lead to adverse systemic effects [8,9].”
Vascular endothelial growth factor in eye disease
Penn, J. S., Madan, A., Caldwell, R. B., Bartoli, M., Caldwell, R. W., & Hartnett, M. E. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.05.001 · Cited by 762 · cited 2×
“All of these conditions are caused partly by a protein called VEGF, the overexpression of which not only promotes the generation of new, fragile vessels but also enhances the permeability of existing vessels, leading to blockages, leakage and hemorrhage [71].”
In vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724 · cited 1×
“Moreover, the thickness and density of collagen fibrils/fibers is also heterogeneous within the dermis, increasing from the thinner outermost papillary dermis to deeper into the skin toward the reticular dermis [131].”
Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708 · cited 1×
“Furthermore, dissolving microneedles offer design flexibility in that various patch sizes and geometries can be fabricated using a relatively straightforward and cost-effective micromold-casting method [30] .”
Self-citationEffect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701 · cited 1×
“The needle sizes of hollow microneedles, typically ranging from 27 to 35 gauge in outer diameter and starting from 150 µ m in length, are significantly smaller than those of conventional hypodermic needles (2 mm or more in length, 26 – 30 gauge) [36,37].”
A proposed model membrane and test method for microneedle insertion studies
Larrañeta, E., Moore, J., Vicente-Pérez, E. M., González-Vázquez, P., Lutton, R., Woolfson, A. D., & Donnelly, R. F. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.05.042 · Cited by 603
Self-citationRetinal nerve fiber layer analysis in the diagnosis of glaucoma
Zangwill, L. M., & Bowd, C. (2006) · Current Opinion in Ophthalmology · doi:10.1097/01.icu.0000193079.55240.18 · Cited by 595 · cited 1×
“Shields et al. demonstrated that the one-month application of corticosteroids via eye drops could significantly increase the intraocular pressure of 5% of patients to greater than 16 mmHg and 30% of patients to 6 – 16 mmHg [78].”
Lack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., McAllister, D. V., Smitra, S., Allen, M. G., & Prausnitz, M. R. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200102000-00041 · Cited by 576
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499 · cited 3×
“2) [16].”
Cited by
Natural Products from Herbal Medicine Self‐Assemble into Advanced Bioactive Materials
Guo, X., Luo, W., Wu, L., Zhang, L., Chen, Y., Li, T., Li, H., Zhang, W., Liu, Y., Zheng, J., et al. (2024) · Advanced Science · doi:10.1002/advs.202403388 · Cited by 240
Che, H., Xu, J., Wu, D., Chen, S., Liu, C., Zhao, C., & Peng, K. (2024) · Journal of Controlled Release · doi:10.1016/j.jconrel.2024.11.002 · Cited by 19
Metadata
- Authors
- Glover, K., Mishra, D., Gade, S., Vora, L. K., Wu, Y., Paredes, A. J., Donnelly, R. F., & Singh, T. R. R.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2023-10
- Volume
- 201
- Pages
- 115082
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W4386531277
- Cited by
- 169
- References
- 111
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.