The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Diagnostic performance of different sampling approaches for SARS-CoV-2 RT-PCR testing: a systematic review and meta-analysis
Open accessAbstract
Background The comparative performance of different clinical sampling methods for diagnosis of SARS-CoV-2 infection by RT-PCR among populations with suspected infection remains unclear. This meta-analysis aims to systematically compare the diagnostic performance of different clinical specimen collection methods. Methods In this systematic review and meta-analysis, we systematically searched PubMed, Embase, MEDLINE, Web of Science, medRxiv, bioRxiv, SSRN, and Research Square from Jan 1, 2000, to Nov 16, 2020. We included original clinical studies that examined the performance of nasopharyngeal swabs and any additional respiratory specimens for the diagnosis of SARS-CoV-2 infection among individuals presenting in ambulatory care. Studies without data on paired samples, or those that only examined different samples from confirmed SARS-CoV-2 cases were not useful for examining diagnostic performance of a test and were excluded. Diagnostic performance, including sensitivity, specificity, positive predictive value, and negative predictive value, was examined using random effects models and double arcsine transformation. Findings Of the 5577 studies identified in our search, 23 studies including 7973 participants with 16 762 respiratory samples were included. Respiratory specimens examined in these studies included 7973 nasopharyngeal swabs, 1622 nasal swabs, 6110 saliva samples, 338 throat swabs, and 719 pooled nasal and throat swabs. Using nasopharyngeal swabs as the gold standard, pooled nasal and throat swabs gave the highest sensitivity of 97% (95% CI 93–100), whereas lower sensitivities were achieved by saliva (85%, 75–93) and nasal swabs (86%, 77–93) and a much lower sensitivity by throat swabs (68%, 35–94). A comparably high positive predictive value was obtained by pooled nasal and throat (97%, 90–100) and nasal swabs (96%, 87–100) and a slightly lower positive predictive value by saliva (93%, 88–97). Throat swabs have the lowest positive predictive value of 75% (95% CI 45–96). Comparably high specificities (range 97–99%) and negative predictive value (range 95–99%) were observed among different clinical specimens. Comparison between health-care-worker collection and self-collection for pooled nasal and throat swabs and nasal swabs showed comparable diagnostic performance. No significant heterogeneity was observed in the analysis of pooled nasal and throat swabs and throat swabs, whereas moderate to substantial heterogeneity (I2 ≥30%) was observed in studies on saliva and nasal swabs. Interpretation Our review suggests that, compared with the gold standard of nasopharyngeal swabs, pooled nasal and throat swabs offered the best diagnostic performance of the alternative sampling approaches for diagnosis of SARS-CoV-2 infection in ambulatory care. Saliva and nasal swabs gave comparable and very good diagnostic performance and are clinically acceptable alternative specimen collection methods. Throat swabs gave a much lower sensitivity and positive predictive value and should not be recommended. Self-collection for pooled nasal and throat swabs and nasal swabs was not associated with any significant impairment of diagnostic accuracy. Our results also provide a useful reference framework for the proper interpretation of SARS-CoV-2 testing results using different clinical specimens. Funding Hong Kong Research Grants Council.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Ma, L.-L., Wang, Y.-Y., Yang, Z.-H., Huang, D., Weng, H., & Zeng, X.-T. (2020) · Military Medical Research · doi:10.1186/s40779-020-00238-8 · Cited by 1,648
A comparison of heterogeneity variance estimators in simulated random‐effects meta‐analyses
Langan, D., Higgins, J. P. T., Jackson, D., Bowden, J., Veroniki, A. A., Kontopantelis, E., Viechtbauer, W., & Simmonds, M. (2019) · Research Synthesis Methods · doi:10.1002/jrsm.1316 · Cited by 1,074
Immune response, inflammation, and the clinical spectrum of COVID-19
García, L. F. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.01441 · Cited by 739
False-negative results of initial RT-PCR assays for COVID-19: A systematic review
Arevalo-Rodriguez, I., Buitrago-Garcia, D., Simancas-Racines, D., Zambrano-Achig, P., Del Campo, R., Ciapponi, A., Sued, O., Martinez-García, L., Rutjes, A. W., Low, N., et al. (2020) · PLOS ONE · doi:10.1371/journal.pone.0242958 · Cited by 656
The Inverse of the Freeman – Tukey Double Arcsine Transformation
Miller, J. J. (1978) · The American Statistician · doi:10.1080/00031305.1978.10479283 · Cited by 535
Systematic review with meta-analysis of the accuracy of diagnostic tests for COVID-19
Böger, B., Fachi, M. M., Vilhena, R. O., Cobre, A. F., Tonin, F. S., & Pontarolo, R. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.07.011 · Cited by 491
Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy
Song, F., Khan, K. S., Dinnes, J., & Sutton, A. J. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.88 · Cited by 484
Cited by
Emerging COVID-19 variants and their impact on SARS-CoV-2 diagnosis, therapeutics and vaccines
Fernandes, Q., Inchakalody, V. P., Merhi, M., Mestiri, S., Taib, N., Moustafa Abo El-Ella, D., Bedhiafi, T., Raza, A., Al-Zaidan, L., Mohsen, M. O., et al. (2022) · Annals of Medicine · doi:10.1080/07853890.2022.2031274 · Cited by 447
Metadata
- Authors
- Tsang, N. N. Y., So, H. C., Ng, K. Y., Cowling, B. J., Leung, G. M., & Ip, D. K. M.
- Venue
- The Lancet Infectious Diseases
- Publisher
- Elsevier BV
- Published
- 2021-09
- Volume
- 21
- Issue
- 9
- Pages
- 1233-1245
- ISSN
- 1473-3099 (ISSN-L)
- OpenAlex
- W3153427680
- Cited by
- 287
- References
- 52
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic performance of different sampling approaches for SARS-CoV-2 RT-PCR testing: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/s1473-3099(21)00146-8
- The paper
- Tsang, N. N. Y., So, H. C., Ng, K. Y., Cowling, B. J., Leung, G. M., & Ip, D. K. M. (2021). Diagnostic performance of different sampling approaches for SARS-CoV-2 RT-PCR testing: a systematic review and meta-analysis. The Lancet Infectious Diseases. https://doi.org/10.1016/s1473-3099(21)00146-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.