Predictive air-conditioner control for electric buses with passenger amount variation forecast☆
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract Air-conditioners (AC) usually consume the most electricity among all of the auxiliary components in an electric bus, over 30% of the battery power at maximum. On-board passengers carried by the electric bus are important but random heat sources, which are obsessional disturbances for the cabin temperature control and energy management of the AC system. This paper aims to improve the AC energy efficiency via passenger amount variation analysis and forecast in a model predictive control (MPC) framework. Three forecasting approaches are proposed to realize the passenger amount variation prediction in real-time, namely, stochastic prediction based on Monte Carlo, radial basis function neural network (RBF-NN) prediction, and Markov-chain prediction. A sample passenger number database along a typical bus line in Beijing is built for passenger variation pattern analysis and forecast. A comparative study of the above three prediction approaches with different prediction lengths (bus stops in this case) is conducted, from both the energy consumption and temperature control perspectives. A predictive AC controller is developed, and evaluated by comparing with Dynamic Programming (DP) and a commonly used rule-based control strategy. Simulation results show that all the three forecasting methods integrated within the MPC framework are able to achieve more stable temperature performance. The energy consumptions of MPC with Markov-chain prediction, RBF-NN forecast and Monte Carlo prediction are 6.01%, 5.88% and 5.81% lower than rule-based control, respectively, on the Beijing bus route studied in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The development and validation of a thermal model for the cabin of a vehicle
Marcos, D., Pino, F. J., Bordons, C., & Guerra, J. J. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.02.054 · Cited by 127
Energy-Optimal Control of an Automotive Air Conditioning System for Ancillary Load Reduction
Zhang, Q., Stockar, S., & Canova, M. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2418322 · Cited by 42
Cited by
Jia, C., Liu, W., He, H., & Chau, K. T. (2024) · Energy Conversion and Management · doi:10.1016/j.enconman.2024.119032 · Cited by 125
Self-citationThermal Management for the Cabin of a Battery Electric Vehicle Considering Passengers’ Comfort
Schaut, S., & Sawodny, O. (2020) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2019.2914888 · Cited by 97
Łebkowski, A. (2019) · Energies · doi:10.3390/en12050951 · Cited by 57
A two‐stage method for bus passenger load prediction using automatic passenger counting data
Wang, P., Chen, X., Chen, J., Hua, M., & Pu, Z. (2021) · IET Intelligent Transport Systems · doi:10.1049/itr2.12018 · Cited by 28
“First, most existing studies turn passenger load prediction into a time series problem and only use historical or current load data as predictors [19, 20, 23, 24].”
BackgroundMethod
Metadata
- Authors
- He, H., Yan, M., Sun, C., Peng, J., Li, M., & Jia, H.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 227
- Pages
- 249-261
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2751379472
- Cited by
- 80
- References
- 2
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.