The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Systematic review with meta-analysis of the accuracy of diagnostic tests for COVID-19
Open accessAbstract
Objective To collate the evidence on the accuracy parameters of all available diagnostic methods for detecting SARS-CoV-2. Methods A systematic review with meta-analysis was performed. Searches were conducted in Pubmed and Scopus (April 2020). Studies reporting data on sensitivity or specificity of diagnostic tests for COVID-19 using any human biological sample were included. Results Sixteen studies were evaluated. Meta-analysis showed that computed tomography has high sensitivity (91.9% [89.8%-93.7%]), but low specificity (25.1% [21.0%-29.5%]). The combination of IgM and IgG antibodies demonstrated promising results for both parameters (84.5% [82.2%-86.6%]; 91.6% [86.0%-95.4%], respectively). For RT-PCR tests, rectal stools/swab, urine, and plasma were less sensitive while sputum (97.2% [90.3%-99.7%]) presented higher sensitivity for detecting the virus. Conclusions RT-PCR remains the gold standard for the diagnosis of COVID-19 in sputum samples. However, the combination of different diagnostic tests is highly recommended to achieve adequate sensitivity and specificity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel coronavirus from patients with pneumonia in China, 2019
Zhu, N., Zhang, D., Wang, W., Li, X., Yang, B., Song, J., Zhao, X., Huang, B., Shi, W., Lu, R., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2001017 · Cited by 28,244
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Lauer, S. A., Grantz, K. H., Bi, Q., Jones, F. K., Zheng, Q., Meredith, H. R., Azman, A. S., Reich, N. G., & Lessler, J. (2020) · Annals of Internal Medicine · doi:10.7326/m20-0504 · Cited by 5,970
Antibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease 2019
Zhao, J., Yuan, Q., Wang, H., Liu, W., Liao, X., Su, Y., Wang, X., Yuan, J., Li, T., Li, J., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa344 · Cited by 2,607
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Registry of Arterial and Venous Thromboembolic Complications in Patients With COVID-19
Piazza, G., Campia, U., Hurwitz, S., Snyder, J. E., Rizzo, S. M., Pfeferman, M. B., Morrison, R. B., Leiva, O., Fanikos, J., Nauffal, V., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.070 · Cited by 292
Tsang, N. N. Y., So, H. C., Ng, K. Y., Cowling, B. J., Leung, G. M., & Ip, D. K. M. (2021) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(21)00146-8 · Cited by 287
Estimating SARS-CoV-2 infections from deaths, confirmed cases, tests, and random surveys
Irons, N. J., & Raftery, A. E. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2103272118 · Cited by 105
Metadata
- Authors
- Böger, B., Fachi, M. M., Vilhena, R. O., Cobre, A. F., Tonin, F. S., & Pontarolo, R.
- Venue
- American Journal of Infection Control
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 49
- Issue
- 1
- Pages
- 21-29
- ISSN
- 0196-6553 (ISSN-L)
- OpenAlex
- W3041626911
- Cited by
- 491
- References
- 4
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic review with meta-analysis of the accuracy of diagnostic tests for COVID-19. https://app.cochat.ai/papers/10.1016/j.ajic.2020.07.011
- The paper
- Böger, B., Fachi, M. M., Vilhena, R. O., Cobre, A. F., Tonin, F. S., & Pontarolo, R. (2021). Systematic review with meta-analysis of the accuracy of diagnostic tests for COVID-19. American Journal of Infection Control. https://doi.org/10.1016/j.ajic.2020.07.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.