Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Prospective evaluation of screening performance of first-trimester prediction models for preterm preeclampsia in an Asian population

Chaemsaithong, Piya, Pooh, Ritsuko K., Zheng, Mingming, Ma, Runmei, Chaiyasit, Noppadol, Tokunaka, Mayumi, Shaw, Steven W., Seshadri, Suresh, Choolani, Mahesh, Wataganara, Tuangsit, Yeo, George S.H., Wright, Alan, Leung, Wing Cheong, Sekizawa, Akihiko, Hu, Yali, Naruse, Katsuhiko, Saito, Shigeru, Sahota, Daljit, Leung, Tak Yeung, Poon, Liona C. · 2019 · American Journal of Obstetrics and Gynecology

Abstract

BACKGROUND The administration of aspirin <16 weeks' gestation to high risk women for preeclampsia (PE) has been shown to reduce the rate of preterm PE by 65%. The traditional approach to identify such women at risk is based on risk factors from maternal characteristics, obstetrics, and medical history as recommended by the American College of Obstetricians and Gynecologists (ACOG) and the National Institute for Health and Care Excellence (NICE). An alternative approach to screening for PE has been developed by the Fetal Medicine Foundation (FMF). This approach allows estimation of patient-specific risks of PE requiring delivery before a specified gestational age with the use of Bayes theorem-based model. OBJECTIVE To examine the diagnostic accuracy of the FMF Bayes theorem-based model, the ACOG and the NICE recommendations for the prediction of preterm PE at 11-13+6 weeks' gestation in a large Asian population METHODS: This was a prospective, non-intervention, multicenter study in 10,935 singleton pregnancies at 11-13+6 weeks' gestation in 11 recruiting centers across seven regions in Asia between December 2016 and June 2018. Maternal characteristics, medical, obstetric, and drug history were recorded. Mean arterial pressure (MAP) and uterine artery pulsatility index (UtA-PI) were measured according to standardized protocols. Maternal serum placental growth factor (PlGF) concentrations were measured by automated analyzers. The measured values of MAP, UtA-PI, and PlGF were converted into multiple of medians (MoMs). The FMF Bayes theorem-based model was used for the calculation of patient-specific risk of PE at <37 weeks (preterm PE) and at any gestation (all PE) in each participant. The performance of screening for preterm PE and all PE by a combination of maternal factors, MAP, UtA-PI, and PlGF (triple test) was evaluated with the adjustment of aspirin use. We examined the predictive performance of the model by the use of receiver operating characteristic curve and calibration by measurements of calibration slope and calibration-in-the large. The detection rate of screening by the FMF Bayes theorem-based model was compared to that derived from the application of ACOG and NICE recommendations. RESULTS There were 224 (2.05%) women that developed PE, including 73 cases (0.67%) of preterm PE. In pregnancies with preterm PE, the mean MoM values of MAP and UtA-PI were significantly higher (MAP: 1.099 vs. 1.008; p<0.001; UtA-PI: 1.188 vs 1.063; p=0.006), and the mean PlGF MoM was significantly lower (0.760 vs. 1.100; p<0.001) than in women without PE. The FMF triple test achieved detection rates of 48.2%, 64.0%, 71.8% and 75.8%, at 5%, 10%, 15% and 20% fixed false-positive rates, respectively, for the prediction of preterm PE. These were comparable to those of previously published data from the FMF study. Screening using ACOG recommendations achieved detection rate of 54.6% at 20.4% false-positive rate. The detection rate with the use of NICE guideline was 26.3% at 5.5% false-positive rate. CONCLUSION Based on a large number of women, this study has demonstrated that the FMF Bayes theorem-based model is effective in predicting preterm PE in Asian population and this method of screening is superior to the approach recommended by ACOG and NICE. We have also shown that the FMF prediction model can be implemented as part of routine prenatal care through the use of the existing infrastructure of routine prenatal care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajog.2019.09.041

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 169

Metadata

Authors
Chaemsaithong, P., Pooh, R. K., Zheng, M., Ma, R., Chaiyasit, N., Tokunaka, M., Shaw, S. W., Seshadri, S., Choolani, M., Wataganara, T., Yeo, G. S. H., Wright, A., Leung, W. C., Sekizawa, A., Hu, Y., Naruse, K., Saito, S., Sahota, D., Leung, T. Y., & Poon, L. C.
Venue
American Journal of Obstetrics and Gynecology
Publisher
Elsevier BV
Published
2019-12
Volume
221
Issue
6
Pages
650.e1-650.e16
ISSN
0002-9378 (ISSN-L)
OpenAlex
W2978654833
Cited by
169
References
12
FWCI
13.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective evaluation of screening performance of first-trimester prediction models for preterm preeclampsia in an Asian population. https://app.cochat.ai/papers/10.1016/j.ajog.2019.09.041
The paper
Chaemsaithong, P., Pooh, R. K., Zheng, M., Ma, R., Chaiyasit, N., Tokunaka, M., Shaw, S. W., Seshadri, S., Choolani, M., Wataganara, T., Yeo, G. S. H., Wright, A., Leung, W. C., Sekizawa, A., Hu, Y., Naruse, K., Saito, S., Sahota, D., Leung, T. Y., & Poon, L. C. (2019). Prospective evaluation of screening performance of first-trimester prediction models for preterm preeclampsia in an Asian population. American Journal of Obstetrics and Gynecology. https://doi.org/10.1016/j.ajog.2019.09.041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.